Pular para o conteúdo
Merck
Todas as fotos(3)

Documentos Principais

435236

Sigma-Aldrich

Cellulose

microcrystalline, powder

Sinônimo(s):

Cellulose powder, Cotton linters

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Número CAS:
Número CE:
Número MDL:
Código UNSPSC:
12162002
NACRES:
NA.23
Preço e disponibilidade não estão disponíveis no momento.

Formulário

microcrystalline
powder

Nível de qualidade

tamanho de partícula

51 μm

pH

5-7 (11 wt. %)

densidade volumétrica

0.6 g/mL (25°C)

cadeia de caracteres SMILES

O1[C@H](C(C(C(C1CO)O)O)O)O[C@@H]2C(OC(C(C2O)O)O)CO

InChI

1S/C12H22O11/c13-1-3-5(15)6(16)9(19)12(22-3)23-10-4(2-14)21-11(20)8(18)7(10)17/h3-20H,1-2H2/t3?,4?,5?,6?,7?,8?,9?,10-,11?,12+/m1/s1

chave InChI

GUBGYTABKSRVRQ-WFVLMXAXSA-N

Procurando produtos similares? Visita Guia de comparação de produtos

Aplicação

Bulking agent, opacifier, anti-caking agent, extrusion aid and stabilizer for foams and emulsions.
High purity cellulose powders for partition chromatography.

Características e benefícios

Amorphous regions are hydrolyzed leaving crystalline microfibrils. Forms thixotropic gels, good thermal stability.

Código de classe de armazenamento

11 - Combustible Solids

Classe de risco de água (WGK)

WGK 1

Ponto de fulgor (°F)

Not applicable

Ponto de fulgor (°C)

Not applicable

Equipamento de proteção individual

Eyeshields, Gloves, type N95 (US)


Escolha uma das versões mais recentes:

Certificados de análise (COA)

Lot/Batch Number

Não está vendo a versão correta?

Se precisar de uma versão específica, você pode procurar um certificado específico pelo número do lote ou da remessa.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Os clientes também visualizaram

Slide 1 of 7

1 of 7

Hoang T M D Le et al.
PloS one, 16(2), e0247076-e0247076 (2021-02-12)
The effects of nutrient and mechanical sensing on gut motility and intestinal metabolism in lower vertebrates remains largely unknown. Here we present the transcriptome response to luminal stimulation by nutrients and an inert bolus on nutrient response pathways and also
Olof Regnell et al.
Ambio, 43(7), 878-890 (2014-01-15)
Methylation of mercury (Hg) to highly toxic methyl Hg (MeHg), a process known to occur when organic matter (OM) decomposition leads to anoxia, is considered a worldwide threat to aquatic ecosystems and human health. We measured temporal and spatial variations
Martin Bringmann et al.
Trends in plant science, 17(11), 666-674 (2012-07-13)
Directed plant cell growth is governed by deposition and alterations of cell wall components under turgor pressure. A key regulatory element of anisotropic growth, and hence cell shape, is the directional deposition of cellulose microfibrils. The microfibrils are synthesized by
Kevin C-Y Lee et al.
The ISME journal, 8(7), 1522-1533 (2014-01-31)
Most of the lineages of bacteria have remained unknown beyond environmental surveys using molecular markers. Until the recent characterisation of several strains, the phylum Armatimonadetes (formerly known as 'candidate division OP10') was a dominant and globally-distributed lineage within this 'uncultured
Inka Vanwonterghem et al.
The ISME journal, 8(10), 2015-2028 (2014-04-18)
A replicate long-term experiment was conducted using anaerobic digestion (AD) as a model process to determine the relative role of niche and neutral theory on microbial community assembly, and to link community dynamics to system performance. AD is performed by

Questions

1–9 of 9 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  3. Hello I'm looking for the molecular weight of this product with Cat. No. 435236 I was wondering if this info is provided in the data analysis? Thanks

    1 answer
    1. Unfortunately, the molecular weight of this product has not been determined.

      Helpful?

  4. Hello, I would like to know, is this MCC powder a fiber or particle?

    1 answer
    1. As mentioned in the 'PROPERTIES' section and on the lot specific Certificate of Analysis (COA), this product is offered in powered format. The particle size distribution is lot specific and reported in the Certificate. Please refer to Cellulose product numbers C6288 and S6790 should the fiber form be of interest.

      Helpful?

  5. Does 51um refer to the diameter or length of the particle?

    1 answer
    1. The particle size range for this product is reported on the lot-specific Certificate of Analysis with the specification being less than 10% at 250 um and greater than 40% being 74 um. The 51 um generally refers to the diameter, however this is the only particle size measure available.

      Helpful?

  6. Are all MCC on your portfolio extracted from wood pulp or are there other plant based MCCs as well?

    1 answer
    1. Source of origin information for Microcrystalline cellulose and other products is best provided on a product-specific, lot-specific basis via a Certificate of Origin (CofO). If the information on source is required prior to ordering, please contact your local Technical Service group to see which lot(s) would be available to you, and to see if CofOs are available.

      Helpful?

  7. From where it is extracted can u tell me details sir

    1 answer
    1. This product is extracted from wood pulp.

      Helpful?

  8. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?

  9. What is the particle size of the product 435236, Cellulose?

    1 answer
    1. The particle size for product 435236, Cellulose is 51 μm, per the supplier.

      Helpful?

Reviews

No rating value

Active Filters

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica