Accéder au contenu
Merck

Adsorption of water vapour from humid air in carbon molecular sieves: carbosieve S-III and carboxens 569, 1000 and 1001.

The Analyst (2003-03-11)
Patrycja Fastyn, Wojciech Kornacki, Malgorzata Kardaś, Janusz Gawlowski, Jan Niedzielski
RÉSUMÉ

The adsorption of water vapour in carbon molecular sieves (CMS) used to determine volatile organic compounds (VOCs) in air was investigated. The CMS mass in the trap was found not to affect the mass of retained water under conditions of incomplete saturation of the adsorbent bed with water. Thus, the restrictions commonly imposed on the CMS mass are not necessary. The usefulness of four different CMSs to sample large volumes of humid air was estimated. Carboxen 1000 exhibited the best performance. To assess the magnitude of CMS mass in the trap in dependence on the volume, the relative humidity and the temperature of the sample, the use of a novel parameter, called the water vapour interference factor, was suggested.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Supelco
Ensemble de fibres de SPME, divinylbenzène/carboxène/polydiméthylsiloxane (DVB/CAR/PDMS), matrix active group 50/30µm DVB/CAR/PDMS, needle size 24 ga, StableFlex fiber, for use with autosampler, fiber L 2 cm, pk of 3
Supelco
Ensemble de fibres de SPME, divinylbenzène/carboxène/polydiméthylsiloxane (DVB/CAR/PDMS), matrix active group 50/30µm DVB/CAR/PDMS, StableFlex fiber, manual holder, needle size 24 ga
Supelco
Ensemble de fibres de SPME, divinylbenzène/carboxène/polydiméthylsiloxane (DVB/CAR/PDMS), 50/30µm DVB/CAR/PDMS, StableFlex (1 cm), needle size 23 ga, Autosampler, pk of 3, plain gray hub
Supelco
ORBO 90, Carboxen® 564 (20/45), 160/80 mg, W,F,F separators, O.D. × L 6 mm × 75 mm, pkg of 25 ea, for analyte group MEK (methylethyl ketone)
Supelco
Ensemble de fibres de SPME, divinylbenzène/carboxène/polydiméthylsiloxane (DVB/CAR/PDMS), matrix active group 50/30µm DVB/CAR/PDMS, needle size 24 ga, StableFlex, for use with autosampler, fiber L 1 cm, pk of 3
Supelco
Ensemble de fibres de SPME, divinylbenzène/carboxène/polydiméthylsiloxane (DVB/CAR/PDMS), 50/30µm DVB/CAR/PDMS, StableFlex (2cm), needle size 23 ga, Autosampler, pk of 3, notched gray hub
Supelco
ORBO-78 400/200 MG PK/25, W,W,W separators, O.D. × L 6 mm × 110 mm, pkg of 25 ea
Supelco
Colonne capillaire Carboxen®-1010 PLOT pour GC/CPG, L × I.D. 30 m × 0.53 mm, average thickness 30 μm
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 75 μm(CAR/PDMS, for use with manual holder, needle size 24 ga
Supelco
Adsorbant Carboxen®, matrix Carboxen® 1000, 60-80 mesh, bottle of 10 g
Supelco
Colonne capillaire Carboxen®-1006 PLOT pour GC/CPG, L × I.D. 30 m × 0.53 mm, average thickness 30 μm
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 23 ga, StableFlex, for use with autosampler
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, StableFlex, for use with autosampler
Supelco
Colonne capillaire Carboxen®-1010 PLOT pour GC/CPG, L × I.D. 30 m × 0.32 mm, average thickness 15 μm
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 24 ga, for use with autosampler
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, for use with manual holder, StableFlex fiber
Supelco
Carbosieve Adsorbent, matrix Carbosieve S-III, 60-80 mesh, bottle of 10 g
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with autosampler
Supelco
Unité de fibres SPME, carboxène/polydiméthylsiloxane (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with manual holder
Supelco
Colonne capillaire Carboxen®-1006 PLOT pour GC/CPG, L × I.D. 30 m × 0.32 mm, average thickness 15 μm
Supelco
Ensemble de fibres de SPME, divinylbenzène/carboxène/polydiméthylsiloxane (DVB/CAR/PDMS), for use with autosampler, matrix active group 50/30µm DVB/CAR/PDMS, needle size 23 ga, metal alloy fiber, fiber L 2 cm
Supelco
Carboxen® 1000 Reversible SPE Tube, 200 mg/mL, pk 30
Supelco
Adsorbant Carboxen®, matrix Carboxen® 572, 20-45 mesh, bottle of 10 g
Supelco
Adsorbant Carboxen®, matrix Carboxen® 1000, 40-60 mesh, bottle of 50 g
Supelco
Tenax® TA / Carboxen® 1018, glass TD tube, preconditioned, O.D. × L 1/4 in. × 3 1/2 in., Sealed with (Swagelok® End-Fittings), pkg of 10 ea
Supelco
Adsorbant Carboxen®, matrix Carboxen® 569, 20-45 mesh, bottle of 10 g
Supelco
Adsorbant Carboxen®, matrix Carboxen® 1003, 40-60 mesh, bottle of 10 g
Supelco
Tube de sorbant ORBO-93, ORBO tube I.D. × L 6 mm × 95 mm, Bed A 180 mg, Bed B 90 mg, 60/80 mesh, pkg of 25 ea
Supelco
Carbosieve Adsorbent, matrix Carbosieve S-II, 60-80 mesh, bottle of 10 g
Supelco
Ensemble de fibres de SPME, divinylbenzène/carboxène/polydiméthylsiloxane (DVB/CAR/PDMS), matrix active group 50/30µm DVB/CAR/PDMS, needle size 23 ga, metal alloy fiber, for use with autosampler, fiber L 1 cm, pkg of 1 ×  ea