Accéder au contenu
Merck

Determination of Urinary PAH Metabolites Using DLLME Hyphenated to Injector Port Silylation and GC-MS-MS.

Journal of analytical toxicology (2015-04-08)
Manoj Kumar Gupta, Rajeev Jain, Pratibha Singh, Ratnasekhar Ch, Mohana Krishna Reddy Mudiam
RÉSUMÉ

Polycyclic aromatic hydrocarbons (PAHs) are ubiquitous environmental pollutants and well-known carcinogens. Hydroxy derivatives of PAH are considered as biomarkers of PAH exposure, and there is a need to measure these metabolites at low concentrations. So, a precise and eco-friendly analytical method has been developed for rapid determination of PAH metabolites. For the first time, a new analytical method based on coupling of dispersive liquid-liquid microextraction (DLLME) with auto-injector port silylation (auto-IPS) followed by gas chromatography-tandem mass spectrometry (GC-MS-MS) analysis is reported for the analysis of seven urinary PAH metabolites. Factors affecting DLLME and IPS, such as type and volume of extraction and disperser solvent, pH, ionic strength, injector port temperature, volume of N,O-bis(trimethylsilyl)trifluoroacetamide and type of solvent were investigated. Under optimized conditions, the limit of detection and limit of quantification were found to be in the range of 1-9 and 3-29 ng/mL, respectively. Satisfactory recoveries of metabolites in urine samples in the range of 87-95% were found. The developed method has been successfully applied for the determination of PAH metabolites in urine samples of exposed workers. DLLME-auto-IPS-GC-MS-MS method is time, labor, solvent and reagent saving, which can be routinely used for the analysis of urinary PAH metabolites.

MATÉRIAUX
Référence du produit
Marque
Description du produit

Sigma-Aldrich
Acétonitrile, anhydrous, 99.8%
Supelco
N,O-Bis(triméthylsilyl)trifluoroacétamide avec triméthylchlorosilane, with 1% trimethylchlorosilane, for GC derivatization, LiChropur
Sigma-Aldrich
Chlorotrimethylsilane, ≥98.0% (GC)
Sigma-Aldrich
Chlorotrimethylsilane, purified by redistillation, ≥99%
Sigma-Aldrich
N,O-Bis(triméthylsilyl)trifluoroacétamide, ≥99%
Sigma-Aldrich
Chlorobenzene, anhydrous, 99.8%
Sigma-Aldrich
Hexane, anhydrous, 95%
Sigma-Aldrich
Acétate d'éthyle, ≥99%, FCC, FG
Sigma-Aldrich
Acétate d'éthyle
Sigma-Aldrich
Chloroforme, anhydrous, contains amylenes as stabilizer, ≥99%
Sigma-Aldrich
Acétonitrile, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
Acétate d'éthyle, natural, ≥99%, FCC, FG
Sigma-Aldrich
Chloroforme, ≥99%, PCR Reagent, contains amylenes as stabilizer
Sigma-Aldrich
Chlorotrimethylsilane, produced by Wacker Chemie AG, Burghausen, Germany, ≥99.0% (GC)
Sigma-Aldrich
Tetrachloroethylene, anhydrous, ≥99%
Sigma-Aldrich
N-Acetyl-D-penicillamine, for HPLC derivatization, ≥99.0% (T)
Sigma-Aldrich
Acétate d'éthyle
Sigma-Aldrich
Méthanol, NMR reference standard
Sigma-Aldrich
Acétate d'éthyle, ReagentPlus®, ≥99.8%
Sigma-Aldrich
Dichlorométhane, suitable for HPLC, ≥99.9%, contains 40-150 ppm amylene as stabilizer
Sigma-Aldrich
Hexarelin, ≥90% (HPLC)
Sigma-Aldrich
Methanol solution, NMR reference standard, 4% in methanol-d4 (99.8 atom % D), NMR tube size 3 mm × 8 in.
Sigma-Aldrich
Chlorotrimethylsilane solution, 1.0 M in THF
Sigma-Aldrich
Methanol-12C, 99.95 atom % 12C
Sigma-Aldrich
Trichloroethylene, anhydrous, contains 40 ppm diisopropylamine as stabilizer, ≥99%
Sigma-Aldrich
Acétonitrile
Sigma-Aldrich
Methanol solution, (Methanol:Dimethyl sulfoxide 1:1 (v/v))