Accéder au contenu
Merck
Toutes les photos(6)

Documents

SCC626

Sigma-Aldrich

mEER Mouse E6/E7/hRas Oropharynx Epithelial Cell Line

new

Synonyme(s) :

HNSCC Cell Line, HPV E6/E7/hRas Cell Line, Mouse E6/E7/hRas Cell Line, OPSCC Cell Line, mEER Cell Line

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Code UNSPSC :
41106514
Nomenclature NACRES :
NA.81

Source biologique

mouse

Niveau de qualité

Conditionnement

vial of ≥1 x 10^6 vial (viable cells per vial)

Fabricant/nom de marque

Millipore

Technique(s)

cell culture | mammalian: suitable

Conditions d'expédition

liquid nitrogen

Température de stockage

−196°C

Description générale

SCC626, the mouse E6/E7/hRas (mEER) cell line, was established by the retroviral transduction of the HPV E6 gene, the HPV E7 gene, and the human hRas G12V gene into primary mouse oropharyngeal epithelial cells. It had been established that HPV E6 and E7 promote head and neck cancer.

Application

mEER cells are verified to be of mouse origin and negative for human, rat, Chinese hamster, Golden Syrian hamster, and non-human primate interspecies contamination, as assessed by a Contamination Clear panel by Charles River Animal Diagnostic ServicesCells tested negative for infectious diseases against a Mouse Essential CLEAR panel by Charles River Animal Diagnostic Services.Cells tested negative for mycoplasma.

Caractéristiques et avantages

The SCC626 mEER Mouse E6/E7/hRas Oropharynx Epithelial Cell Line is useful in the study of head and neck squamous cell carcinoma in an immunocompetent, syngeneic animal model.

Description de la cible

Head and neck cancers represent the sixth most common type of cancer. Among them, incidence of oropharyngeal squamous cell carcinoma (OPSCC) are on the rise, and a majority are driven by the human papilloma virus (HPV). While successful management methods exist, the local recurrence and the nodal metastasis result in mortality in some cases. Historically, insights into HPV-induced transformation have been obtained in the context of cervical cancer and anogenital warts models, and, while much of it is relevant to OPSCC, it is beneficial to have systems in which the effects of HPV infection can be studied in a context specific to OPSCC.​SOURCE SCC626 was established by the retroviral transduction of the HPV16 E6 gene, HPV16 E7 gene, and the human hRas gene into the primary oropharyngeal epithelial cells isolated from a male C57BL/6 mouse. mEER cells are the parent to mEERL cells and the MLMs were derived from lung metastases from a mouse with a mEERL tumor that got treatment (cisplatin/radiation) and had a recurrence. REFERENCES1.Kademani D. 2007. Oral cancer. Mayo Clin Proc. 82(7): 878-87. 2.Rogers SN, Brown JS, Woolgar JA, Lowe D, Magennis P, Shaw RJ, Sutton D, Errington D, Vaughan D. 2009. Survival following primary surgery for oral cancer. Oral Oncol. 45(3):201-11. 3.Pytynia KB, Dahlstrom KR, Sturgis EM. 2014. Epidemiology of HPV-associated oropharyngeal cancer. Oral Oncol. 50(5): 380-6. 4.Hoover AC, Spanos WC, Harris GF, Anderson ME, Klingelhutz AJ, Lee JH. 2007. The role of human papillomavirus 16 E6 in anchorage-independent and invasive growth of mouse tonsil epithelium. Arch Otolaryngol Head Neck Surg. 133(5): 495-502. 5.Williams R, Lee DW, Elzey BD, Anderson ME, Hostager BS, Lee JH. 2009. Preclinical models of HPV+ and HPV- HNSCC in mice: an immune clearance of HPV+ HNSCC. Head Neck. 31(7): 911-8. 6.Vermeer DW, Coppock JD, Zeng E, Lee KM, Spanos WC, Onken MD, Uppaluri R, Lee JH, Vermeer PD. 2016. Metastatic model of HPV+ oropharyngeal squamous cell carcinoma demonstrates heterogeneity in tumor metastasis. Oncotarget. 7(17): 24194-207.

Stockage et stabilité

mEER cells should be stored in liquid nitrogen until use. The cells can be cultured for at least 10 passages after initial thawing without significantly affecting the cell marker expression and functionality.

Autres remarques

This product is intended for sale and sold solely to academic institutions for internal academic research use per the terms of the “Academic Use Agreement” as detailed in the product documentation. For information regarding any other use, please contact licensing@milliporesigma.com.

Clause de non-responsabilité

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Code de la classe de stockage

10 - Combustible liquids

Classe de danger pour l'eau (WGK)

WGK 2

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique