EQCYTMAG-93K
MILLIPLEX® Equine Cytokine/Chemokine Magnetic Bead Panel - Immunology Multiplex Assay
The Equine Inflammation / Immunology Bead-Based Multiplex cytokine Assay kit, using the Luminex xMAP technology, enables the simultaneous analysis of 23 cytokine and chemokine biomarkers in equine serum, plasma and cell culture samples.
About This Item
Produits recommandés
Niveau de qualité
Espèces réactives
horse
Fabricant/nom de marque
Milliplex®
assay range
accuracy: 74%
(IL-17a)
accuracy: 76%
(IL-6)
accuracy: 78%
(FGF-2)
accuracy: 82%
(G-CSF)
accuracy: 83%
(IFNγ)
accuracy: 83%
(IL-12 (p70))
accuracy: 85%
(IL-13)
accuracy: 86%
(IL-10)
accuracy: 88%
(RANTES/CCL5)
accuracy: 89%
(IL-8/CXCL8)
accuracy: 90%
(IL-2)
accuracy: 90%
(MCP-1)
accuracy: 91%
(Fractalkine/CS3CL1)
accuracy: 92%
(IL-5)
accuracy: 93%
(Eotaxin/CCL11)
accuracy: 97%
(GRO)
sensitivity: 1.4 pg/mL
(IL-6)
sensitivity: 10.6 pg/mL
(IL-5)
sensitivity: 13.5 pg/mL
(IL-2)
sensitivity: 15.4 pg/mL
(IL-17A)
sensitivity: 16.3 pg/mL
(FGF-2)
sensitivity: 16.7 pg/mL
(IP-10)
sensitivity: 165 pg/mL
(IFNγ)
sensitivity: 25.3 pg/mL
(IL-18)
sensitivity: 29.3 pg/mL
(IL-1β)
sensitivity: 3.9 pg/mL
(RANTES/CCL5)
sensitivity: 3.94 pg/mL
(GM-CSF)
sensitivity: 340 pg/mL
(G-CSF)
sensitivity: 355 pg/mL
(IL-4)
sensitivity: 39-130 pg/mL
(IL-13)
sensitivity: 39.1 pg/mL
(IL-1α)
sensitivity: 399 ng/mL
(MCP-1)
sensitivity: 457 pg/mL
(Fractalkine/CS3CL1)
sensitivity: 49.2 pg/mL
(IL-12 (p70))
sensitivity: 5.2 pg/mL
(TNFα)
sensitivity: 62.5 pg/mL
(IL-10)
sensitivity: 7.8 pg/mL
(GRO)
sensitivity: 74.3 pg/mL
(IL-8/CXCL8)
sensitivity: 8.3 pg/mL
(Eotaxin/CCL11)
standard curve range: 15-15,000 pg/mL
(IL-17A)
standard curve range: 15-15,000 pg/mL
(IL-2)
standard curve range: 15-15,000 pg/mL
(IL-5)
standard curve range: 15-15,000 pg/mL
(IL-6)
standard curve range: 15-15,000 pg/mL
(IP-10)
standard curve range: 16.3 pg/mL
(FGF-2)
standard curve range: 29-30,000 pg/mL
(IL-1β)
standard curve range: 293-300,000 pg/mL
(IL-4)
standard curve range: 34-35,000 pg/mL
(IL-18)
standard curve range: 340 pg/mL
(G-CSF)
standard curve range: 342-350,000 ng/mL
(MCP-1)
standard curve range: 39-40,000 pg/mL
(IL-12 (p70))
standard curve range: 39-40,000 pg/mL
(IL-13)
standard curve range: 4-4,000 pg/mL
(TNFα)
standard curve range: 457 pg/mL
(Fractalkine/CS3CL1)
standard curve range: 488-500,000 pg/mL
(IFNγ)
standard curve range: 49-50,000 pg/mL
(IL-10)
standard curve range: 5-5,000 pg/mL
(GM-CSF)
standard curve range: 5-5,000 pg/mL
(RANTES/CCL5)
standard curve range: 59-60,000 pg/mL
(IL-1α)
standard curve range: 59-60,000 pg/mL
(IL-8/CXCL8)
standard curve range: 6-6,000 pg/mL
(GRO)
standard curve range: 8.3 pg/mL
(Eotaxin/CCL11)
Technique(s)
multiplexing: suitable
Méthode de détection
fluorometric (Luminex xMAP)
Conditions d'expédition
ambient
Catégories apparentées
Description générale
MILLIPLEX® Equine Cytokine/Chemokine Premix Panel is a 23-plex kit used for the simultaneous quantification of any or all the following analytes in equine serum, plasma, or culture supernatant samples: Eotaxin/CCL11, FGF-2, Fractalkine/CS3CL1, G-CSF, GM-CSF, GRO, IFN, IL-1α, IL-1β, IL-2, IL-4, IL-5, IL-6, IL-8/CXCL8, IL-10, IL-12 (p70), IL-13, IL-17a, IL-18, IP-10, MCP-1, RANTES/CCL5 and TNFα. This kit uses a 96-well format, contains a lyophilized standard cocktail, two internal assay quality controls and can measure up to 38 samples in duplicate.
The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.
Panel Type: Cytokines/Chemokines
Spécificité
Application
- Analytes: Eotaxin/CCL11, FGF-2, Fractalkine/CX3CL1, G-CSF, GM-CSF, GRO/KC, IFN-γ, IL-1α, IL-1β, IL-2, IL-4, IL-5, IL-6, IL-8, IL-10, IL-12 (p70), IL-13, IL-17A, IL-18, IP-10 (CXCL10), MCP-1, RANTES (CCL5), TNF-α
- Recommended Sample Type: Equine serum, plasma, tissue culture supernatant or tissue/cell extracts
- Recommended Sample Dilution: 25 μL per well of undiluted serum or plasma; tissue/cell culture samples may require dilution with an appropriate medium
- Assay Run Time: A primary incubation of 2 hours at room temperature (RT) (20-25°C), or for greater sensitivity, overnight (16-18 hours) at 2-8°C; followed by a 1 hour secondary incubation at RT
- Research Category: Inflammation & Immunology
Caractéristiques et avantages
Conditionnement
Stockage et stabilité
Informations légales
Clause de non-responsabilité
Mention d'avertissement
Danger
Mentions de danger
Classification des risques
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2
Organes cibles
Respiratory Tract
Code de la classe de stockage
10 - Combustible liquids
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Contenu apparenté
Discover benefits of using biomarker detection multiplex immunoassays for companion and agricultural animal health research and find vet med multiplex assays.
Discover the benefits of MILLIPLEX® multiplex assays, based on Luminex® xMAP® multiplex assay technology, that provide consistent, high-quality results and see how these multiplex biomarker Luminex® assays are being used to advance research.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique