Größe auswählen
| Ihnen/SKU | Verfügbarkeit | Preis |
|---|
Über diesen Artikel
Produktname
Pellicon® XL Kassette mit Biomax® Membran, Chemistry: Polyethersulfone (PES) Screen Type: A Device Size: 50 cm²
Quality Segment
material
polyethersulfone membrane, polypropylene , polypropylene screen
feature
holdup volume 3.2 mL
manufacturer/tradename
Pellicon®
parameter
0.03-0.05 L/min recirculation rate, 15 mL min. working volume, 2.8 bar max. transmembrane pressure (40 psig), 5.5 bar max. inlet pressure (80 psi) at 50 °C
technique(s)
analytical sample preparation: suitable, protein purification: suitable
L
18.8 cm (7.4 in.)
W
3 cm (1.2 in.)
filtration area
50 cm2
membrane nominal area
50 cm2
gravimetric extractables
≤7.5 mg/device
matrix
Biomax®
pore size
5 kDa NMWCO
pH
1-14
shipped in
ambient
General description
Features and Benefits
Packaging
Analysis Note
Other Notes
Legal Information
1 of 1
Dieser Artikel | |||
|---|---|---|---|
| pore size 5 kDa NMWCO | pore size 8 kDa NMWCO | pore size 100 kDa NMWCO | pore size 10 kDa NMWCO |
| technique(s) analytical sample preparation: suitable, protein purification: suitable | technique(s) analytical sample preparation: suitable, protein purification: suitable | technique(s) analytical sample preparation: suitable, protein purification: suitable | technique(s) analytical sample preparation: suitable, protein purification: suitable |
| filtration area 50 cm2 | filtration area 50 cm2 | filtration area 50 cm2 | filtration area 50 cm2 |
| matrix Biomax® | matrix Biomax® | matrix Biomax® | matrix Biomax® |
| material polyethersulfone membrane, polypropylene screen | material polyethersulfone membrane, polypropylene , polypropylene screen | material polyethersulfone membrane, polypropylene , polypropylene screen | material polyethersulfone membrane, polypropylene , polypropylene screen |
| parameter 0.03-0.05 L/min recirculation rate, 2.8 bar max. transmembrane pressure (40 psig), 15 mL min. working volume, 5.5 bar max. inlet pressure (80 psi) at 50 °C | parameter 0.03–0.05 L/min recirculation rate, 15 mL min. working volume, 2.8 bar max. transmembrane pressure (40 psig), 5.5 bar max. inlet pressure (80 psi) at 50 °C | parameter 0.03–0.05 L/min recirculation rate, 15 mL min. working volume, 2.8 bar max. transmembrane pressure (40 psig), 5.5 bar max. inlet pressure (80 psi) at 50 °C | parameter 0.03–0.05 L/min recirculation rate, 15 mL min. working volume, 2.8 bar max. transmembrane pressure (40 psig), 5.5 bar max. inlet pressure (80 psi) at 50 °C |
Still not finding the right product?
Explore all of our products under Pellicon® XL Kassette mit Biomax® Membran
Analysenzertifikate (COA)
Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.