KVEPS006FF3
Millipore Express® SHR, Opticap®-XL-Kapsel
Opticap® XL 600, sterile, inlet connection diam. 3/4 in., cartridge nominal length 6.5 in. (16.5 cm)
Synonym(e):
Opticap Sterile XL 600 Millipore Express SHR single layer 0.1 μm 3/4 in. TC/TC
About This Item
Empfohlene Produkte
Materialien
polyethersulfone
polyethylene support
polypropylene
polypropylene housing
polypropylene vent cap
silicone seal
Qualitätsniveau
Einhaltung gesetzlicher Vorschriften
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
Sterilität
irradiated
sterile
Produktlinie
Opticap® XL 600
Leistungsmerkmale
hydrophilic
Hersteller/Markenname
Millipore Express®
Parameter
≤5.8 mL/min air diffusion at 3.45 bar (50 psig) and 23 °C (in water)
1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
100 psi max. differential pressure (6.9 bar) (intermittent)
2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent)
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 23 °C
6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent)
6.9 bar max. inlet pressure (100 psi) at 23 °C (intermittent)
80 psi max. differential pressure (5.5 bar) (continuous)
80 psig max. inlet pressure
Methode(n)
sterile filtration: suitable
Länge
16.5 cm (6.5 in.)
Nennlänge Kartusche
6.5 in. (16.5 cm)
Durchmesser
5.6 cm (2.2 in.)
Filtrationsfläche
1010 cm2
Durchm. Einlassanschluss
3/4 in.
Breite Einlass bis Auslass
16.5 cm (6.5 in.)
Durchm. Auslassanschluss
3/4 in.
Verunreinigungen
≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
Matrix
Millipore Express® SHR
Porengröße
0.1 μm
Blasenpunkt
≥4000 mbar (58 psig), air with water at 23 °C
Fitting
1/4 in. drain/vent hose barb (with double O-ring Seal)
(19 mm (3/4 in.) Sanitary Flange Inlet and Outlet)
Allgemeine Beschreibung
Verpackung
Sonstige Hinweise
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Angaben zur Herstellung
3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
Hinweis zur Analyse
Quantitative Rückhaltung von Brevundimonas diminuta bei einer Mindestbeaufschlagung von 1 x 10⁷ KBE/cm² unter Anwendung der ASTM® F838-Methode.
After sterilization and a controlled water flush of 3.0 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.
Rechtliche Hinweise
Haftungsausschluss
Sie haben nicht das passende Produkt gefunden?
Probieren Sie unser Produkt-Auswahlhilfe. aus.
Analysenzertifikate (COA)
Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..
Setzen Sie sich mit dem technischen Dienst in Verbindung.