KPGEG1THH1
Millipore Express® PHF, Opticap® XLT Capsule
inlet connection diam. 5/8 in., Opticap® XLT 10, cartridge nominal length 10 in. (25 cm)
Synonym(e):
Opticap XLT 10 Millipore Express PHF Gamma Compatible 0.2 μm 5/8 in. HB
About This Item
Materialien
polyester support
polyethersulfone
polypropylene (gamma-stable)
polypropylene housing
polypropylene vent cap
polysulfone
silicone seal
Qualitätsniveau
Einhaltung gesetzlicher Vorschriften
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
Sterilität
irradiated
non-sterile
Kompatibilität mit Sterilisationsverfahren
gamma compatible
Produktlinie
Opticap® XLT 10
Leistungsmerkmale
gamma compatible
hydrophilic
Hersteller/Markenname
Millipore Express®
Parameter
≤32.7 mL/min air diffusion at 2.8 bar (40 psig) and 23 °C (in water)
1.0 bar max. inlet pressure (15 psi) at 80 °C
1000 bar max. differential pressure (15 psi) at 80 °C
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
5.5 bar max. inlet pressure (80 psi) at 25 °C
5500 mbar max. differential pressure (80 psi) at 25 °C
80 psig max. inlet pressure
Methode(n)
bioburden reduction: suitable
Länge
37.6 cm (14.8 in.)
Breite
7.8 in.
Nennlänge Kartusche
10 in. (25 cm)
Durchmesser
10.7 cm (4.2 in.)
Filtrationsfläche
0.57 m2
Durchm. Einlassanschluss
5/8 in.
Breite Einlass bis Auslass
19.8 cm (7.8 in.)
Durchm. Auslassanschluss
5/8 in.
Verunreinigungen
≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
Matrix
Millipore Express® PHF
Porengröße
0.2 μm
Fitting
1/4 in. drain/vent hose barb (with double O-ring seal)
inlet hose barb
outlet hose barb
(16 mm (5?8 in.) Hose Barb Inlet and Outlet)
Allgemeine Beschreibung
Verpackung
Sonstige Hinweise
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer wetting instructions of Filters with MILLIPORE EXPRESS® Membrane user guide
- Storage Statement: Please refer Filters with MILLIPORE EXPRESS® Membrane user guide
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Angaben zur Herstellung
Gamma compatible to 40 kGy; 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
Hinweis zur Analyse
Samples of membrane used in this filter were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
After sterilization and a controlled water flush of 11 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.
Rechtliche Hinweise
Haftungsausschluss
Sie haben nicht das passende Produkt gefunden?
Probieren Sie unser Produkt-Auswahlhilfe. aus.
Analysenzertifikate (COA)
Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..
Setzen Sie sich mit dem technischen Dienst in Verbindung.