Product 474487 is not assigned an expiration date or recommended retest date. Products with no expiration date or recommended retest date should be routinely inspected by customers to ensure they perform as expected. These products are also subject to a one-year warranty from the date of shipment. For more information, you may access the "Product Dating Information" document under "ADDITIONAL USEFUL DOCUMENTS ABOUT OUR PRODUCTS" at the bottom of the Quality Services page with this link: https://www.sigmaaldrich.com/life-science/quality-and-regulatory-management/quality-services.
Fortfahren mit
Größe auswählen
| Größe/SKU | Verfügbarkeit | Preis |
|---|---|---|
5 mL | Warenkorb auf Verfügbarkeit prüfen | € 113,00 |
25 mL | Warenkorb auf Verfügbarkeit prüfen | € 406,00 |
Über diesen Artikel
Quality Segment
assay
97%
contains
100 ppm tert-butylcatechol as inhibitor
refractive index
n20/D 1.337 (lit.)
bp
90 °C/4 mmHg (lit.)
density
1.637 g/mL at 25 °C (lit.)
storage temp.
2-8°C
SMILES string
FC(F)(F)C(F)(F)C(F)(F)C(F)(F)C(F)(F)C(F)(F)C(F)(F)C(F)(F)CCOC(=O)C=C
InChI
1S/C13H7F17O2/c1-2-5(31)32-4-3-6(14,15)7(16,17)8(18,19)9(20,21)10(22,23)11(24,25)12(26,27)13(28,29)30/h2H,1,3-4H2
InChI key
QUKRIOLKOHUUBM-UHFFFAOYSA-N
General description
Application
- As a monomer to synthesize block copolymer brushes of the [2-(methacryloyloxy)ethyl] trimethylammonium chloride (PMETAC) and poly(1H, 1H, 2H, 2H-perfluorodecyl Acrylate) (PPFDA). These polymer brushes can be used to reduce friction in microfluidic and biomedical devices.
- To prepare fluorinated block copolymers via chemical vapor deposition(CVD). These are highly transparent and hydrophobic films utilized as biocompatible coatings on optical glasses and commercial optical filters.
- As a precursor to synthesize poly(1H, 1H, 2H, 2H-perfluorodecyl acrylate) nanoparticles which can used as drug carriers and have the ability to cross the blood-brain barrier(BBB). They are utilized for the targeted transport of neuroprotective agents.
- To fabricate anti-fouling and anti-infective surface coating for medical textiles.
1 of 1
Dieser Artikel | |||
|---|---|---|---|
| description contains 100 ppm tert-butylcatechol as inhibitor, 97% | description certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland | description 97% | description 99% |
| assay 97% | assay - | assay 97% | assay 99% |
| storage temp. 2-8°C | storage temp. −20°C | storage temp. - | storage temp. - |
| density 1.637 g/mL at 25 °C (lit.) | density 1.637 g/mL at 25 °C (lit.) | density 1.678 g/mL at 25 °C | density 1.677 g/mL at 25 °C (lit.) |
| bp 90 °C/4 mmHg (lit.) | bp 90 °C/4 mmHg (lit.) | bp 82 °C/12 mmHg | bp - |
| refractive index n20/D 1.337 (lit.) | refractive index n20/D 1.337 (lit.) | refractive index n20/D 1.333 | refractive index n20/D 1.301 (lit.) |
| contains 100 ppm tert-butylcatechol as inhibitor | contains 0.01% 4-tert-Butylcatechol as stabilizer | contains - | contains - |
Still not finding the right product?
Explore all of our products under 1H,1H,2H,2H-Perfluordecylacrylat
Signalwort
Danger
Gefahrencodes
Hazard Classifications
Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Carc. 2 - Eye Dam. 1 - Lact. - Repr. 1B - STOT RE 1
Zielorgane
Liver
Lagerklasse
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
Was ist los?
WGK 3
Flammpunkt (°F)
235.4 °F - closed cup
Flammpunkt (°C)
113 °C - closed cup
PSA (Persönliche Schutzausrüstung)
Eyeshields, Gloves, type N95 (US)
Hier finden Sie alle aktuellen Versionen:
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
-
Does the Perfluorodecyl acrylate have a recommended retest or expiration date associated with the product?
1 answer-