Direkt zum Inhalt
Merck

427209

Sigma-Aldrich

Poly(ethylen-co-tetrafluorethylen)

melt index 11 g/10 min (279°C/49 newton), pellets

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

Lineare Formel:
(CH2CH2)x(CF2CF2)y
CAS-Nummer:
MDL-Nummer:
UNSPSC-Code:
12162002
PubChem Substanz-ID:
NACRES:
NA.23

Beschreibung

coefficient of friction 0.53 Dynamic, p=110 lbs,
velocity=0.08-0.35 cm/sec

Form

pellets

Schmelzindex

11 g/10 min (279°C/49 newton)

Härte

50-58 (Rockwell R, ASTM D 785)

Brechungsindex

n20/D 1.3

Übergangstemp.

brittleness temperature -125 °C (ASTM D 746)
Tm 250-270 °C (ASTM D 3418)

Dichte

1.73 g/mL at 25 °C (lit.)

SMILES String

C=C.F\C(F)=C(\F)F

InChI

1S/C2F4.C2H4/c3-1(4)2(5)6;1-2/h;1-2H2

InChIKey

QHSJIZLJUFMIFP-UHFFFAOYSA-N

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Anwendung

Injection molding and extrusion for wire coatings, tubes, films and monofilaments.

Leistungsmerkmale und Vorteile

Mechanical properties are superior to perfluorinated polymers like PTFE and PFA. Excellent performance over a wide temperature range and good electrical insulating properties over a wide temperature and frequency range.

Lagerklassenschlüssel

11 - Combustible Solids

WGK

WGK 3

Flammpunkt (°F)

Not applicable

Flammpunkt (°C)

Not applicable

Persönliche Schutzausrüstung

Eyeshields, Gloves, type N95 (US)


Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

Die passende Version wird nicht angezeigt?

Wenn Sie eine bestimmte Version benötigen, können Sie anhand der Lot- oder Chargennummer nach einem spezifischen Zertifikat suchen.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Kunden haben sich ebenfalls angesehen

M L Raimondi et al.
Journal of biomedical materials research, 29(1), 59-63 (1995-01-01)
The release behavior of typical commercial tissue expanders has been examined by carrying out two kinds of experiments: 1) Determination of chemical nature and its modification after in vivo use by X-ray photoelectron spectroscopy for chemical analysis. This study has
T Paulos et al.
Risk analysis : an official publication of the Society for Risk Analysis, 18(4), 471-510 (1998-10-17)
This paper investigates electrical overheating events aboard a habitable spacecraft. The wire insulation involved in these failures plays a major role in the entire event scenario from threat development to detection and damage assessment. Ideally, if models of wire overheating
Kristin J Pawlowski et al.
Frontiers in bioscience : a journal and virtual library, 9, 1412-1421 (2004-02-24)
Pioneers in the field of small diameter graft development sought to promote graft endothelialization and, thereby, increase patency by transplanting a varying degree of autologous endothelial cells onto vascular grafts prior to implantation. This process has become known as endothelial
Anthony G Gegauff et al.
Dental materials : official publication of the Academy of Dental Materials, 18(6), 479-485 (2002-07-06)
This pilot study was conducted to explore selected commercially-available thermoplastic composites that potentially had physical properties superior to currently available dental systems for restoring esthetic posterior crowns. Polyurethane, polycarbonate, and poly(ethylene/tetrafluoroethylene) (ETFE) composites and unfilled polyurethane specimens were injection molded
H Kaplan et al.
The Biochemical journal, 217(1), 135-143 (1984-01-01)
A modification to the competitive labelling procedure of Duggleby and Kaplan [(1975) Biochemistry 14, 5168-5175] was used to study the reactivity of the N-termini, lysine, histidine and tyrosine groups of insulin over the concentration range 1 X 10(-3)-1 X 10(-7)M.

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.