Accéder au contenu
Merck
Toutes les photos(1)

Documents

47528-U

Supelco

2-Isobutyl-3-methoxypyrazine solution

certified reference material

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Numéro CAS:
Code UNSPSC :
77101502
Nomenclature NACRES :
NA.24

Qualité

certified reference material
TraceCERT®

Niveau de qualité

Gamme de produits

TraceCERT®

CofA (certificat d'analyse)

current certificate can be downloaded

Conditionnement

ampule of 1 mL

Technique(s)

HPLC: suitable
gas chromatography (GC): suitable

Application(s)

environmental

Format

single component solution

Température de stockage

2-30°C

InChI

1S/C9H14N2O/c1-7(2)6-8-9(12-3)11-5-4-10-8/h4-5,7H,6H2,1-3H3

Clé InChI

UXFSPRAGHGMRSQ-UHFFFAOYSA-N

Application

Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.

Autres remarques

This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.

Informations légales

TraceCERT is a registered trademark of Merck KGaA, Darmstadt, Germany

Pictogrammes

FlameSkull and crossbonesHealth hazard

Mention d'avertissement

Danger

Classification des risques

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1

Organes cibles

Eyes

Code de la classe de stockage

3 - Flammable liquids

Classe de danger pour l'eau (WGK)

WGK 2

Point d'éclair (°F)

51.8 °F

Point d'éclair (°C)

11 °C

Équipement de protection individuelle

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

Vous ne trouvez pas la bonne version ?

Si vous avez besoin d'une version particulière, vous pouvez rechercher un certificat spécifique par le numéro de lot.

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Julie Roy et al.
Biophysical journal, 99(1), 218-226 (2010-07-27)
The mouse major urinary protein (MUP) has proved to be an intriguing test bed for detailed studies on protein-ligand recognition. NMR, calorimetric, and modeling investigations have revealed that the thermodynamics of ligand binding involve a complex interplay between competing enthalpic
Maria Staiano et al.
Biopolymers, 89(4), 284-291 (2007-12-22)
The effects of hydrostatic pressure on the structure and stability of porcine odorant-binding protein (pOBP) in the presence and absence of the odorant molecule 2-isobutyl-3-methoxypyrazine (IBMP) were studied by steady-state and time-resolved fluorescence spectroscopy as well as by molecular dynamics
Imelda Ryona et al.
Journal of agricultural and food chemistry, 56(22), 10838-10846 (2008-10-24)
The effects of light exposure on 3-isobutyl-2-methoxypyrazine (IBMP) accumulation and degradation in Vitis vinifera L. cv. Cabernet Franc berries were assessed by comparison of shaded and exposed clusters within the same vine throughout a growing season. Twenty-seven vines were shoot-thinned
Elizabeth Barratt et al.
Journal of the American Chemical Society, 127(33), 11827-11834 (2005-08-18)
In the present study we examine the enthalpy of binding of 2-methoxy-3-isobutylpyrazine (IBMP) to the mouse major urinary protein (MUP), using a combination of isothermal titration calorimetry (ITC), NMR, X-ray crystallography, all-atom molecular dynamics simulations, and site-directed mutagenesis. Global thermodynamics
Philippus Alberts et al.
Journal of agricultural and food chemistry, 57(20), 9347-9355 (2009-10-08)
An LC-MS/MS method for the trace-level determination of 3-alkyl-2-methoxypyrazines in Sauvignon blanc wines is described. 3-Isobutyl-2-methoxypyrazine (IBMP), 3-isopropyl-2-methoxypyrazine (IPMP) and 3-sec-butyl-2-methoxypyrazine (SBMP) were analyzed by reversed phase liquid chromatography coupled to atmospheric pressure chemical ionization, as electrospray ionization was found

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique