Saltar al contenido
MilliporeSigma

G7651

Sigma-Aldrich

Glutaraldehyde solution

Grade I, 50% in H2O, specially purified for use as an electron microscopy fixative or other sophisticated use

Sinónimos:

Glutaric dialdehyde solution, Pentane-1,5-dial

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización

Seleccione un Tamaño

10 ML
$112.00
10 X 10 ML
$533.00

$112.00


Check Cart for Availability

Solicitar un pedido a granel

Seleccione un Tamaño

Cambiar Vistas
10 ML
$112.00
10 X 10 ML
$533.00

About This Item

Fórmula lineal:
OHC(CH2)3CHO
Número de CAS:
Peso molecular:
100.12
Beilstein:
605390
Número MDL:
Código UNSPSC:
12352114
ID de la sustancia en PubChem:
NACRES:
NA.21

$112.00


Check Cart for Availability

Solicitar un pedido a granel

Nivel de calidad

tpo

Grade I

Formulario

liquid

concentración

50% in H2O

técnicas

electron microscopy: suitable (fixative)

color

colorless

mp

-21  °C ((-6 °F))

solubilidad

water: soluble

Condiciones de envío

dry ice

temp. de almacenamiento

−20°C

cadena SMILES

[H]C(CCCC([H])=O)=O

InChI

1S/C5H8O2/c6-4-2-1-3-5-7/h4-5H,1-3H2

Clave InChI

SXRSQZLOMIGNAQ-UHFFFAOYSA-N

¿Está buscando productos similares? Visita Guía de comparación de productos

Descripción general

Glutaraldehyde is a saturated dialdehyde, which is widely known as a chemical sterilant. Glutaraldehyde solutions comprise both monomers and polymers with a difference in their fixation efficiency. 

Aplicación

Glutaraldehyde solution has been used:
  • along with 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid (HEPES) buffer to fix the concentrated extracellular vesicles (EVs) on concanavalin A for scanning electron microscope (SEM)
  • as a component in a solution to fix the cells to observe its morphology
  • to fix the Escherichia coli cells in aqueous solution to preserve the surface morphology of bacterial cells

Acciones bioquímicas o fisiológicas

Glutaraldehyde is applicable in biomedical research to fix cells and can also be used to analyze healthy and pathologic red blood cells.

Características y beneficios

  • Highly efficient and safe to use with lensed instruments, rubber, or plastics 
  • Non-corrosive to metals
  • Minimum shelf life of 14 days

Otras notas

To gain a comprehensive understanding of our extensive range of Monosaccharides for your research, we encourage you to visit our Carbohydrates Category page.

Cláusula de descargo de responsabilidad

The product is not intended for use as a biocide under global biocide regulations, including but not limited to US EPA′s Federal Insecticide Fungicide and Rodenticide Act, European Biocidal Products Regulation, Canada’s Pest Management Regulatory Agency, Turkey’s Biocidal Products Regulation, Korea’s Consumer Chemical Products and Biocide Safety Management Act (K-BPR) and others.

Palabra de señalización

Danger

Clasificaciones de peligro

Acute Tox. 3 Inhalation - Acute Tox. 4 Oral - Aquatic Acute 1 - Aquatic Chronic 2 - Eye Dam. 1 - Resp. Sens. 1 - Skin Corr. 1B - Skin Sens. 1 - STOT SE 3

Órganos de actuación

Respiratory system

Riesgos supl.

Código de clase de almacenamiento

6.1A - Combustible acute toxic Cat. 1 and 2 / very toxic hazardous materials

Clase de riesgo para el agua (WGK)

WGK 3

Punto de inflamabilidad (°F)

Not applicable

Punto de inflamabilidad (°C)

Not applicable


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Irene Costantini et al.
Scientific reports, 5, 9808-9808 (2015-05-08)
Extensive mapping of neuronal connections in the central nervous system requires high-throughput µm-scale imaging of large volumes. In recent years, different approaches have been developed to overcome the limitations due to tissue light scattering. These methods are generally developed to
Stéphane Jauréguiberry et al.
Blood, 124(2), 167-175 (2014-05-27)
Patients with severe malaria treated with artesunate sometimes experience a delayed hemolytic episode. Artesunate (AS) induces pitting, a splenic process whereby dead parasites are expelled from their host erythrocytes. These once-infected erythrocytes then return to the circulation. We analyzed hematologic
Andri K Riau et al.
Investigative ophthalmology & visual science, 55(5), 3186-3194 (2014-04-26)
To compare flap adhesion strength, stromal bed quality, and tissue responses after flap preparation using nJ- and μJ-energy level femtosecond lasers. All corneal flaps were created by either VisuMax laser (μJ-energy level) or femto-LDV (nJ-energy level). Flap adhesion strength in
Stephanie J Bissel et al.
Journal of neuropathology and experimental neurology, 74(8), 767-777 (2015-06-27)
Human parechovirus 3 (HPeV3) is a picornavirus associated with neurologic disease in neonates. Human parechovirus 3 infection of preterm and term infants is associated with seizures and destructive periventricular white matter lesions. Despite unremarkable cerebrospinal fluid (CSF), HPeV3 RNA can
Jamie Hinks et al.
Applied and environmental microbiology, 81(6), 1949-1958 (2015-01-13)
The modification of microbial membranes to achieve biotechnological strain improvement with exogenous small molecules, such as oligopolyphenylenevinylene-conjugated oligoelectrolyte (OPV-COE) membrane insertion molecules (MIMs), is an emerging biotechnological field. Little is known about the interactions of OPV-COEs with their target, the

Contenido relacionado

Three-dimensional (3D) printing of biological tissue is rapidly becoming an integral part of tissue engineering.

Questions

1–2 of 2 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico