Saltar al contenido
MilliporeSigma

Saltar a

1.04148

Singlepath® Listeria monocytogenes kit

suitable for immunological and lateral flow essay testing in Food and Beverages application

Sinónimos:

Rapid L. Mono Food Test

Iniciar sesión para ver los precios por organización y contrato.

Seleccione un Tamaño

Cambiar Vistas
A ustedes/SKUDisponibilidadPrecio
25 test
Comprobar disponibilidad del carrito
$326.00

Acerca de este artículo

UNSPSC Code:
41116129
NACRES:
NA.24
Suitability:
Listeria monocytogenes
Manufacturer/tradename:
Singlepath®
Application(s):
food and beverages
pathogen testing
Technique(s):
lateral flow assay: suitable
Storage temp.:
2-8°C

$326.00


Comprobar disponibilidad del carrito

Solicitar más información
Servicio técnico
¿Necesita ayuda? Nuestro equipo de científicos experimentados está aquí para ayudarle.
Permítanos ayudarle


Nombre del producto

Singlepath® Listeria monocytogenes, suitable for lateral flow assay, for Listeria monocytogenes, input: food(s)

product line

Singlepath®

Quality Segment

form

solid

shelf life

15 mo.

packaging

pack of 25 strips

manufacturer/tradename

Singlepath®

technique(s)

lateral flow assay: suitable

input

sample type food(s)

application(s)

food and beverages
pathogen testing

storage temp.

2-8°C

suitability

Listeria monocytogenes

General description

Singlepath® Listeria monocytogenes is a rapid diagnostic test, designed to detect Listeria monocytogenes bacteria in various food samples. The Singlepath® Listeria monocytogenes is an immunochromatographic rapid test based on gold-labeled antibodies to detect the presence of a specific antigen, in this case, the L. monocytogenes bacteria. This lateral flow test is based on the immune flow principle and is a convenient and simple-to-use, one-step device. The test includes a nitrocellulose membrane strip that is coated with antibodies specific to L. monocytogenes antigens. When the sample is applied to the test strip, any L. monocytogenes antigens present will bind to the antibodies on the strip, resulting in the development of a visible test line. The test takes approximately 20 minutes to complete, and the results are interpreted based on the presence or absence of the test line. The lower detection limit can be considered as 5x106 bacteria/ml or one colony on an agar plate, depending on the serotype. No additional equipment expenditure is needed.

Application

Singlepath® Listeria monocytogenes can be used in industrial microbiology, to test a wide range of foods for Listeria monocytogenes using Listeria selective agars (e.g. PALCAM, Oxford, Chromoplate Listeria, Chromocult Listeria, etc.). This test can also be used for confirmation of suspect Listeria monocytogenes colonies on these agars.

Features and Benefits

  • Rapid and reliable method
  • High sensitivity and specificity compared to conventional culture methods
  • Can be performed without the need for specialized equipment or personnel.

Analysis Note

Performance test Antigen (Listeria monocytogenes Sv 1/2a EGD): passes test
Performance test Antigen (Listeria monocytogenes Sv 1/2c): passes test
Performance test Antigen (Listeria innocua ATCC 33090 (WDCM 00017)): passes test
Performance test Antigen (Listeria ivanovii ATCC 19119 (WDCM 00018)): passes test
Performance test Antigen (Escherichia coli ATCC 25922 (WDCM 00013)): passes test
Performance test Culture (Listeria monocytogenes Sv 1/2a EGD): passes test
Performance test Culture (Listeria innocua ATCC 33090 (WDCM 00017)): passes test
Performance test Culture (Listeria ivanovii ATCC 19119 (WDCM 00018)): passes test

Other Notes

Replaces: 1.04148.0002

Legal Information

SINGLEPATH is a registered trademark of Merck KGaA, Darmstadt, Germany

Comparar elementos similares

Ver comparación completa

Mostrar Diferencias

1 of 1

Este artículo
1.041411.041431.04140
manufacturer/tradename

Singlepath®

manufacturer/tradename

Singlepath®

manufacturer/tradename

Singlepath®

manufacturer/tradename

-

suitability

Listeria monocytogenes

suitability

Escherichia coli (O157), enterovirulent E. coli (EEC)

suitability

Campylobacter spp.

suitability

Citrobacter spp., Salmonella spp.

input

sample type food(s)

input

food(s)

input

sample type food(s)

input

food(s)

Quality Level

200

Quality Level

200

Quality Level

200

Quality Level

200

application(s)

food and beverages
pathogen testing

application(s)

food and beverages
pathogen testing

application(s)

food and beverages
pathogen testing

application(s)

food and beverages
pathogen testing

technique(s)

lateral flow assay: suitable

technique(s)

lateral flow assay: suitable, microbe id | immunological: suitable

technique(s)

lateral flow assay: suitable, microbe id | immunological: suitable

technique(s)

lateral flow assay: suitable, microbe id | immunological: suitable


Clase de almacenamiento

11 - Combustible Solids



Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos



Questions

Reviews

No rating value

Active Filters