Saltar al contenido
MilliporeSigma

182028

Sigma-Aldrich

Poly(ethylene oxide)

average MV 600,000 (nominal), powder, hydroxyl, BHT as inhibitor

Sinónimos:

Polyethylene oxide, PEO

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización

Seleccione un Tamaño

5 G
$54.63
250 G
$156.60
500 G
$263.15

$54.63

Precio de catálogo$60.70Ahorre 10 %
Web-Only Promotion

Disponible para envío el16 de abril de 2025Detalles


Solicitar un pedido a granel

Seleccione un Tamaño

Cambiar Vistas
5 G
$54.63
250 G
$156.60
500 G
$263.15

About This Item

Fórmula lineal:
(-CH2CH2O-)n
Número de CAS:
Número MDL:
Código UNSPSC:
12352104
ID de la sustancia en PubChem:
NACRES:
NA.23

$54.63

Precio de catálogo$60.70Ahorre 10 %
Web-Only Promotion

Disponible para envío el16 de abril de 2025Detalles


Solicitar un pedido a granel

Nombre del producto

Poly(ethylene oxide), average Mv 600,000 (nominal), powder

Formulario

powder

Nivel de calidad

mol peso

average Mv 600,000 (nominal)

contiene

200-500 ppm BHT as inhibitor

viscosidad

4,500-8,800 cP, 5 % in H2O(25 °C, Brookfield)(lit.)

temperatura de transición

Tm 65 °C

Ω-final

hydroxyl

α-final

hydroxyl

aplicaciones

battery manufacturing

cadena SMILES

[H]OCCO

InChI

1S/C2H6O2/c3-1-2-4/h3-4H,1-2H2

Clave InChI

LYCAIKOWRPUZTN-UHFFFAOYSA-N

¿Está buscando productos similares? Visita Guía de comparación de productos

Descripción general

Poly(ethylene oxide)(PEO) is a high molecular weight, non-ionic water-soluble polymer. It forms agel on hydration and shows good swelling capacity. PEO polymers are non-toxicand widely used in drug delivery systems to enhance drug solubility.

Aplicación

Poly(ethylene oxide) can be used to prepare:
  • Bioabsorbable and injectable hydrogels for sustained drug release.
  • PEO/graphene oxide composite electrolyte membrane for fuel cells.
  • Poly(ethylene oxide)-b-poly(ε-caprolactone) (PEO-b-PCL) diblock copolymer. Losartan potassium encapsulated (PEO-b-PCL) copolymer can be used as a drug carrier.

Código de clase de almacenamiento

11 - Combustible Solids

Clase de riesgo para el agua (WGK)

WGK 1

Punto de inflamabilidad (°F)

Not applicable

Punto de inflamabilidad (°C)

Not applicable

Equipo de protección personal

Eyeshields, Gloves, type N95 (US)


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Jun Li et al.
Journal of biomedical materials research. Part A, 65(2), 196-202 (2003-05-08)
Polymeric hydrogels long have attracted interest for biomaterials applications because of their generally favorable biocompatibility. High in water content, they are particularly attractive for delivery of delicate bioactive agents, such as proteins. However, because they require covalent crosslinking for gelation
Angeliki Chroni et al.
Nanomaterials (Basel, Switzerland), 10(9) (2020-09-24)
We report on the preparation of drug nanocarriers by encapsulating losartan potassium (LSR) into amphiphilic block copolymer micelles, utilizing the biocompatible/biodegradable poly(ethylene oxide)-b-poly(ε-caprolactone) (PEO-b-PCL) diblock copolymer. The PEO-b-PCL micelles and LSR-loaded PEO-b-PCL nanocarriers were prepared by organic solvent evaporation method
I L Konorova et al.
Patologicheskaia fiziologiia i eksperimental'naia terapiia, (4)(4), 7-9 (1991-07-01)
The search for antiaggregatory compounds is undertaken, as a rule, under in vitro conditions which do not reflect the dynamics of the real process. The present work deals with study of the peculiarities of the development of the collagen induced
D D Smyth et al.
Cardiovascular drugs and therapy, 4(1), 297-300 (1990-02-01)
Previous studies have demonstrated that Separan AP-30, a drag-reducing polymer, significantly decreased the formation of atherosclerotic plaques in rabbits fed a high-cholesterol diet. Furthermore, Separan AP-273, a polymer similar to but longer than Separan AP-30, markedly increased cardiac output in
M Patel Geeta et al.
Current drug delivery, 6(2), 159-165 (2009-05-20)
Carbamazepine indicated for the control of epilepsy, undergoes extensive hepatic first-pass metabolism after oral administration. A vaginal dosage form of carbamazepine is not commercially available. Conventional suppository having poor retention in the vaginal tract, as they are removed in a

Artículos

Electrospinning technique applications discussed, emphasizing control of nanofibers and assembly into 3D architectures.

Progress in biotechnology fields such as tissue engineering and drug delivery is accompanied by an increasing demand for diverse functional biomaterials. One class of biomaterials that has been the subject of intense research interest is hydrogels, because they closely mimic the natural environment of cells, both chemically and physically and therefore can be used as support to grow cells. This article specifically discusses poly(ethylene glycol) (PEG) hydrogels, which are good for biological applications because they do not generally elicit an immune response. PEGs offer a readily available, easy to modify polymer for widespread use in hydrogel fabrication, including 2D and 3D scaffold for tissue culture. The degradable linkages also enable a variety of applications for release of therapeutic agents.

Designing biomaterial scaffolds mimicking complex living tissue structures is crucial for tissue engineering and regenerative medicine advancements.

Questions

1–2 of 2 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico