跳轉至內容
Merck
  • High efficiency polyethylene glycol diacrylate monoliths for reversed-phase capillary liquid chromatography of small molecules.

High efficiency polyethylene glycol diacrylate monoliths for reversed-phase capillary liquid chromatography of small molecules.

Journal of chromatography. A (2014-09-07)
Pankaj Aggarwal, John S Lawson, H Dennis Tolley, Milton L Lee
摘要

Highly cross-linked monolithic networks (i.e., polyethylene glycol diacrylate, PEGDA) synthesized from monomers containing varying ethylene oxide chain lengths were fabricated inside fused silica capillary columns for use in liquid chromatography (LC) of small molecules. Tergitol was used as a surfactant porogen in combination with other typical organic liquid porogens. Column performance was correlated with quantitative descriptors of the physical/chemical properties of the monomers and porogens using a statistical model. Solubility and viscosity values of the components were identified as important predictors of monolith morphology and efficiency. The chromatographic retention mechanism was determined to be principally reversed-phase (RP) with additional hydrogen bonding between the polar groups of the analytes and the ethylene oxide groups embedded in the monolith structure. The fabricated monolithic columns were evaluated under RPLC conditions using phenols, hydroxy benzoic acids, and alkyl parabens as test compounds. Isocratic elution of hydroxy benzoic acids at a linear velocity of 0.04 cm/s using a PEGDA-700 monolith gave chromatographic peaks with little tailing (i.e., tailing factor<1.28). The chromatographic efficiency measured for a non-retained compound (uracil) using this column was 186,000 plates/m when corrected for injector dead volume. High resolution gradient separations of selected pharmaceutical compounds and phenylurea herbicides were achieved in less than 18 min. Optimized monoliths synthesized from all four crosslinking monomers exhibited high permeability and demonstrated little swelling or shrinking in different polarity solvents. Column preparation was highly reproducible, with relative standard deviation (RSD) values less than 2.1%, based on retention times of the phenol standards (3 different columns).

材料
產品編號
品牌
產品描述

Sigma-Aldrich
3-(三甲氧基甲硅基)甲基丙烯酸丙酯, 98%
Sigma-Aldrich
苯酚 溶液, Equilibrated with 10 mM Tris HCl, pH 8.0, 1 mM EDTA, BioReagent, for molecular biology
Sigma-Aldrich
没食子酸, 97.5-102.5% (titration)
Supelco
对羟基苯甲酸甲酯, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
对乙酰氨基酚, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
吲哚美辛, 98.5-100.5% (in accordance with EP)
USP
对乙酰氨基酚, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
4-羟基苯甲酸乙酯, ReagentPlus®, 99%
Sigma-Aldrich
2,2-二甲氧基-苯基苯乙酮, 99%
Supelco
羟苯丙酯, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
3-(三甲氧基甲硅基)甲基丙烯酸丙酯, ≥97%
USP
尼泊金甲酯, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
苯酚 溶液, BioReagent, Saturated with 0.01 M citrate buffer, pH 4.3 ± 0.2, for molecular biology
Sigma-Aldrich
水杨酸, ACS reagent, ≥99.0%
Sigma-Aldrich
苯酚, ≥99%
Sigma-Aldrich
苯酚, puriss. p.a., ACS reagent, reag. Ph. Eur., 99.0-100.5%
Supelco
水杨酸, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
3,4-二羟基苯甲酸, ≥97.0% (T)
Sigma-Aldrich
4-羟基苯甲酸丁酯, ≥99.0% (GC)
Sigma-Aldrich
4-羟基苯甲酸甲酯, ReagentPlus®, ≥99.0%, crystalline
Sigma-Aldrich
液状苯酚, ≥89.0%
Supelco
对羟基安息香甲酯, PESTANAL®, analytical standard
USP
4-羟基苯甲酸丙酯, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Resorcinol, ACS reagent, ≥99.0%
Sigma-Aldrich
苯酚, natural, 97%, FG
Sigma-Aldrich
对乙酰氨基酚, BioXtra, ≥99.0%
Sigma-Aldrich
间羟基苯甲酸, ReagentPlus®, 99%
Supelco
对羟基苯甲酸乙酯, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
水杨酸, ≥99%, FG
Sigma-Aldrich
苯酚, for molecular biology