Supelco

ProteoMass LTQ/FT-Hybrid ESI Pos. Mode Cal Mix

登入查看組織和合約定價


About This Item

分類程式碼代碼:
41116107
NACRES:
NA.24

產品線

ProteoMass

品質等級

CofA

current certificate can be downloaded

包裝

pkg of 1 × 10 mL

儲存條件

protect from light

濃度

(varied conc.)

技術

mass spectrometry (MS): suitable

形式

multi-component solution

運輸包裝

dry ice

儲存溫度

−20°C

尋找類似的產品? 前往 產品比較指南

一般說明

The ProteoMass ESI Calibration Kit for LTQ based Hybrids, positive ion mode calibration solution, enables calibration of Thermo Scientific hybrid instruments equipped with ESI source in positive ion mode. It covers a mass range from m/z 138 to m/z 1822, and is therefore usable for calibrations between m/z 50 and 2000.

應用

ProteoMass LTQ/FT-hybrid ESI Pos. mode cal mix has been used as a calibration standard for the mass spectrometric analysis of serum samples of patients affected by mugwort pollen allergy induced by pollen extract of Artemisia vulgaris.

特點和優勢

Discover the Advantages for Yourself!
  • Ready-to-use
  • Developed and qualified specifically for use with the LTQ based Thermo Scientific hybrid instruments (LTQ FT, LTQ FT Ultra, and LTQ Orbitrap series) with ESI source and Thermo Scientific Exactive
  • Conveniently packaged, freeing you from time consuming mixing and dilution steps, allowing you to focus on the acquistion of quality data

法律資訊

ProteoMass is a trademark of Sigma-Aldrich Co. LLC

訊號詞

Danger

危險分類

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Eye Irrit. 2 - Flam. Liq. 2 - STOT SE 1

標靶器官

Eyes,Central nervous system

儲存類別代碼

3 - Flammable liquids

水污染物質分類(WGK)

WGK 2

閃點(°F)

42.1 °F - closed cup

閃點(°C)

5.6 °C - closed cup


從最近期的版本中選擇一個:

分析證明 (COA)

Lot/Batch Number

未看到正確版本?

如果您需要一個特定的版本,您可以透過批號來尋找特定憑證。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

D Apostolovic et al.
Scientific reports, 7(1), 5201-5201 (2017-07-14)
The mammalian carbohydrate galactose-α1,3-galactose (α-Gal) causes a novel form of food allergy, red meat allergy, where patients experience severe allergic reactions several hours after red meat consumption. Here we explored gastric digestion of α-Gal glycoproteins using an in vitro model.
Robert J Strife et al.
Rapid communications in mass spectrometry : RCM, 24(11), 1497-1501 (2010-05-21)
Kendrick Mass Mapping of complex sample compositions, via data derived by Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS) at 1,000,000 resolution, is becoming more common. The Orbitrap mass spectrometer (Fourier Transform Axially Harmonic Orbital Trapping) also uses FT methods
Adam P Bateman et al.
Analytical chemistry, 82(19), 8010-8016 (2010-09-03)
This work demonstrates the utility of a particle-into-liquid sampler (PILS), a technique traditionally used for identification of inorganic ions present in ambient or laboratory aerosols, for the analysis of water-soluble organic aerosol (OA) using high-resolution electrospray ionization mass spectrometry (HR-ESI-MS).
Juan Chavez et al.
Chemical research in toxicology, 23(1), 37-47 (2010-01-02)
The protein targets and sites of modification by 4-hydroxy-2(E)-nonenal (HNE) in human monocytic THP-1 cells after exogenous exposure to HNE were examined using a multipronged proteomic approach involving electrophoretic, immunoblotting, and mass spectrometric methods. Immunoblot analysis using monoclonal anti-HNE antibodies
Peter A Eckert et al.
Analytical chemistry, 84(3), 1517-1525 (2011-12-15)
Nanospray desorption electrospray ionization (nano-DESI) combined with high-resolution mass spectrometry was used for the first time for the analysis of the polar constituents of liquid petroleum crude oil samples. The analysis was performed in both positive and negative ionization modes

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務