跳轉至內容
Merck
全部照片(1)

文件

50813-U

Supelco

Ascentis™ Express 90 Å C18 (2 μm) HPLC Columns

L × I.D. 10 cm × 2.1 mm UHPLC Column

登入查看組織和合約定價


About This Item

分類程式碼代碼:
41115700
NACRES:
SB.52

product name

Ascentis® Express C18, 2 μm UHPLC 色谱柱, 2 μm particle size, L × I.D. 10 cm × 2.1 mm

材料

stainless steel column

agency

suitable for USP L1

產品線

Ascentis®

特點

endcapped

製造商/商標名

Ascentis®

包裝

1 ea of

參數

1000 bar max. pressure (14500 psi)
60 °C temp. range

技術

HPLC: suitable
LC/MS: suitable
UHPLC-MS: suitable
UHPLC: suitable

長度 × 內徑

10 cm × 2.1 mm

表面積

120 m2/g

雜質

<5 ppm metals

基質

Fused-Core particle platform
superficially porous particle

基質活性組

C18 (octadecyl) phase

粒徑

2 μm

孔徑

90 Å pore size

工作pH值

2-9

應用

food and beverages

分離技術

reversed phase

尋找類似的產品? 前往 產品比較指南

相關類別

推薦產品

探索最适于 HPLCLC-MS 分析的 LiChropur 试剂

法律資訊

Ascentis is a registered trademark of Merck KGaA, Darmstadt, Germany

Choose from one of the most recent versions:

分析證明 (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

Pankaj Partani et al.
Journal of chromatographic science, 54(8), 1385-1396 (2016-05-27)
A liquid chromatography-tandem mass spectrometry method was developed and validated for the simultaneous determination of simvastatin (SV) and simvastatin acid (SVA) in human plasma. To improve assay sensitivity and achieve simultaneous analysis, SVA monitored in (-)ESI (electrospray ionization) mode within
Francesco Pio Prencipe et al.
Journal of chromatography. A, 1349, 50-59 (2014-05-27)
The study was aimed at developing a new analytical method for the metabolite fingerprinting of bioactive compounds in Humulus lupulus L. (hop), together with a simple extraction procedure. Different extraction techniques, including maceration, heat reflux extraction (HRE), ultrasound-assisted extraction (UAE)
Silvia Jakabová et al.
Journal of chromatography. A, 1232, 295-301 (2012-03-07)
Hyoscyamine (atropine) and scopolamine are the predominant tropane alkaloids in the Datura genus, occurring in all plant organs. The assessment of the alkaloid content of various plant parts is essential from the viewpoint of medical use, but also as a
Heena et al.
Journal of chromatographic science, 53(5), 800-806 (2014-10-18)
This study represents a new analytical high-performance liquid chromatography-fluorescence detector method for the determination of Al(III) as Al(III) complex with 8-hydroxyquinoline-5-sulfonic acid in a tap water sample and a coke sample. A micellar liquid chromatographic method is proposed for the
Ahmed Abrahim et al.
Journal of pharmaceutical and biomedical analysis, 51(1), 131-137 (2009-09-18)
Fused-core silica stationary phases represent a key technological advancement in the arena of fast HPLC separations. These phases are made by fusing a 0.5 microm porous silica layer onto 1.7 microm nonporous silica cores. The reduced intra-particle flow path of

文章

Dual-layer cartridge achieves efficient SPE clean-up for challenging pesticide residue testing in turmeric and spices.

LC/LC-MS method identifies 8 aminoglycosides in pork using Discovery® DSC-18 SPE and Ascentis® Express C18 UHPLC, per Chinese standards.

2-layer SPE cartridge efficiently reduces background for ginger contaminant analysis.

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務