Parker® Chromgas® 零空气发生器

Model 1000, 110 volt, output flow, 1000 cc/min

登入查看組織和合約定價


About This Item

分類程式碼代碼:
41112500

特點

output flow 1000 cc/min

尋找類似的產品? 前往 產品比較指南

一般說明

This ChromGas zero air generator incorporates three stages:
  • A 0.5 mm coalescing inlet filter removes particles, oil, and water
  • A heated catalyst removes hydrocarbons
  • A 0.01 mm cellulose fiber outlet filter removes residual particulate material from the product air stream
A hazard-free and economical alternative to high pressure gas cylinders, this unit should pay for itself in a year or two.

Features/Benefits
  • Eliminates need for expensive gas cylinders
  • Compact; requires less than one square foot of bench space
  • Can be used anywhere that an electrical supply is available
  • Only requires an upstream compressed air source

Maintenance
  • Clean the inlet and outlet filters every six months
  • Change the inlet and outlet filters every two years

Specifications
  • Inlet Pressure: 2-125 psig
  • Outlet Purity: <0.1 ppm hydrocarbons (as methane)
  • Outlet Pressure: 125 psig
  • Outlet Fitting: 1/8 in. compression
  • Power Needs: 110 V (60 Hz), or 230 V (50 Hz)
  • Shipping Weight (Model 1000 and 1001): 11 lb (5 Kg)
  • Shipping Weight (Model 3500 and 3501): 20 lb (9.1 Kg)
  • Dimensions (Model 1000 and 1001; H x W x D): 9.75 in. x 5.75 in. x 12 in. (25 cm x 14.7 cm x 30.8 cm)
  • Dimensions (Model 3500 and 3501; H x W x D): 12 in. x 6.75 in. x 15 in. (29.2 cm x 17.8 cm x 39.4 cm)

Marks
  • CE approved
  • UL listed
  • CSA listed
  • IEC 1010 certified

應用

Catalytic Zero air generator may be used to measure zero air count rates after field measurements, to determine atmospheric concentrations of volatile organic compound using On-line proton transfer reaction-mass spectrometry (PTR-MS). It may also be used to obtain volatile organic compound-air which could be used to dilute the standard gas to 50 ppb required to calibrate PTR-MS.

法律資訊

Chromgas is a registered trademark of Parker Hannifin
Parker is a registered trademark of Parker Hannifin

Choose from one of the most recent versions:

分析證明 (COA)

Lot/Batch Number

Sorry, we don't have COAs for this product available online at this time.

If you need assistance, please contact 客戶支援

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

Hydrocarbon fluxes above a Scots pine forest canopy: measurements and modeling.
Rinne, J., et al.
Atmospheric Chemistry and Physics, 7, 3361-3372 (2007)
On-line PTR-MS measurements of atmospheric concentrations of volatile organic compounds in a European boreal forest ecosystem.
Rinne, Janne, et al.
Boreal Environment Research, 10, 425-436 (2005)

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務