S3125

Sigma-Aldrich

癸二酸二(2-乙基己基)酯

~95%

同義詞:

二(2-乙基己基)癸二酸酯, 癸二酸二(2-乙基己基)酯, 癸二酸二辛酯

登入查看組織和合約定價


About This Item

線性公式:
[-(CH2)4CO2CH2CH(C2H5)(CH2)3CH3]2
CAS號碼:
分子量::
426.67
Beilstein:
1806504
EC號碼:
MDL號碼:
分類程式碼代碼:
12352211

化驗

~95%

折射率

n20/D 1.450 (lit.)

bp

212 °C/1 mmHg (lit.)

密度

0.914 g/mL at 25 °C (lit.)

儲存溫度

2-8°C

SMILES 字串

CCCCC(CC)COC(=O)CCCCCCCCC(=O)OCC(CC)CCCC

InChI

1S/C26H50O4/c1-5-9-17-23(7-3)21-29-25(27)19-15-13-11-12-14-16-20-26(28)30-22-24(8-4)18-10-6-2/h23-24H,5-22H2,1-4H3

InChI 密鑰

VJHINFRRDQUWOJ-UHFFFAOYSA-N

尋找類似的產品? 前往 產品比較指南

取代透過

產品號碼
描述
訂價

儲存類別代碼

10 - Combustible liquids

水污染物質分類(WGK)

awg

個人防護裝備

Eyeshields, Gloves


從最近期的版本中選擇一個:

分析證明 (COA)

Lot/Batch Number

未看到正確版本?

如果您需要一個特定的版本,您可以透過批號來尋找特定憑證。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

D Oesterle et al.
Journal of cancer research and clinical oncology, 114(2), 133-136 (1988-01-01)
The plasticizer DEHP but not DEHS exerted a weak promoting effect in a 12-week rat liver foci bioassay, using weanling female Sprague-Dawley rats. The effect was similar after doses of 200 and 500 mg/kg body weight, given 3 times weekly
Kevin R Wilson et al.
Physical chemistry chemical physics : PCCP, 14(4), 1468-1479 (2011-12-14)
The heterogeneous reactions of hydroxyl radicals (OH) with squalane and bis(2-ethylhexyl) sebacate (BES) particles are used as model systems to examine how distributions of reaction products evolve during the oxidation of chemically reduced organic aerosol. A kinetic model of multigenerational
Nedime Dürüst et al.
Analytica chimica acta, 699(1), 107-112 (2011-06-28)
Polycation-sensitive membrane optodes based on the chromoionophore 2',7'-dichlorofluorescein octadecylester (DCFOE) have previously been developed and used for determination of heparin via a titrimetric method. In this study, it is shown that some other important polyanions such as PPS (pentosan polysulfate)
M Kohlhäufl et al.
American journal of respiratory and critical care medicine, 159(3), 902-906 (1999-03-02)
Previous studies suggest that lung function tests using monodisperse aerosols can help to identify early stages of lung diseases. We investigated intrapulmonary particle loss and aerosol bolus dispersion-a marker of convective gas transport-in 32 women with asymptomatic nonspecific bronchial hyperresponsiveness
C S Kim et al.
Journal of applied physiology (Bethesda, Md. : 1985), 81(5), 2203-2213 (1996-11-01)
Detailed regional deposition of inhaled particles was investigated in young adults (n = 11) by use of a serial bolus aerosol delivery technique. A small bolus (45 ml half-width) of monodisperse aerosols [1-, 3-, and 5-microns particle diameter (Dp)] was