推薦產品
品質等級
物種活性
human
包裝
kit of 96 wells (12 strips x 8 wells)
技術
ELISA: suitable
capture ELISA: suitable
輸入
sample type serum
sample type plasma
sample type cell culture supernatant(s)
sample type urine
assay range
inter-assay cv: <12%
intra-assay cv: <10%
sensitivity: 15 pg/mL
standard curve range: 8.23-6000 pg/mL
檢測方法
colorimetric
運輸包裝
wet ice
儲存溫度
−20°C
基因資訊
human ... PECAM1(18613)
一般說明
The Human PECAM-1 ELISA (Enzyme-Linked Immunosorbent Assay) kit is an in vitro enzyme-linked immunosorbent assay for the quantitative measurement of human PECAM-1 in serum, plasma, cell culture supernatants and urine.
免疫原
Recombinant Human PECAM1
應用
请参考Protocol了解详情。
其他說明
A sample Certificate of Analysis is available for this product.
Please type the word sample in the text box provided for lot number.
Please type the word sample in the text box provided for lot number.
訊號詞
Warning
危險聲明
防範說明
危險分類
Met. Corr. 1
儲存類別代碼
8A - Combustible corrosive hazardous materials
Zhen Yan et al.
International journal of nanomedicine, 12, 4433-4442 (2017-06-28)
Engineered zinc oxide nanoparticles (ZnO-NPs) are currently being produced in high tonnage. Exposure to ZnO-NPs presents potential risks to cardiovascular system. Thus far, the toxicological effects of ZnO-NPs on cardiovascular system have not been well characterized. In this study, human
Huiwen Jiang et al.
Annals of hematology, 98(7), 1721-1732 (2019-05-06)
The CD19-targeted chimeric antigen receptor T cell (CAR-T) therapy has been widely proved effective on relapsed and refractory (r/r) B cell acute lymphoblastic leukemia (B-ALL). Meanwhile, CAR-T therapy-related toxicities, including cytokine release syndrome (CRS) and neurological toxicities, are drawing researchers'
Joerg Kellermair et al.
Journal of thrombosis and thrombolysis, 50(2), 380-385 (2020-03-28)
D-Dimer has a high sensitivity but a low specificity for the diagnosis of deep vein thrombosis (DVT) which limits its implementation as a general screening parameter. There is a demand for additional biomarkers to improve its diagnostic accuracy. Soluble platelet
Andrei A Karpov et al.
International journal of molecular sciences, 22(3) (2021-01-28)
Chronic thromboembolic pulmonary hypertension (CTEPH) is a rare and life-threatening complication of pulmonary embolism. As existing animal models of CTEPH do not fully recapitulate complex disease pathophysiology, we report a new rat model for CTEPH evoked by repetitive embolization of
Claudia Strobel et al.
Beilstein journal of nanotechnology, 5, 1795-1807 (2014-11-11)
Cerium dioxide (CeO2) and silicon dioxide (SiO2) nanoparticles are of widespread use in modern life. This means that human beings are markedly exposed to them in their everyday life. Once passing biological barriers, these nanoparticles are expected to interact with
我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.
聯絡技術服務