跳轉至內容
Merck
全部照片(2)

重要文件

RAB0401

Sigma-Aldrich

人类 PECAM-1 ELISA 试剂盒

for serum, plasma, cell culture supernatants and urine

登入查看組織和合約定價


About This Item

分類程式碼代碼:
41116158
NACRES:
NA.32

品質等級

物種活性

human

包裝

kit of 96 wells (12 strips x 8 wells)

技術

ELISA: suitable
capture ELISA: suitable

輸入

sample type serum
sample type plasma
sample type cell culture supernatant(s)
sample type urine

assay range

inter-assay cv: <12%
intra-assay cv: <10%
sensitivity: 15 pg/mL
standard curve range: 8.23-6000 pg/mL

檢測方法

colorimetric

運輸包裝

wet ice

儲存溫度

−20°C

基因資訊

human ... PECAM1(18613)

一般說明

The Human PECAM-1 ELISA (Enzyme-Linked Immunosorbent Assay) kit is an in vitro enzyme-linked immunosorbent assay for the quantitative measurement of human PECAM-1 in serum, plasma, cell culture supernatants and urine.

免疫原

Recombinant Human PECAM1

應用

请参考Protocol了解详情。

其他說明

A sample Certificate of Analysis is available for this product.
Please type the word sample in the text box provided for lot number.

套裝中的組件也可單獨購買

產品號碼
描述
SDS

  • RABELADAELISA 1X Assay/Sample Diluent Buffer A (Item D1)SDS

  • RABELADBELISA 5X Assay/Sample Diluent Buffer B (Item E1)SDS

  • RABSTOP3ELISA Stop Solution (Item I)SDS

  • RABTMB3ELISA Colorimetric TMB Reagent (HRP Substrate, Item H)SDS

  • RABWASH420X Wash Buffer (Item B)SDS

象形圖

Corrosion

訊號詞

Warning

危險聲明

防範說明

危險分類

Met. Corr. 1

儲存類別代碼

8A - Combustible corrosive hazardous materials


從最近期的版本中選擇一個:

分析證明 (COA)

Lot/Batch Number

未看到正確版本?

如果您需要一個特定的版本,您可以透過批號來尋找特定憑證。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

Zhen Yan et al.
International journal of nanomedicine, 12, 4433-4442 (2017-06-28)
Engineered zinc oxide nanoparticles (ZnO-NPs) are currently being produced in high tonnage. Exposure to ZnO-NPs presents potential risks to cardiovascular system. Thus far, the toxicological effects of ZnO-NPs on cardiovascular system have not been well characterized. In this study, human
Huiwen Jiang et al.
Annals of hematology, 98(7), 1721-1732 (2019-05-06)
The CD19-targeted chimeric antigen receptor T cell (CAR-T) therapy has been widely proved effective on relapsed and refractory (r/r) B cell acute lymphoblastic leukemia (B-ALL). Meanwhile, CAR-T therapy-related toxicities, including cytokine release syndrome (CRS) and neurological toxicities, are drawing researchers'
Joerg Kellermair et al.
Journal of thrombosis and thrombolysis, 50(2), 380-385 (2020-03-28)
D-Dimer has a high sensitivity but a low specificity for the diagnosis of deep vein thrombosis (DVT) which limits its implementation as a general screening parameter. There is a demand for additional biomarkers to improve its diagnostic accuracy. Soluble platelet
Andrei A Karpov et al.
International journal of molecular sciences, 22(3) (2021-01-28)
Chronic thromboembolic pulmonary hypertension (CTEPH) is a rare and life-threatening complication of pulmonary embolism. As existing animal models of CTEPH do not fully recapitulate complex disease pathophysiology, we report a new rat model for CTEPH evoked by repetitive embolization of
Claudia Strobel et al.
Beilstein journal of nanotechnology, 5, 1795-1807 (2014-11-11)
Cerium dioxide (CeO2) and silicon dioxide (SiO2) nanoparticles are of widespread use in modern life. This means that human beings are markedly exposed to them in their everyday life. Once passing biological barriers, these nanoparticles are expected to interact with

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務