跳轉至內容
Merck
全部照片(4)

重要文件

NA1020

Sigma-Aldrich

GenElute PCR 纯化试剂盒

GenElute™ PCR Clean-Up Kit

sufficient for 70 purifications

同義詞:

Gen Elute, PCR纯化

登入查看組織和合約定價


About This Item

分類程式碼代碼:
41106300
NACRES:
NA.52
暫時無法取得訂價和供貨情況

用途

sufficient for 70 purifications

品質等級

技術

DNA purification: suitable

儲存溫度

15-25°C

一般說明

GenElute PCR回收试剂盒可用于从各种其他反应组分(如多余的引物、核苷酸、DNA聚合酶、油和盐)之中快速纯化出单链或双链PCR扩增产物(长度100 bp至10 kb)。该试剂盒将硅胶结合技术的优势与传统离心柱形式结合在一起,同时无需采用昂贵的树脂或苯酚和氯仿等有毒有机化学成分。
GenElute PCR回收试剂盒可用于从各种其他反应组分(如多余的引物、核苷酸、DNA聚合酶、油和盐)之中快速纯化出单链或双链PCR扩增产物(长度100 bp至10 kb)。该试剂盒将硅胶结合技术的优势与传统离心柱形式结合在一起,同时无需采用昂贵的树脂或苯酚和氯仿等有毒有机化学成分。

DNA结合到离心柱内的硅胶膜上。结合所得的DNA经过洗涤后,再在所选的缓冲液中洗脱所得的洁净、浓缩的DNA。每个离心柱至多可纯化100 μL或10 μg经PCR扩增的DNA,至多可纯化出 95%的100 bp至10 kb大小的PCR产物。该试剂盒可去除99%以上的引物和大多数的引物二聚体(<40 bp)。

纯化所得的DNA可用于酶促反应、传统或自动化测序、克隆和微阵列分析。

應用

GenElute PCR产物纯化试剂盒已被用于从反应的其他组分中快速纯化单链或双链PCR扩增产物(100bp至10kb)。[1][2][3]
纯化所得的DNA可用于酶促反应、传统或自动化测序、克隆和微阵列分析。

特點和優勢

  • 可回收95%长度介于100 bp至10 kb之间的PCR产物
  • 可在8分钟内纯化出多达100 μL或10 μg 的PCR扩增产物DNA。
  • 可去除99%以上的引物和其他成分
  • 可在8分钟内纯化出多达100 μl或10 μg 的PCR扩增产物DNA。
  • 可回收95%长度介于100 bp至10 kb之间的PCR产物
  • 可去除99%以上的引物和其他成分
  • 不需要去除有机萃取引入的矿物油
  • 相对于其他市场领先竞争对手,可多获得40%的纯化制备物

其他說明

GenElute PCR回收试剂盒可用于从各种其他反应组分(如多余的引物、核苷酸、DNA聚合酶、油和盐)之中快速纯化出单链或双链PCR扩增产物(长度100 bp至10 kb)。该试剂盒将硅胶结合技术的优势与传统离心柱形式结合在一起,同时无需采用昂贵的树脂或苯酚和氯仿等有毒有机化学成分。

原則

GenElute PCR回收试剂盒将硅胶结合和微量离心形式的优势结合在一起。DNA结合到离心柱内的硅胶膜上。结合所得的DNA经过洗涤后,再在所选的缓冲液中洗脱所得的洁净、浓缩的DNA。每个离心柱至多可纯化100 μL或10 μg经PCR扩增的DNA,至多可纯化出 95%的100 bp至10 kb大小的PCR产物。该试剂盒可去除99%以上的引物和大多数的引物二聚体(可去除<40 bp的片段)。

法律資訊

GenElute is a trademark of Sigma-Aldrich Co. LLC

象形圖

CorrosionExclamation mark

訊號詞

Warning

危險分類

Acute Tox. 4 Oral - Eye Irrit. 2 - Met. Corr. 1 - Skin Irrit. 2 - STOT SE 3

標靶器官

Central nervous system

儲存類別代碼

8A - Combustible corrosive hazardous materials

閃點(°F)

Not applicable

閃點(°C)

Not applicable


從最近期的版本中選擇一個:

分析證明 (COA)

Lot/Batch Number

未看到正確版本?

如果您需要一個特定的版本,您可以透過批號來尋找特定憑證。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

Kathleen Gärtner et al.
Retrovirology, 6, 32-32 (2009-04-08)
Foamy viruses (FVs) are the most genetically stable viruses of the retrovirus family. This is in contrast to the in vitro error rate found for recombinant FV reverse transcriptase (RT). To investigate the accuracy of FV genome copying in vivo
Isolation of disseminated neuroblastoma cells from bone marrow aspirates for pretreatment risk assessment by array comparative genomic hybridization.
Vandewoestyne M
International Journal of Cancer. Journal International Du Cancer, 130(5), 1098-1108 (2012)
Charlotte G Cole et al.
Genome biology, 9(5), R78-R78 (2008-05-15)
Although the human genome sequence was declared complete in 2004, the sequence was interrupted by 341 gaps of which 308 lay in an estimated approximately 28 Mb of euchromatin. While these gaps constitute only approximately 1% of the sequence, knowledge
Najla Chabchoub et al.
The American journal of tropical medicine and hygiene, 80(1), 24-27 (2009-01-15)
Stool samples from 86 immunocompromised patients (51 human immunodeficiency virus (HIV)-infected patients and 35 patients with haematologic malignancies) were systematically screened for intestinal microspordiosis by microscopic examination and polymerase chain reaction (PCR) using universal primer V1/PMP2. Nine samples (10.5%) showed
Adriana P Rebelo et al.
Nucleic acids research, 37(20), 6701-6715 (2009-09-11)
To characterize the organization of mtDNA-protein complexes (known as nucleoids) in vivo, we have probed the mtDNA surface exposure using site-specific DNA methyltransferases targeted to the mitochondria. We have observed that DNA methyltransferases have different accessibility to different sites on

條款

GenElute™ PCR Clean-up Kit rapidly purifies PCR products from excess components, ensuring clean samples for downstream applications.

GenElute™ PCR Clean-up Kit 可快速純化 PCR 產品中的多餘成分,確保下游應用的樣品乾淨。

面向全基因组扩增(WGA)的SeqPlexDNA扩增试剂盒(SEQXE)专用于对极小量或降解/高度片段化的DNA进行下一代测序(NGS)。

SeqPlex DNA Amplification Kit enables NGS from small or degraded DNA quantities for whole genome amplification.

查看全部

相關內容

Whole Genome Amplification can be performed on DNA extracted in many ways. We offer many products for DNA extraction, including the GenElute™ Blood Genomic DNA Kit, GenElute Mammalian Genomic DNA Miniprep Kit and the GenElute Plant Genomic DNA M iniprep.

Questions

1–8 of 8 Questions  
  1. What is the elution buffer made of? As it can be replaced with water, is it just water that is provided?

    1 answer
    1. The specific composition of the elution buffer E7777 is considered proprietary. However it is a Tris-HCL solution without EDTA.

      Helpful?

  2. Does this kit remove proteins from PCR product?

    1 answer
    1. This is a post-pcr clean up kit. The single or double-stranded amplification products are bound to the silica membrane. Then all non-DNA material such as primers, nucleotides, and polymerase are washed away. Finally the purified product is eluted. Anything that isn't bound will be removed.

      Helpful?

  3. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?

  4. Can Product No. NA1020, GenElute™ PCR Clean-Up Kit,  be used to clean up PCR products larger than 10 kb?

    1 answer
    1. We haven't tested anything bigger than 10 kb, but we would expect larger DNA to bind well.  That said, the bound DNA might be more difficult to elute.  Heating the elution solution to 60-65°C may help with elution.  Incubating a few minutes to allow the elution solution to soak into the binding matrix may also help.

      Helpful?

  5. Can Product NA1020, GenElute™ PCR Clean-Up Kit, be used for isolation of PCR products labeled with digoxigenin?

    1 answer
    1. Although we have not tested the kit with digoxigenin-labeled PCR products specifically, it should be fine to use

      Helpful?

  6. When using Product No. NA1020, GenElute™ PCR Clean-Up Kit, what is the largest amount of PCR reaction sample that can be processed on one column?

    1 answer
    1. The upper limit on the PCR reaction volume that can be cleaned up is 100 μl. In that scenario, 500 μl of binding solution would be added for a total of 600 μl volume being applied to the column.

      Helpful?

  7. When using GenElute™ PCR Clean-Up Kit, Product No. NA1020, Can the amount of elution buffer be reduced in order to obtain a more concentrated eluate?

    1 answer
    1. One may indeed increase concentration by reducing elution volume, but we would not suggest going lower than 25-30 μl. One must keep in mind that if a volume of less than 50 μl is used (for example, 30 μl), the concentration will increase, but the total yield will also be reduced.

      Helpful?

  8. Can GenElute™ PCR Clean-Up Kit, Product NA1020, be used for isolation of labeled PCR products?

    1 answer
    1. This kit will work with labeled PCR products and no modifications to the standard protocol are needed.

      Helpful?

Reviews

Active Filters

    • Review 1
    • Vote 1
    2 out of 5 stars.

    fix the hinges or get rid of them please

    The value for money of this kit is good, but the hinges of the collection tubes are a nightmare. They dont close properly and pop open randomly with the risk of sample contamination. Please fix the hinge or get rid of them.

    Helpful?

    1. Response from MilliporeSigma:

      Thank you for your review. We are sorry to hear that your experience did not match your product expectations. We encourage customers who experience problems with our products to call or email us for additional technical support. Please visit https://www.sigmaaldrich.com/US/en/support/customer-support to submit a Product Technical Inquiry.

  1. 1 Ratings-Only Review

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務