跳轉至內容
Merck
全部照片(1)

重要文件

83263

Sigma-Aldrich

BICINE buffer Solution

BioUltra, for molecular biology, 1 M in H2O

同義詞:

N,N-Bis(2-hydroxyethyl)glycine

登入查看組織和合約定價


About This Item

經驗公式(希爾表示法):
C6H13NO4
CAS號碼:
分子量::
163.17
Beilstein:
1769362
MDL號碼:
分類程式碼代碼:
12161700
eCl@ss:
32129211
PubChem物質ID:

等級

for molecular biology

產品線

BioUltra

濃度

1 M in H2O

雜質

DNases, none detected
RNases, none detected
phosphatases, none detected
proteases, none detected

pH值

5.0±0.2

密度

1.05 g/mL at 20 °C

&lambda ;

neat

紫外吸收

λ: 260 nm Amax: <0.07
λ: 280 nm Amax: <0.04

適合性

in accordance for filter test

SMILES 字串

OCCN(CCO)CC(O)=O

儲存類別代碼

12 - Non Combustible Liquids

水污染物質分類(WGK)

WGK 3

閃點(°F)

Not applicable

閃點(°C)

Not applicable

個人防護裝備

Eyeshields, Gloves


分析證明 (COA)

輸入產品批次/批號來搜索 分析證明 (COA)。在產品’s標籤上找到批次和批號,寫有 ‘Lot’或‘Batch’.。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

S Ito et al.
Clinica chimica acta; international journal of clinical chemistry, 115(2), 135-144 (1981-09-10)
Serum guanase activity has been considered as a possible specific indicator of hepatocellular diseases. However, no suitable method is available for routine clinical determination of serum guanase activity. Conventional assay methods are troublesome and inaccurate, since guanine and 8-azaguanine, the
Yoshiteru Seo et al.
Magnetic resonance in medicine, 65(4), 1005-1012 (2011-03-18)
The toxicity of free Mn(2+) is a bottleneck for the in vivo application of manganese ion enhanced MRI. To reduce free Mn(2+) concentration ([Mn(2+) ]), a low affinity chelate reagent: N,N-bis(2-hydroxyethyl)glycine (bicine) was used. Considering the conditional association constant of
The myosin dimer: an intermediate in the self-assembly of the thick filament of vertebrate skeletal muscle.
J S Davis et al.
FEBS letters, 140(2), 293-297 (1982-04-19)
R N Roy et al.
Cryobiology, 21(6), 672-681 (1984-12-01)
The establishment of the pH (designated pH*) of a standard buffer solution suitable as a pH reference in 30, 40, and 50 mass% dimethyl sulfoxide (DMSO)/H2O mixtures at temperatures in the range -20 to 0 degrees C is reported. The
S Ito et al.
The Histochemical journal, 16(5), 489-499 (1984-05-01)
Histochemical studies of human guanase (guanine deaminase) have seldom been undertaken, in part because of technical difficulties which result in heavy background staining. In this report, we describe a modified procedure in which the methodological inadequacies have been overcome. The

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務