Sigma-Aldrich

Anti-Rabbit IgG−Abberior® STAR 488 antibody produced in goat

for STED application

同義詞:

Abberior® STAR 488-Anti-Rabbit IgG antibody produced in goat

登入查看組織和合約定價


About This Item

分類程式碼代碼:
12352200
NACRES:
NA.32

生物源

goat

品質等級

抗體表格

affinity isolated antibody

抗體產品種類

secondary antibodies

無性繁殖

polyclonal

形狀

buffered aqueous solution

物種活性

rabbit

存貨情形

available only in USA and Canada

濃度

~1 mg/mL

螢光

λex 503 nm; λem 524 nm in PBS, pH 7.4

儲存溫度

−20°C

一般說明

Abberior STAR 488 was developed for STED and confocal microscopy in the green spectral region. It is a bright green fluorescent dye. The dye works extremely well with Abberior Instruments Expert Line Microscopes and Leica STED microscopes. It can be very effectively excited with the prominent 488 nm laser line. For STED microscopy, Abberior STAR 488 can be efficiently used with STED Laser wavelengths between 590 - 610 nm. Abberior STAR 488 can substitute dyes like Oregon Green 488, Atto 488 or Alexa Fluor 488. Abberior STAR 488 is the ideal partner for Abberior STAR 440SXP to obtain optimal 2 Color STED results. Best results are obtained with freshly prepared samples.

Photophysical properties (carboxylic acid):
Absorption Maximum, λex [nm]: 503 (PBS pH 7.4), 504 (H2O), 507 (MeOH + 0.1% TFA)
Extinction Coefficient, εmax [M-1cm-1]: 65 000 (PBS pH 7.4), 80 000 (H2O), 85 000 (MeOH + 0.1% TFA)
Correction Factor, CF260 = ε260max: 0,28 (PBS pH 7.4)
Correction Factor, CF280 = ε280max: 0,14 (PBS pH 7.4)
Fluorescence Maximum, λem [nm]: 524 (PBS pH 7.4), 525 (H2O), 531 (MeOH + 0.1% TFA)
Recommended STED Wavelength, λ [nm]: 590 - 610
Fluorescence Quantum Yield, λ: 0,89 (PBS pH 7.4)
Fluorescence Lifetime, τ [ns]: 3,9 (PBS pH 7.4)

應用

Anti-Rabbit IgG-Abberior® STAR 488 antibody has been used as a secondary antibody:
  • for fluorescent immunohistochemistry in prostate cancer cell lines, PPC-1 and TSU-Pr1
  • for immunofluorescence in HeLa and monkey kidney COS-7 cells
  • for STED (stimulated emission depletion) microscopy in OLN-t40-α-syn cells (oligodendroglial cells)

適合性

Designed and tested for fluorescent super-resolution microscopy

分析報告

May contain significant amounts of BSA as stabilizer
unconjugated dye ≤5% of total fluorescence

法律資訊

ALEXA FLUOR is a trademark of Life Technologies
Atto is a trademark of Atto-Tec GmbH
abberior is a registered trademark of Abberior GmbH

未找到適合的產品?  

試用我們的產品選擇工具.

儲存類別代碼

12 - Non Combustible Liquids

水污染物質分類(WGK)

WGK 3

閃點(°F)

Not applicable

閃點(°C)

Not applicable


分析證明 (COA)

輸入產品批次/批號來搜索 分析證明 (COA)。在產品’s標籤上找到批次和批號,寫有 ‘Lot’或‘Batch’.。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

Katharina Pukaß et al.
Frontiers in cellular neuroscience, 9, 163-163 (2015-05-23)
α-Synuclein (α-syn) positive glial cytoplasmic inclusions (GCI) originating in oligodendrocytes (ODC) are a characteristic hallmark in multiple system atrophy (MSA). Their occurrence may be linked to a failure of the ubiquitin proteasome system (UPS) or the autophagic pathway. For proteasomal
Combination of axitinib and dasatinib for anti-cancer activities in two prostate cancer cell lines.
Peng N
Bangladesh Journal of Pharmacology, 11, 10-10 (2016)
Giuseppe Vicidomini et al.
Methods (San Diego, Calif.), 66(2), 124-130 (2013-07-03)
Stimulation emission depletion (STED) microscopy breaks the spatial resolution limit of conventional light microscopy while retaining its major advantages, such as working under physiological conditions. These properties make STED microscopy a perfect tool for investigating dynamic sub-cellular processes in living
T A Klar et al.
Optics letters, 24(14), 954-956 (2007-12-13)
We overcame the resolution limit of scanning far-field fluorescence microscopy by disabling the fluorescence from the outer part of the focal spot. Whereas a near-UV pulse generates a diffraction-limited distribution of excited molecules, a spatially offset pulse quenches the excited
Stefan W Hell
Nature biotechnology, 21(11), 1347-1355 (2003-11-05)
For more than a century, the resolution of focusing light microscopy has been limited by diffraction to 180 nm in the focal plane and to 500 nm along the optic axis. Recently, microscopes have been reported that provide three- to

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務