推薦產品
等級
for microscopy (Bot., Hist., Vit.)
indicator (pH 3.8-5.4)
形狀
powder
技術
titration: suitable
pH值
3.8-5.4, yellow to blue
mp
225 °C
溶解度
methanol: water (1:1): 0.1 g/10 mL, red
εmax
≥225 at 418-428 nm in methanol
應用
diagnostic assay manufacturing
hematology
histology
儲存溫度
room temp
SMILES 字串
Cc1c(Br)c(O)c(Br)cc1C2(OS(=O)(=O)c3ccccc23)c4cc(Br)c(O)c(Br)c4C
InChI
1S/C21H14Br4O5S/c1-9-12(7-14(22)19(26)17(9)24)21(13-8-15(23)20(27)18(25)10(13)2)11-5-3-4-6-16(11)31(28,29)30-21/h3-8,26-27H,1-2H3
InChI 密鑰
FRPHFZCDPYBUAU-UHFFFAOYSA-N
尋找類似的產品? 前往 產品比較指南
應用
for complexometry
儲存類別代碼
11 - Combustible Solids
水污染物質分類(WGK)
WGK 3
閃點(°F)
Not applicable
閃點(°C)
Not applicable
個人防護裝備
Eyeshields, Gloves, type N95 (US)
分析證明 (COA)
輸入產品批次/批號來搜索 分析證明 (COA)。在產品’s標籤上找到批次和批號,寫有 ‘Lot’或‘Batch’.。
客戶也查看了
Talanta, 82(3), 1027-1032 (2010-08-04)
An automatic method for kinetics independent spectrometric analysis is proposed in this study. It uses a non-linear calibration model that explores concentration gradients generated by a flow-batch analyser (FBA) for the samples, dye, and the single standard solution. The procedure
Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy, 86, 62-68 (2011-11-23)
In the present research, cadmium hydroxide nanowire loaded on activated carbon (Cd(OH)(2)-NW-AC) was synthesized and characterized. This new adsorbent was applied for the removal of Bromocresol Green (BCG) molecules from aqueous solutions. The influence of effective variables such as solution
The Journal of clinical endocrinology and metabolism, 100(7), 2613-2620 (2015-05-06)
Nutrition can affect the hypothalamus-pituitary-adrenal axis. We hypothesized that early administration of parenteral nutrition (PN) during critical illness reduces plasma ACTH and cortisol concentrations and thereby increases the use of corticosteroids. This is a preplanned substudy of a randomized controlled
Clinical journal of the American Society of Nephrology : CJASN, 10(7), 1162-1169 (2015-04-23)
Molecular evidence suggests that levels of vitamin D are associated with kidney function loss. Still, population-based studies are limited and few have considered the potential confounding effect of baseline kidney function. This study evaluated the association of serum 25-hydroxyvitamin D
Veterinary clinical pathology, 39(1), 79-82 (2009-08-26)
In reptile medicine, plasma chemistry analysis is widely used for the evaluation of an individual's health status. The standard method for the determination of plasma albumin concentration is protein electrophoresis combined with the determination of total protein concentration, but the
我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.
聯絡技術服務