跳轉至內容
Merck
全部照片(1)

文件

94131

Supelco

聚甲基丙烯酸甲酯

analytical standard, for GPC, 4,000

同義詞:

PMMA, 聚(甲基丙烯酸甲酯)

登入查看組織和合約定價


About This Item

線性公式:
[CH2C(CH3)(CO2CH3)]n
CAS號碼:
MDL號碼:
分類程式碼代碼:
41116107
PubChem物質ID:
NACRES:
NA.24

等級

analytical standard
for GPC

品質等級

自燃溫度

580 °F

儲存期限

limited shelf life, expiry date on the label

分子量

Mn ~3960
Mp ~4250
Mw ~4200
Mw/Mn ~1.06

技術

gel permeation chromatography (GPC): suitable

溶解度

H2O: insoluble

密度

1.200 g/cm3

格式

neat

儲存溫度

2-8°C

InChI

1S/C5H9O2/c1-4(2)5(6)7-3/h1-3H3

InChI 密鑰

PMAMJWJDBDSDHV-UHFFFAOYSA-N

尋找類似的產品? 前往 產品比較指南

儲存類別代碼

11 - Combustible Solids

水污染物質分類(WGK)

nwg

個人防護裝備

Eyeshields, Gloves, type N95 (US)


Choose from one of the most recent versions:

分析證明 (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

S A Bini et al.
The bone & joint journal, 95-B(3), 367-370 (2013-03-02)
We evaluated the impact of pre-coating the tibial component with polymethylmethacrylate (PMMA) on implant survival in a cohort of 16 548 primary NexGen total knee replacements (TKRs) in 14 113 patients. In 13 835 TKRs a pre-coated tray was used
Kariem Mostafa Al Batouty et al.
The journal of adhesive dentistry, 15(2), 161-166 (2013-03-28)
To compare the push-out bond strength of a new glass fiber root canal filling material to that of Resilon/ Epiphany, EndoREZ, and gutta-percha/AH Plus root canal filling materials. Sixty roots were randomly divided into four groups (n = 15) according
Bo Chen et al.
Journal of controlled release : official journal of the Controlled Release Society, 140(3), 203-209 (2009-05-26)
Water-soluble polymers for the delivery of chemotherapeutic drugs passively target solid tumors as a consequence of reduced renal clearance and the enhanced permeation and retention (EPR) effect. Elimination of the polymers in the kidney occurs due to filtration through biological
Angelo Accardo et al.
Nanoscale, 5(6), 2295-2299 (2013-02-22)
Drops of exosome dispersions from healthy epithelial colon cell line and colorectal cancer cells were dried on a superhydrophobic PMMA substrate. The residues were studied by small- and wide-angle X-ray scattering using both a synchrotron radiation micrometric beam and a
Taher Alizadeh et al.
Journal of hazardous materials, 248-249, 401-406 (2013-02-19)
It was demonstrated that a thin film of chemically exfoliated graphene flakes, blended with poly(methyl methacrylate), could be used as a chemiresistor sensor for the sensitive and selective determination of formaldehyde vapor. Formaldehyde adsorption on the sensing film led to

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務