跳轉至內容
Merck

跳轉至

IPFL07810

Immobilon®-FL PVDF Membrane

1 roll, 7 x 8.4cm, 0.45 µm pore size, Hydrophobic PVDF Transfer Membrane with low background fluorescence for Western blotting. Compatible with visible and infrared fluorescent probes.

同義詞:

Western blotting membrane, blotting membrane, transfer membrane

登入 檢視組織與合約價格。

選擇尺寸

變更視圖
給您/庫存單位供貨能力價格

關於此項目

UNSPSC Code:
41105339
eCl@ss:
32031602
NACRES:
NB.22
Material:
PVDF membrane, plain filter, white filter
Detection method:
chemiluminescent, colorimetric, fluorometric
Pore size:
0.45 μm pore size
Compatibility:
for use with Amido black, for use with CPTS, for use with Coomassie brilliant blue, for use with Ponceau-S red
暫時無法取得訂價和供貨情況
技術服務
需要援助?我們經驗豐富的科學家團隊隨時樂意為您提供支援。
讓我們為您提供幫助


產品名稱

Immobilon®-FL PVDF转移膜, 0.45 μm pore size, 7 X 8.4 cm sheets

Quality Segment

material

PVDF membrane, plain filter, white filter

feature

hydrophobic

manufacturer/tradename

Immobilon®

technique(s)

dot blot: suitable, western blot: suitable

filter L × W

7 cm × 8.4 cm

pore size

0.45 μm pore size

capacity

155 μg/cm2 adsorption capacity (insulin), 205 μg/cm2 adsorption capacity (BSA), 300 μg/cm2 adsorption capacity (goat IgG)

compatibility

for use with Amido black, for use with CPTS, for use with Coomassie brilliant blue, for use with Ponceau-S red

detection method

chemiluminescent, colorimetric, fluorometric

shipped in

ambient

General description

Immobilon®-FL转移膜是一种聚偏氟乙烯(PVDF)微孔膜,可结合从各种凝胶基质转移的蛋白质。Immobilon®-FL膜标称孔径为0.45 μm,建议用于印迹分子量大于20千道尔顿(kDa)的蛋白质。这种膜在很宽的激发/发射波长范围内显示非常低的自荧光。这种特性使其成为包括荧光免疫检测在内的印迹应用的理想材料。
过滤器代码:IPFL

Application

Immobilon®-FL转移膜已用于蛋白质印迹分析。

Features and Benefits

Immobilon®-FL转移膜:
  • 专为最佳荧光免疫检测应用而设计
  • 极低的背景提高了所有荧光检测协议的灵敏度
  • 在广泛的激发/发射波长范围内兼容所有常用的荧光探针
  • 可用于标准化学发光或显色检测

Legal Information

Immobilon is a registered trademark of Merck KGaA, Darmstadt, Germany

比較類似項目

查看完整比較

Show Differences

1 of 1

本產品
IPFL10100IPFL00010IPFL20200
description

0.45 μm pore size, 7 X 8.4 cm sheets

description

10 sheets, 10 cm x 10 cm, 0.45 µm pore size, Hydrophobic PVDF Transfer Membrane with low background fluorescence for Western blotting. Compatible with visible and infrared fluorescent probes.

description

1 roll, 27 cm x 3.75 m, 0.45 µm pore size, Hydrophobic PVDF Transfer Membrane with low background fluorescence for Western blotting. Compatible with visible and infrared fluorescent probes.

description

10 sheets, 20 cm x 20 cm, 0.45 µm pore size, Hydrophobic PVDF Transfer Membrane with low background fluorescence for Western blotting. Compatible with visible and infrared fluorescent probes.

Quality Level

400

Quality Level

400

Quality Level

400

Quality Level

400

pore size

0.45 μm pore size

pore size

0.45 μm pore size

pore size

0.45 μm pore size

pore size

0.45 μm pore size

material

PVDF membrane, white filter, plain filter

material

PVDF membrane, plain filter, white filter

material

PVDF membrane, plain filter, white filter

material

PVDF membrane, plain filter, white filter

compatibility

for use with Amido black, for use with Coomassie brilliant blue, for use with CPTS, for use with Ponceau-S red

compatibility

for use with Amido black, for use with CPTS, for use with Coomassie brilliant blue, for use with Ponceau-S red

compatibility

for use with All fluorescence dyes, for use with Amido black, for use with CPTS, for use with Coomassie brilliant blue, for use with Ponceau-S red, for use with Sypro<TMSYMBOL></TMSYMBOL> ruby

compatibility

for use with Amido black, for use with CPTS, for use with Coomassie brilliant blue, for use with Ponceau-S red

detection method

chemiluminescent, fluorometric, colorimetric

detection method

chemiluminescent, colorimetric, fluorometric

detection method

chemiluminescent, colorimetric, fluorometric

detection method

chemiluminescent, colorimetric, fluorometric

manufacturer/tradename

Immobilon®

manufacturer/tradename

Immobilon®

manufacturer/tradename

Immobilon®

manufacturer/tradename

Immobilon®


Still not finding the right product?

Explore all of our products under Immobilon®-FL PVDF转移膜


存儲類別/等級

11 - Combustible Solids

wgk

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable



從最近期的版本中選擇一個:

分析證明 (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 文件 section.

如果您需要協助,請聯絡 客戶支援

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫



Questions

  1. Could you confirm if the IPFL07810 Immobilon membrane is compatible with a specific imaging system? I need to verify if this product will work for my requirements.

    1 answer
    1. Yes, low-fluorescent PVDF membrane is required in Licor IR Imaging Systems. The Immobilon-FL PVDF Membrane is suitable for this purpose. Immobilon-FL Membrane is the first transfer membrane optimized for fluorescence applications, with extremely low background that improves the sensitivity of all fluorescence detection protocols. It is compatible with all commonly used fluorescent probes at all excitation and emission wavelengths, making it ideal for multiplexing and chemifluorescence applications.

      Helpful?

Reviews

No rating value

Active Filters