跳轉至內容
Merck
全部照片(1)

文件

CWL971S03

Millipore

Milligard® LPB 1.2 µm, Cartridge

pore size 1.2 μm, cartridge nominal length 10 in. (25 cm)

同義詞:

Milligard Low Protein Binding Cartridge Filter 10 in. Code 7 1.2 μm

登入查看組織和合約定價


About This Item

分類程式碼代碼:
23151806
eCl@ss:
32031610

材料

mixed cellulose esters (MCE) (low protein-binding)
polyester support
polypropylene
silicone seal

品質等級

無菌

non-sterile

滅菌相容性

autoclavable compatible
steam-in-place compatible

產品線

Milligard®

特點

hydrophilic

製造商/商標名

Milligard®

參數

3.5 bar max. differential pressure (50 psid) at 25 °C
3.5 bar max. inlet pressure (50 psi) at 25 °C

技術

prefiltration: suitable

長度

10 in.

寬度

2.9 in.

柱標稱長度

10 in. (25 cm)

直徑

7.1 cm (2.8 in.)

過濾面積

0.8 m2

雜質

≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

重量法萃取物

≤250 mg/cartridge

基質

Milligard® LPB

孔徑

1.2 μm nominal pore size
1.2 μm pore size

輸入

sample type liquid

柱代碼

Code 7

尋找類似的產品? 前往 產品比較指南

一般說明

Device Configuration: Cartridge

特點和優勢

Format: Single Layer

包裝

Double Easy-Open bag

其他說明

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Directions for Use:
  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer to the installation and wetting sections of OptiScale®-25 user guide and introduction section of the Mixed cellulose esters Tech Brief
  • Storage Statement: Please refer to the Mixed cellulose esters Tech Brief
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

規格

Filter Grade: Low Protein Binding Milligard® Media

準備報告

Sterilization Method
10 autoclave cycles or SIP @ 121 °C for 30 min
This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

分析報告

Gravimetric Extractables: after a 5 L flush and 24 hours in water at controlled room temperature
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥9 L

法律資訊

MILLIGARD is a registered trademark of Merck KGaA, Darmstadt, Germany
OptiScale is a registered trademark of Merck KGaA, Darmstadt, Germany

未找到適合的產品?  

試用我們的產品選擇工具.

象形圖

Flame

訊號詞

Danger

危險聲明

危險分類

Flam. Sol. 1

儲存類別代碼

4.1B - Flammable solid hazardous materials

水污染物質分類(WGK)

WGK 2


分析證明 (COA)

輸入產品批次/批號來搜索 分析證明 (COA)。在產品’s標籤上找到批次和批號,寫有 ‘Lot’或‘Batch’.。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務