1.00595

Supelco

Chlorine Test, photometric

photometric, 0.010-6.00 mg/L (Cl2), Spectroquant®

登入查看組織和合約定價


About This Item

分類程式碼代碼:
41116116
NACRES:
NA.24

product name

Chlorine Cell Test, photometric, 0.010-6.00 mg/L (Cl2), Spectroquant®

產品線

Spectroquant®

品質等級

用途

sufficient for 200 tests (free chlorine)

特定分析物

chlorine

測量範圍

0.010-6.00 mg/L (Cl2)

技術

photometry: suitable

相容性

for use with Spectroquant® Move 100
for use with Spectroquant® Nova 60 A
for use with Spectroquant® Prove 100
for use with Spectroquant® Prove 300
for use with Spectroquant® Prove 600

檢測方法

photometric (DPD)

儲存溫度

15-25°C

一般說明

(free chlorine) Method: photometric, DPD 0.03 - 6.00 mg/l Cl₂ Spectroquant®
This Spectroquant® Chlorine test allows the accurate quantification of chlorine in various waters. Chlorinated disinfectants are still in common use all over the world, their major applications being in the chlorination of drinking water and swimming pools. In weakly acidic solution free chlorine reacts with dipropyl-p-phenylenediamine (DPD) to form a red-violet dye that is determined photometrically.
The method is analogous to EPA 330.5, APHA 4500-Cl2 G, and DIN EN ISO 7393-2.
All our Cell and Reagent Test Kits are equipped with the unique Live ID (2D barcode) which allows seamless method recognition and contains essential information such as lot number, expiry date, and automatic calibration updates.
The Spectroquant® Cell Tests come with prefilled 16 mm round cells as well as all the required reagents to perform the analysis according to the procedure described in the accompanying instruction leaflet.

應用


  • Sustainable lindane waste remediation: Surfactant-driven residual DNAPL extraction and oxidation in a real landfill (LIFE SURFING).: This study uses a chlorine cell test to assess the effectiveness of surfactant-driven extraction and oxidation processes for the remediation of lindane waste in a landfill, highlighting innovative environmental cleanup methods (Fernández et al., 2024).

  • Disinfectant-induced ammonia oxidation disruption in microbial N-cycling process in aquatic ecosystem after the COVID-19 outbreak.: Utilizes chlorine cell tests to study the impact of disinfectants on microbial nitrogen cycling in aquatic systems, providing critical insights into environmental effects of increased disinfectant use during the pandemic (Yang et al., 2024).


法律資訊

SPECTROQUANT is a registered trademark of Merck KGaA, Darmstadt, Germany

象形圖

Exclamation markHealth hazard

訊號詞

Danger

危險聲明

危險分類

Eye Irrit. 2 - Repr. 1B

儲存類別代碼

6.1D - Non-combustible, acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects

水污染物質分類(WGK)

WGK 2

閃點(°F)

Not applicable

閃點(°C)

Not applicable


分析證明 (COA)

輸入產品批次/批號來搜索 分析證明 (COA)。在產品’s標籤上找到批次和批號,寫有 ‘Lot’或‘Batch’.。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

客戶也查看了

Slide 1 of 1

1 of 1

條款

AQA Standard for free chlorine - Preparation of a standard solution for free chlorine

AQA 游离氯标准品 - 游离氯标准溶液的制备

Preparation of a standard solution for free Chlorine according to DIN EN ISO 7393

游离氯标准溶液的制备,符合 DIN EN ISO 7393

查看全部

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務