跳轉至內容
Merck
全部照片(1)

Key Documents

P-055

Supelco

普萘洛尔 盐酸盐 溶液

1.0 mg/mL in methanol (as free base), ampule of 1 mL, certified reference material, Cerilliant®

登入查看組織和合約定價


About This Item

經驗公式(希爾表示法):
C16H21NO2·HCl
CAS號碼:
分子量::
295.80
EC號碼:
分類程式碼代碼:
41116107
NACRES:
NA.24

等級

certified reference material

品質等級

形狀

liquid

特點

Snap-N-Spike®/Snap-N-Shoot®

包裝

ampule of 1 mL

製造商/商標名

Cerilliant®

濃度

1.0 mg/mL in methanol (as free base)

技術

gas chromatography (GC): suitable
liquid chromatography (LC): suitable

應用

clinical testing

格式

single component solution

儲存溫度

−20°C

SMILES 字串

Cl.CC(C)NCC(O)COc1cccc2ccccc12

InChI

1S/C16H21NO2.ClH/c1-12(2)17-10-14(18)11-19-16-9-5-7-13-6-3-4-8-15(13)16;/h3-9,12,14,17-18H,10-11H2,1-2H3;1H

InChI 密鑰

ZMRUPTIKESYGQW-UHFFFAOYSA-N

基因資訊

一般說明

一种经认证的参比溶液,适用于临床和诊断测试、尿液药物测试、法医分析或临床毒理学的LC/MS或GC/MS测试方法的校准器和控制的起始材料。普萘洛尔是一种交感神经非选择性受体阻滞剂,用于治疗高血压、焦虑和恐慌等多种疾病。该药物以Inderal®、Avlocardyl、Deralin和Dociton等许多商品名出售。

應用

<ul>
<li><strong>Propranolol hydrochloride solution for infantile hemangioma:</strong>Liposomal formulations of propranolol hydrochloride have been developed for the treatment of infantile hemangioma, offering a targeted therapeutic approach in pediatric dermatology (Nifli et al., 2024).</li>
<li><strong>Propranolol hydrochloride:</strong> Research on the percutaneous absorption of solvent-deposited propranolol hydrochloride across different skin layers provides insights into its properties like it can be used as a function of dose and ionization state and as a calibration standard (Tonnis et al., 2024).</li>
</ul>

法律資訊

CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany
Inderal is a registered trademark of Cranford Pharmaceuticals, LLC
Snap-N-Shoot is a registered trademark of Cerilliant Corporation
Snap-N-Spike is a registered trademark of Merck KGaA, Darmstadt, Germany

訊號詞

Danger

危險分類

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1

標靶器官

Eyes

儲存類別代碼

3 - Flammable liquids

水污染物質分類(WGK)

WGK 1

閃點(°F)

49.5 °F - closed cup

閃點(°C)

9.7 °C - closed cup


分析證明 (COA)

輸入產品批次/批號來搜索 分析證明 (COA)。在產品’s標籤上找到批次和批號,寫有 ‘Lot’或‘Batch’.。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

What doesn't kill may not make you stronger. β-blockers for asthma.
Shamsah Kazani et al.
American journal of respiratory and critical care medicine, 187(12), 1281-1281 (2013-06-19)
Philip M Short et al.
American journal of respiratory and critical care medicine, 187(12), 1308-1314 (2013-04-19)
Unblinded studies have shown improvements in airway hyperresponsiveness with chronic nadolol in steroid-naive patients with asthma. To assess the effects of chronic nonselective β-blockade as add-on to inhaled corticosteroids (ICS) in patients with asthma. A double-blind randomized placebo-controlled crossover trial
Jun Zhang et al.
Rapid communications in mass spectrometry : RCM, 27(7), 731-737 (2013-03-16)
Multiplexed liquid chromatography (LC) coupled with multiple-injection-chromatogram acquisition has emerged as the method of choice for high-speed discovery bioanalysis, because it significantly reduces injection-to-injection cycle time while maintaining the chromatography quality. Historically, systems utilizing this approach had been custom built
[Propanolol effective treatment for laryngo-tracheal hemangioma].
Markus Granholm et al.
Lakartidningen, 110(19-20), 947-948 (2013-06-12)
Bojko Bjelakovic et al.
Drug design, development and therapy, 7, 127-129 (2013-03-08)
We hypothesized that some characteristics of beta-blockers, including negative inotropic, peripheral vasoconstrictor, and antiangiogenic effects, might be potentially useful in treating children with epistaxis. From June 2010 to March 2012, a total of seven children with recurrent primary epistaxis resistant

文章

This article highlights the impact that sample matrix effects can have on LC/MS response and discusses two novel approaches to reduce it.

Learn about Supel™ BioSPME C18 high-throughput devices to determine plasma protein binding and decrease the sample preparation time to less than an hour.

Comparative analysis of Supel™ BioSPME 96-Pin device with a rapid equilibrium dialysis technique for accuracy of measured values, sample cleanliness, and workflow time in drug protein binding.

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務