跳轉至內容
Merck
全部照片(2)

Key Documents

GF71975065

foil, 10mm disks, thickness 0.05mm, as rolled, 99.95+%

同義詞:

登入查看組織和合約定價


About This Item

線性公式:
Ag
CAS號碼:
分子量::
107.87
MDL號碼:
分類程式碼代碼:
12141740
PubChem物質ID:
NACRES:
NA.23

化驗

99.95%

形狀

foil

製造商/商標名

Goodfellow 719-750-65

電阻係數

1.59 μΩ-cm, 20°C

直徑× 厚度

10 mm × 0.05 mm

bp

2212 °C (lit.)

mp

960 °C (lit.)

密度

10.49 g/cm3 (lit.)

SMILES 字串

[Ag]

InChI

1S/Ag

InChI 密鑰

BQCADISMDOOEFD-UHFFFAOYSA-N

相關類別

一般說明

For updated SDS information please visit www.goodfellow.com.

法律資訊

Product of Goodfellow

儲存類別代碼

13 - Non Combustible Solids

水污染物質分類(WGK)

WGK 3

閃點(°F)

Not applicable

閃點(°C)

Not applicable


分析證明 (COA)

輸入產品批次/批號來搜索 分析證明 (COA)。在產品’s標籤上找到批次和批號,寫有 ‘Lot’或‘Batch’.。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

Ken-ichiro Matsumoto et al.
Biological & pharmaceutical bulletin, 28(11), 2029-2034 (2005-11-08)
A novel screening experiment, to find radioactive probes for non-invasive measurements of physiological functions in experimental animals, was tested using the in vivo multitracer analysis technique. The details of the efficiency of the detector settings used in the in vivo
Fan Yang et al.
Talanta, 84(4), 1099-1106 (2011-05-03)
In this paper, a compact and inexpensive light emitting diode induced fluorescence (LED-IF) detector with simplified optical configuration was developed and assembled in an integrated microfluidic device for microscale electrophoresis. The facile detector mainly consisted of an LED, a focusing
H H Wiebe et al.
Plant physiology, 59(2), 256-258 (1977-02-01)
Water potential was monitored at nine locations along single maize (Zea mays L.) leaf blades with aluminum block in situ thermocouple hygrometers. Water potential showed a continuous decrease toward the tip, with a 2- to 4-bar difference between leaf base
A Rupérez et al.
Talanta, 44(2), 213-220 (1997-02-01)
Surface-enhanced Raman scattering (SERS) spectrometry of the diuretic drug triamterene is discussed. The SERS-active substrate used is a silver foil etched with nitric acid. The influence of solvent and sample doping method on sensivity, intercept and shape of the calibration
M Dubiel et al.
Journal of synchrotron radiation, 8(Pt 2), 539-541 (2001-08-22)
The thermal expansion behaviour of silver fcc has been described by an anharmonic Einstein model using EXAFS data in the temperature range between 10 and 300 K. The linear expansion coefficient of a bulk silver foil agrees well with X-ray

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務