跳轉至內容
Merck
全部照片(1)

文件

295361

Sigma-Aldrich

六氟乙烷

≥98%

同義詞:

CFC-116, 全氟乙烷

登入查看組織和合約定價


About This Item

線性公式:
CF3CF3
CAS號碼:
分子量::
138.01
EC號碼:
MDL號碼:
分類程式碼代碼:
12142100
PubChem物質ID:
NACRES:
NA.22

蒸汽密度

4.7 (vs air)

蒸汽壓力

430 psi ( 21 °C)

化驗

≥98%

bp

−78 °C (lit.)

mp

−100 °C (lit.)

SMILES 字串

FC(F)(F)C(F)(F)F

InChI

1S/C2F6/c3-1(4,5)2(6,7)8

InChI 密鑰

WMIYKQLTONQJES-UHFFFAOYSA-N

包裝

Supplied in a carbon steel lecture bottle with a CGA180M/CGA110F needle valve installed.

Compatible with the following:
  • Aldrich® lecture-bottle station systems
  • Aldrich® lecture-bottle gas regulators

其他說明

法律資訊

Aldrich is a registered trademark of Sigma-Aldrich Co. LLC

排氣閥

產品號碼
描述
訂價

軟管倒鉤

產品號碼
描述
訂價

象形圖

Gas cylinder

訊號詞

Warning

危險聲明

防範說明

危險分類

Press. Gas Liquefied gas

儲存類別代碼

2A - Gases

水污染物質分類(WGK)

WGK 3

閃點(°F)

Not applicable

閃點(°C)

Not applicable

個人防護裝備

Eyeshields, Gloves, multi-purpose combination respirator cartridge (US)


分析證明 (COA)

輸入產品批次/批號來搜索 分析證明 (COA)。在產品’s標籤上找到批次和批號,寫有 ‘Lot’或‘Batch’.。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

Harvey Lincoff et al.
Retina (Philadelphia, Pa.), 28(1), 56-59 (2008-01-11)
To test the validity of the geometric conclusion that 40 degrees gaze down is optimal for pneumatic displacement of a subretinal hemorrhage (SRH) in the macula. Nine consecutive patients with SRH in the macula had an intravitreal injection of perfluorocarbon
Luiz Fernando Lepre et al.
Physical chemistry chemical physics : PCCP, 21(17), 8865-8873 (2019-04-13)
After studying the properties of a mixture of hydrogenated and fluorinated ionic liquids we have measured the solubility of perfluoromethane, perfluoroethane and perfluoropropane in 1-alkyl-3-methylimidazolium based ionic liquids with hydrogenated or fluorinated alkyl side-chains: 1-octyl-3-methylimidazolium bis[trifluoromethylsulfonyl]amide ([C8C1Im][NTf2]), 1-octyl-3-methylimidazolium bis[pentafluoroethylsulfonyl]amide ([C8C1Im][BETI])
Rubina Rahman et al.
The British journal of ophthalmology, 96(2), 185-188 (2011-05-19)
To compare the outcomes of non-posturing macular-hole surgery using sulfur hexafluoride (SF(6)) gas versus perfluoroethane (C(2)F(6)) for idiopathic macular hole repair. Design Interventional, comparative cohort study. 39 eyes of 38 patients undergoing macular-hole surgery with SF(6) were compared with another
[Long-lasting expanding gases for the treatment of vitreo-retinal diseases].
Akito Hirakata
Nippon Ganka Gakkai zasshi, 112(1), 3-6 (2008-02-05)
Aurore Muselier et al.
American journal of ophthalmology, 150(3), 387-391 (2010-07-10)
To compare the functional and the anatomic outcomes of a combined surgery and consecutive surgery for macular hole and cataract extraction. Multicenter, retrospective, comparative case series. One hundred twenty patients (120 eyes) with an idiopathic macular hole and cataract were

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務