跳轉至內容
Merck
全部照片(3)

文件

114480

Sigma-Aldrich

甲酚红 钠盐

indicator grade

登入查看組織和合約定價


About This Item

經驗公式(希爾表示法):
C21H17NaO5S
CAS號碼:
分子量::
404.41
EC號碼:
MDL號碼:
分類程式碼代碼:
12171500
PubChem物質ID:
NACRES:
NA.47

等級

indicator grade

形狀

solid

mp

250 °C (dec.) (lit.)

溶解度

H2O: 1 mg/mL

λmax

425 nm

應用

diagnostic assay manufacturing
hematology
histology

儲存溫度

room temp

SMILES 字串

[Na+].Cc1cc(ccc1O)\C(=C2/C=CC(=O)C(C)=C2)c3ccccc3S([O-])(=O)=O

InChI

1S/C21H18O5S.Na/c1-13-11-15(7-9-18(13)22)21(16-8-10-19(23)14(2)12-16)17-5-3-4-6-20(17)27(24,25)26;/h3-12,22H,1-2H3,(H,24,25,26);/q;+1/p-1/b21-16-;

InChI 密鑰

GBXGEGUVARLBPB-PLMZOXRSSA-M

尋找類似的產品? 前往 產品比較指南

應用

甲酚红已被用于检查固定的碳酸酐酶催化的反应。它也被用于通过PCR进行I类MHC(主要组织相容性复合体)分型的上样缓冲液中。

生化/生理作用

甲酚红可用作pH指示剂。

儲存類別代碼

11 - Combustible Solids

水污染物質分類(WGK)

WGK 3

閃點(°F)

Not applicable

閃點(°C)

Not applicable

個人防護裝備

Eyeshields, Gloves, type N95 (US)


分析證明 (COA)

輸入產品批次/批號來搜索 分析證明 (COA)。在產品’s標籤上找到批次和批號,寫有 ‘Lot’或‘Batch’.。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

K Horie et al.
Analytical biochemistry, 137(1), 80-87 (1984-02-01)
A highly sensitive quantitative method was developed to detect protons released or taken up upon ligand binding. A small change in pH due to proton release or uptake was detected by measuring the difference in the absorbance of a pH
E Hodges et al.
Molecular pathology : MP, 50(3), 164-166 (1997-06-01)
Diagnostic immunoglobulin (Ig) polymerase chain reaction (PCR) clonality analyses need to be simple, reproducible, and rapid. Sucrose and cresol red (gel loading buffer reagents) were added to a routine IgH PCR reaction mix to obviate the need for adding gel
Paula C A Jerónimo et al.
The Analyst, 130(8), 1190-1197 (2005-07-16)
An optical biosensor based on immobilised carbonic anhydrase and its application to the determination of the anti-glaucoma agent acetazolamide by enzyme inhibition measurements, is described. The enzyme and a pH indicator dye, cresol red, were physically immobilised in overlapped sol-gel
[Fundamental studies on the measurement of urinary NAG and determination of the normal values for NAG activity in various age groups].
Y Iimura et al.
Rinsho byori. The Japanese journal of clinical pathology, 31(2), 179-184 (1983-02-01)
K Schilling et al.
Clinical chemistry, 39(2), 251-256 (1993-02-01)
If buffer/indicator systems are used as optical thermometers in multicuvettes, the temperature resolution is limited by errors of optical measurements produced mainly by variations of pathlength and blank transmittance of the wells. Theoretical and practical approaches show that, in multicuvettes

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務