12390-U

Supelco

金属填充GC色谱柱(常规配置)

phase none, matrix 60/80 Carboxen-1000 support, L × O.D. × I.D. 15.0 ft (4.6 m) × 1/8 in. × 2.1 mm

别名:

carboxen 1000 GC色谱柱

登录查看公司和协议定价

选择尺寸

1 EA
$723.00

$723.00


请联系客服了解存货情况


选择尺寸

变更视图
1 EA
$723.00

About This Item

UNSPSC代码:
41115710
NACRES:
SB.54

$723.00


请联系客服了解存货情况

物料

stainless steel column

质量水平

参数

0-225 °C temperature (isothermal or programmed)

技术

gas chromatography (GC): suitable

长度 × 外径 × 内径

15.0 ft (4.6 m) × 1/8 in. × 2.1 mm

基质

60/80 Carboxen-1000 support

基质活性基团

none phase

色谱柱类型

packed GC

相容性

for use with General Configuration

正在寻找类似产品? 访问 产品对比指南

一般描述

对于不需要玻璃惰性的低要求应用,应使用经济型的金属柱。该色谱柱具有一般性配置,并可小心将其弯曲以适用于大多数仪器。
当采用较高的载气流速时,基本上使用的是由不锈钢而制成的填充柱,因为它们可以承受更高的压力。不锈钢柱通常先用稀盐酸洗涤,然后用水及随后的甲醇、丙酮、二氯甲烷和正己烷洗涤,以除去任何腐蚀产物和痕量的润滑剂。[1]

应用

填充在不锈钢柱中的Carboxen 1000可在厌氧室中用于产甲烷古菌的研究。[2]

储存分类代码

11 - Combustible Solids

WGK

nwg

闪点(°F)

Not applicable

闪点(°C)

Not applicable


历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 文件 section.

如需帮助,请联系 客户支持

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Matthew J Higgins et al.
Water research, 122, 557-569 (2017-06-20)
A study was performed to evaluate the effect of thermal hydrolysis pretreatment (THP) temperature on subsequent digestion performance and operation, as well as downstream parameters such as dewatering and cake quality. A blend of primary and secondary solids from the
Michael J McAnulty et al.
Biotechnology and bioengineering, 114(4), 852-861 (2016-11-02)
We previously demonstrated anaerobic conversion of the greenhouse gas methane into acetate using an engineered archaeon that produces methyl-coenzyme M reductase (Mcr) from unculturable microorganisms from a microbial mat in the Black Sea to create the first culturable prokaryote that
Archaea: A Laboratory Manual: Methanogens.
Robb FT, et al.
Science, 28-30 (1994)
Introduction to Analytical Gas Chromatography.
Scott RPW.
Science, 102-108 (1997)

Questions

  1. Could you elaborate on the process of bending the column to accommodate different instruments for the product Metal Packed GC Column (General Configuration), SKU 12390-U?

    1 answer
    1. Stainless steel 1/8" GC columns can be adjusted to fit a particular instrument, provided that the tubing is not kinked or bent excessively. If reshaping is necessary, it should be done slowly and carefully, especially for columns packed with carbon-based material, like Carboxen-1000, or any column containing carbon-based material that may fracture if the tubing is bent too far. Fractured packing, regardless of type, can lead to active sites that may adsorb specific types of compounds.

      Helpful?