跳转至内容
Merck

MAK310

Sigma-Aldrich

氨检测试剂盒

Ammonia Assay Kit

sufficient for 200 fluorometric tests

别名:

氨定量检测试剂盒

登录查看公司和协议定价

选择尺寸

1 KIT
$300.00

$300.00


预计发货时间2025年4月14日详情


获取大包装报价

选择尺寸

变更视图
1 KIT
$300.00

About This Item

UNSPSC代码:
12161503
NACRES:
NA.84

$300.00


预计发货时间2025年4月14日详情


获取大包装报价

检测方法

fluorometric

相关疾病

genitourinary disorders; gastrointestinal diseases

储存温度

−20°C

一般描述

氨 (NH 3 ) 或铵离子 (NH 4 + ) 存在于大气、雨水、土壤、海水和火山地区。它被广泛用作肥料,是生命系统的重要氮源。它在动物生理中也起着一定的作用。氨由氨基酸代谢产生,在人体肝脏通过尿素循环转化为尿素。氨作为各种其他氮化合物的前体。为无色气体,有刺激性气味,极易液化。在畜牧业中也用作饲料添加剂。[1]

特点和优势

兼容高通量操作系统。

适用性

适用于定量测定生物样品(如尿液和环境样品)中氨/铵浓度。

原理

氨气测定试剂盒提供了一种简单且高通量的适应性测定法,用于定量测定生物样品(如尿液和环境样品)中氨/铵离子的浓度。 该测定基于苯二甲醛法,其中试剂与氨/铵离子反应产生荧光测定结果(ex = 360 / em = 450nm),与样品中的氨浓度成正比。 该试剂盒的96孔格式线性检测范围为0.012-1mM氨水。

警示用语:

Danger

危险分类

Acute Tox. 4 Oral - Aquatic Acute 1 - Aquatic Chronic 1 - Eye Dam. 1 - Skin Corr. 1B - Skin Sens. 1

储存分类代码

8A - Combustible corrosive hazardous materials

闪点(°F)

188.6 °F

闪点(°C)

87 °C


历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Beatriz Vallejo et al.
Microbial cell factories, 19(1), 124-124 (2020-06-09)
Saccharomyces cerevisiae wine strains can develop stuck or sluggish fermentations when nutrients are scarce or suboptimal. Nutrient sensing and signaling pathways, such as PKA, TORC1 and Snf1, work coordinately to adapt growth and metabolism to the amount and balance of
Umarah Mubeen et al.
The Plant cell, 30(10), 2240-2254 (2018-09-20)
The Target of Rapamycin (TOR) kinase is a central regulator of growth and metabolism in all eukaryotic organisms, including animals, fungi, and plants. Even though the inputs and outputs of TOR signaling are well characterized for animals and fungi, our
Daphné Coache et al.
PloS one, 17(6), e0270206-e0270206 (2022-06-25)
This study assessed the stability of six extemporaneously compounded hydroxyurea oral liquids stored at room temperature. Hydroxyurea oral liquids (100 mg/mL) were prepared using three different mixing methods (mortar, mixer or QuartetRx) from either bulk powder, capsule content, or whole
Hazardous materials chemistry for emergency responders, 553-553 (2013)
Zilin Li et al.
Nature, 599(7884), 290-295 (2021-10-22)
Mouse caspase-11 and human caspase-4 and caspase-5 recognize cytosolic lipopolysaccharide (LPS) to induce pyroptosis by cleaving the pore-forming protein GSDMD1-5. This non-canonical inflammasome defends against Gram-negative bacteria6,7. Shigella flexneri, which causes bacillary dysentery, lives freely within the host cytosol where these caspases

Questions

1–9 of 9 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  3. What is the composition of reagent A and reagent B supplied with the MAK310 assay kit?

    1 answer
    1. The exact percentages as exact reagent composition are proprietary. The composition can be provided in ranges as follows; Reagent A: Contains 1-15% o-phthalaldehyde, CAS #: 643-79-8, and 10-99% dimethyl sulfoxide, CAS#: 67-68-5. Reagent B: Contains 0.1-5% β-Mercaptoethanol, CAS#: 60-24-2, and 10-99% dimethyl sulfoxide, CAS#: 67-68-5.

      Helpful?

  4. Can i use this assay kit to determine the ammonia amount of culture media sample? (RPMI-1640)

    1 answer
    1. This kit has not been tested for use with cell culture samples or supernatants, including those containing RPMI-1640. Amine-containing buffers such as Tris buffers should be avoided. In addition, high protein concentrations may interfere with the reaction. The end user would have to determine suitability. Product MAK538, Ammonia Assay Kit, would be a more suitable product for use in cell culture applications. Please see the link below to review this product option:
      https://www.sigmaaldrich.com/product/sigma/mak538

      Helpful?

  5. What is the recommended protocol for the storage and freeze/thaw of the ammonia assay kit (MAK310)? Is it permissible to aliquot portions in advance, or is the kit stable for a certain period of time at 4°C? Furthermore, what is the optimal method for thawing the kit (on ice)? Additionally, what is the shelf life of the reagents once thawed? Should the thawed "working" reagents be stored at 4°C or room temperature until they are used (within the timeframe of the above question)?

    1 answer
    1. It is advisable to aliquot portions of the reagents in advance to minimize the number of freeze-thaw cycles. Thawing the components at room temperature is acceptable. But, there is no specific data available regarding the stability of the reagents once they are thawed. It is recommended to prepare smaller aliquots of the reagents, enough for the number of assays the customer intends to run, to avoid having an excessive amount of reagent after an experiment. While it is acceptable to refreeze the leftover aliquots for future use, it is advisable to minimize multiple freeze-thaw cycles. The reagents may be temporarily stored at 4°C if necessary during an experiment. Additionally, it is recommended to create a standard curve according to the protocol, and if the curve is linear, then the kit should be functioning properly.

      Helpful?

  6. Can this kit chemistry be used directly with serum samples, or will the protein content interfere with the assay?

    1 answer
    1. The kit chemistry cannot be used directly with serum samples. Deproteinization is necessary before running the assay, and this can be achieved by passing the sample through 10 kDa cutoff filters. Alternatively, proteins can be chemically precipitated using TCA, although this method has not been tested with this kit. If using acid for protein separation, it is important to neutralize the sample with a base before running the assay.

      Helpful?

  7. To calculate the molarity of my samples, do I need to multiply it by the dilution factor of the final reaction volume? According to technical bulletin, standards are diluted 1/10 at final molarity of .1 mM at the highest point of the curve.

    1 answer
    1. If 10 uL of undiluted sample is used before adding the 90 uL of working reagent, then no dilution factor is needed. The dilution factor is only needed if the sample has been diluted before the pipetting for 10 uL into the sample well. For example, if the kit is used and the ammonia concentration is 1 mM or greater, it is necessary to dilute the sample in water and repeat the assay. Multiply the results by the dilution factor. If the sample is diluted 10-fold, then a dilution factor of '10' would need to be applied to the results.

      Helpful?

  8. Is this a stand alone test or does it require external instrumentation?

    1 answer
    1. A 96 well plate is not included in this kit. A plate reader is also required. Please see the 'Reagents and Equipment Required but Not Provided with this kit' on the Product Information Sheet:
      https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/196/522/mak310bul.pdf

      Helpful?

  9. Is this kit suitable for seawater samples?

    1 answer
    1. Yes, the Ammonia Assay Kit provides a simple and high throughput adaptable assay for quantitative determination of ammonia/ammonium ion concentration in biological samples, such as urine, and environmental samples.

      Helpful?

Reviews

Active Filters

    • Review 1
    • Votes 0
    2 out of 5 stars.

    Limited uses

    I would not recommend using this kit for any kind of sample that contains free amino acids as o-phthalaldehyde will readily bind and contribute to fluorescence. I tested for a few different types of cell culture media (including protein depleted samples) and also buffer samples containing only glutamate and alanine and all gave dose dependent levels of interference, making the kit very non-specific. However, for ammonia only samples in simple and appropriate buffers, it worked fine.

    Helpful?

    1. Response from MilliporeSigma:

      This assay is based on the o-phthalaldehyde method in which the reagent reacts with ammonia/ammonium ion producing a fluorometric result ( ex = 360/ em = 450nm), proportional to the ammonia concentration in the sample. It will not differentiate between ammonia, free amino acids, or other components that react with o-phthalaldehyde. The end user would need to determine suitability with their samples.

      We encourage customers who experience problems with our products to contact us for additional technical support. Please visit https://www.sigmaaldrich.com/US/en/support/customer-support to submit a Product Technical Inquiry.

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系客户支持