推荐产品
蒸汽密度
3.6 (vs air)
品質等級
蒸汽壓力
12.4 mmHg ( 37.7 °C)
4.3 mmHg ( 15 °C)
產品線
ReagentPlus®
化驗
≥99%
形狀
liquid
自燃溫度
914 °F
包含
4-tert-butylcatechol as stabilizer
expl. lim.
6.1 %
折射率
n20/D 1.546 (lit.)
bp
145-146 °C (lit.)
mp
−31 °C (lit.)
密度
0.906 g/mL at 25 °C
儲存溫度
2-8°C
SMILES 字串
C=Cc1ccccc1
InChI
1S/C8H8/c1-2-8-6-4-3-5-7-8/h2-7H,1H2
InChI 密鑰
PPBRXRYQALVLMV-UHFFFAOYSA-N
正在寻找类似产品? 访问 产品对比指南
一般說明
已有对从纺织印染废水处理厂(TDWTP)中除去苯乙烯的研究。Co-SBA-15在过氧化氢氧化苯乙烯过程中的催化潜力已有研究。通过气相色谱-质谱(GC-MS)和选择离子监测(SIM)对苯乙烯的不对称环氧化进行筛选已有报道。通过使用增溶的4,4′-二烷基取代的2,2′-联吡啶,可对苯乙烯进行均相原子转移自由基聚合(ATRP) ,从而生成成分确定的聚合物。使用催化钯/碳,氯苯和取代的氯苯与苯乙烯在水中的Heck反应,可得到1,2-二苯基乙烷。
應用
苯乙烯已用于制备成分确定的叔-丙烯酸丁酯、丙烯酸甲酯和苯乙烯的均聚物、二嵌段共聚物和三嵌段共聚物 。
苯乙烯已被用作测试苯乙烯样品,该研究涉及在聚(苯乙烯-嵌段-二甲基硅氧烷)(PSDMS)作为稳定剂存在下,可逆加成-断裂链转移(RAFT)控制子对苯乙烯在超临界二氧化碳中的RAFT聚合作用的影响。
其他說明
抑制剂随着时间的推移而逐渐消耗,特别是在较高温度条件下
法律資訊
ReagentPlus is a registered trademark of Merck KGaA, Darmstadt, Germany
訊號詞
Danger
危險分類
Acute Tox. 4 Inhalation - Aquatic Chronic 3 - Asp. Tox. 1 - Eye Irrit. 2 - Flam. Liq. 3 - Repr. 2 - Skin Irrit. 2 - STOT RE 1 Inhalation - STOT SE 3
標靶器官
hearing organs, Respiratory system
儲存類別代碼
3 - Flammable liquids
水污染物質分類(WGK)
WGK 2
閃點(°F)
89.6 °F - closed cup
閃點(°C)
32.0 °C - closed cup
個人防護裝備
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
Journal of nanoscience and nanotechnology, 14(9), 7234-7241 (2015-05-01)
The rapid preparation of SBA-15 with cobalt (Co) introduction was performed via the ultrasonic irradiation in combination with "pH-adjusting" method. The catalytic properties of the synthesized Co-SBA-15 were investigated by examining the oxidation of styrene with hydrogen peroxide. The effect
The preparation of t-butyl acrylate, methyl acrylate, and styrene block copolymers by atom transfer radical polymerization: Precursors to amphiphilic and hydrophilic block copolymers and conversion to complex nanostructured materials.
Journal of Polymer Science Part A: Polymer Chemistry, 38(S1), 4805-4820 (2000)
Se pu = Chinese journal of chromatography, 32(12), 1385-1389 (2015-04-24)
A screening method by gas chromatography-mass spectrometry (GC-MS) with selected ion monitoring (SIM) has been developed for asymmetric epoxidation of styrene. All samples were analyzed by GC-MS with the mode of SIM by using ethylbenzene as the internal standard, by
Chemosphere, 136, 50-55 (2015-05-02)
The occurrence and removal of benzene, toluene, ethylbenzene, xylenes, styrene and isopropylbenzene (BTEXSI) from 6 textile dyeing wastewater treatment plants (TDWTPs) were investigated in this study. The practical capacities of the 6 representative plants, which used the activated sludge process
Heterogeneous palladium-catalysed heck reaction of aryl chlorides and styrene in water under mild conditions.
Advanced Synthesis & Catalysis, 344(3-4), 348-354 (2002)
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门