For most protease inhibitors, such as leupeptin and aprotinin, doubling the concentration typically does not negatively impact the assay. However, with specific inhibitors like the DPPIV inhibitor referenced, higher concentrations can interfere with the assay, which is why additional instructions are provided. Other DPPIV inhibitors, such as Diprotin A, do not interfere at any concentration but are not as effective.
HMHEMAG-34K
MILLIPLEX® 人代谢激素磁珠板 - 代谢多重检测
The Human Metabolic Hormone Panel, using the Luminex xMAP technology, enables the simultaneous analysis of 13 protein biomarkers in human serum, plasma and cell/tissue culture samples.
别名:
human metabolic hormone immunoassay panel, luminex human metabolic hormone multiplex assay, millipore human metabolism multiplex kit
About This Item
推荐产品
物種活性
human
製造商/商標名
Milliplex®
assay range
accuracy: 101%
(Glucagon)
accuracy: 102%
(Leptin)
accuracy: 103%
(GIP)
accuracy: 103%
(GLP-1 (Total))
accuracy: 105%
(Ghrelin (Active))
accuracy: 106%
(MCP-1)
accuracy: 97%
(TNFα)
accuracy: 99%
(C-Peptide)
sensitivity: 0.5 pg/mL
(MinDC+2SD; TNF?)
sensitivity: 1.1 pg/mL
(MinDC+2SD; GIP)
sensitivity: 13 pg/mL
(MinDC+2SD; IL-6)
sensitivity: 14 pg/mL
(MinDC+2SD; Ghrelin (Active))
sensitivity: 14 pg/mL
(MinDC+2SD; MCP-1)
sensitivity: 146 pg/mL
(MinDC+2SD; PYY)
sensitivity: 15 pg/mL
(MinDC+2SD; Amylin (Total))
sensitivity: 16 pg/mL
(MinDC+2SD; C-Peptide)
sensitivity: 16 pg/mL
(MinDC+2SD; Glucagon)
sensitivity: 160 pg/mL
(MinDC+2SD; Insulin)
sensitivity: 2.4 pg/mL
(MinDC+2SD; GLP-1 (Active))
sensitivity: 2.9 pg/mL
(MinDC+2SD; PP)
sensitivity: 28 pg/mL
(MinDC+2SD; Amylin (Active))
sensitivity: 64 pg/mL
(MinDC+2SD; Leptin)
sensitivity: 7.3 pg/mL
(MinDC+2SD; GLP-1 (Total))
standard curve range: 0.69-500 pg/mL
(TNFα)
standard curve range: 1.4-1,000 pg/mL
(GIP)
standard curve range: 13.7-10,000 pg/mL
(Amylin (Active))
standard curve range: 13.7-10,000 pg/mL
(Amylin (Total))
standard curve range: 13.7-10,000 pg/mL
(Ghrelin (Active))
standard curve range: 13.7-10,000 pg/mL
(Glucagon)
standard curve range: 13.7-10,000 pg/mL
(IL-6)
standard curve range: 13.7-10,000 pg/mL
(MCP-1)
standard curve range: 13.7-10,000 pg/mL
(PYY)
standard curve range: 137-100,000 pg/mL
(Insulin)
standard curve range: 137-100,000 pg/mL
(Leptin)
standard curve range: 2.7-2,000 pg/mL
(GLP-1 (Active))
standard curve range: 2.7-2,000 pg/mL
(GLP-1 (Total))
standard curve range: 2.7-2,000 pg/mL
(PP)
standard curve range: 27.4-20,000 pg/mL
(C-Peptide)
inter-assay cv: <15%
intra-assay cv: <10%
(C-Peptide)
inter-assay cv: <15%
intra-assay cv: <10%
(GIP)
inter-assay cv: <15%
intra-assay cv: <10%
(GLP-1 (Active))
inter-assay cv: <15%
intra-assay cv: <10%
(GLP-1 (Total))
inter-assay cv: <15%
intra-assay cv: <10%
(Ghrelin (Active))
inter-assay cv: <15%
intra-assay cv: <10%
(Glucagon)
inter-assay cv: <15%
intra-assay cv: <10%
(IL-6)
inter-assay cv: <15%
intra-assay cv: <10%
(Insulin)
inter-assay cv: <15%
intra-assay cv: <10%
(Leptin)
inter-assay cv: <15%
intra-assay cv: <10%
(MCP-1)
inter-assay cv: <15%
intra-assay cv: <10%
(PP)
inter-assay cv: <15%
intra-assay cv: <10%
(PYY)
inter-assay cv: <15%
intra-assay cv: <10%
(TNFα)
inter-assay cv: <20%
intra-assay cv: <10%
(Amylin (Active))
inter-assay cv: <20%
intra-assay cv: <10%
(Amylin (Total))
技術
multiplexing: suitable
檢測方法
fluorometric (Luminex xMAP)
運輸包裝
wet ice
一般說明
MILLIPLEX®人体代谢激素面板是一种15种分析物,13重试剂盒,用于同时定量血清、血浆和细胞/组织培养样品中以下分析物的任何或全部:胰淀素(活性)或胰淀素(总计),C肽,胃饥饿素(活性),GIP,GLP-1(活性)或GLP-1(总计),胰高血糖素,IL-6,胰岛素,瘦素,MCP-1,PP,PYY,TNFα。该试剂盒采用96孔板,包含冻干标准混合物、两个内部检测质控品,可最多可测定38份样本,重复两次。
Luminex® xMAP®平台使用磁珠免疫分析格式,以实现理想的速度和灵敏度,同时定量多种分析物,从而显著提高生产力,同时节省宝贵的样本量。
面板类型:代谢
應用
- 分析物:胰淀素(活性)或胰淀素(总计),C肽,胃饥饿素(活性),GIP(总计),GLP-1(活性)、GLP-1(总计),胰高血糖素,IL-6,胰岛素,瘦素,MCP-1(CCL2),胰多肽(PP),PYY(总计),TNF-α
- 注释:不能同时测定以下分析物:胰淀素(活性)& 胰淀素(总计);GLP-1(活性)& GLP-1(总计)。
- 推荐的样品类型:人血清、血浆和细胞/组织培养上清液或裂解液
- 推荐的样品稀释液:每孔25μ L未稀释的血清或血浆;细胞/组织培养样品可以未经稀释使用,也可以用适当的对照培养基稀释使用。注意:以下分析物需要向血清或血浆样品中添加蛋白酶抑制剂(详见方案中的样品采集和储存部分):GLP-1(DPPIV抑制剂);胰淀素(蛋白酶抑制剂混合物);胰高血糖素(抑肽酶);胃饥饿素(活性)(丝氨酸蛋白酶抑制剂)
- 分析运行时间:在2-8℃下过夜(16-18小时)
- 研究类别:代谢
- 研究子类别:代谢紊乱
特點和優勢
聯結
其他說明
法律資訊
訊號詞
Danger
危險分類
Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Irrit. 2 - Skin Sens. 1
儲存類別代碼
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
相关内容
Multiplex immunoassays, such as MILLIPLEX® multiplex metabolic assays, are critical in metabolic syndrome research because they provide a full picture of the different conditions related to it, like diabetes and obesity, as well as save time and sample volume.
-
How much protease inhibitor should be added when using only the plasma instead of the entire blood sample?
1 answer-
Helpful?
-
-
Could you please provide information on the epitopes targeted by the antibodies HMHE-1034-2 and HMHE-1034-1, which are used in the MILLIPLEX MAP Human Metabolic Hormone Magnetic Bead Panel - Metabolism Multiplex Assay? Specifically, I would like to know if the anti-GLP-1 antibody would be able to bind to a commercial drug such as semaglutide.
1 answer-
This antidiabetic medication for the treatment of type 2 diabetes and as anti-obesity medication for long-term weight management is known as Semaglutide. It is sold under the brand names Ozempic, Wegovy, and Rybelsus. Semaglutide was developed by Novo Nordisk in 2012. It is a GLP-1 receptor agonist, meaning that it mimics the action of the human incretin glucagon-like peptide-1 (GLP-1), thereby increasing insulin secretion and increasing blood sugar disposal and improving glycemic control.
Helpful?
-
Active Filters
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门