跳转至内容
Merck
所有图片(1)

主要文件

1.01207

Supelco

磷酸氢二铵

for analysis EMSURE® ACS,Reag. Ph Eur

别名:

磷酸氢二铵

登录查看公司和协议定价

选择尺寸

500 G
$257.00
25 KG
$7,890.00

$257.00


预计发货时间2025年6月10日详情


获取大包装报价

选择尺寸

变更视图
500 G
$257.00
25 KG
$7,890.00

About This Item

线性分子式:
(NH4)2HPO4
CAS号:
分子量:
132.06
MDL编号:
UNSPSC代码:
12352301
EC索引号:
231-987-8
NACRES:
NA.21

$257.00


预计发货时间2025年6月10日详情


获取大包装报价

等级

ACS reagent

质量水平

Agency

reag. Ph. Eur.

产品线

EMSURE®

方案

≥99.0% (acidimetric)

表单

solid

效能

6500 mg/kg LD50, oral (Rat)
>7950 mg/kg LD50, skin (Rabbit)

杂质

≤0.005% Insoluble matter

pH值(酸碱度)

7.6-8.2 (20 °C, 100 g/L in H2O)

溶解性

690 g/L

密度

1.619 g/cm3 at 20 °C

堆积密度

800‑1000 kg/m3

痕量阴离子

chloride (Cl-): ≤0.0005%
nitrate (NO3-): ≤0.001%
sulfate (SO42-): ≤0.004%

痕量阳离子

Ca: ≤0.001%
Fe: ≤0.001%
K: ≤0.001%
Mg: ≤0.0005%
Na: ≤0.001%
heavy metals (as Pb): ≤0.0005%

储存温度

2-30°C

SMILES字符串

[P](=O)([O-])([O-])[O-].[N+H4].[N+H4].[H+]

InChI

1S/2H3N.H3O4P/c;;1-5(2,3)4/h2*1H3;(H3,1,2,3,4)

InChI key

MNNHAPBLZZVQHP-UHFFFAOYSA-N

正在寻找类似产品? 访问 产品对比指南

相关类别

应用


  • 以溶液燃烧技术合成的羟基磷灰石的物相演变和烧结动力学: 本研究讨论了生物陶瓷中的关键材料羟基磷灰石的物相演变和烧结行为,着重介绍了溶液燃烧合成过程中涉及的化学过程,该过程中可能以括磷酸氢二铵为前体(Pratihar et al., 2006)。


  • 羟基磷灰石(HA)和磷酸三钙(TCP)生物陶瓷的化学合成和高温烧结行为研究。: 本文研究了羟基磷灰石和磷酸三钙等生物陶瓷的合成路线,在生产过程中可能要使用磷酸氢二铵,研究重点考察了它们在高温下的行为(Taş et al., 1997)。


联系

替代品:AX1355-1; AX1355

分析说明

含量(酸度): ≥ 99.0 %
不溶物: ≤ 0.005%
pH值(5 %;水; 25 °C):7.8-8.1
pH值(20 %;水):约8
氯化物(Cl): ≤ 0.0005%
硝酸盐(NO₃): ≤ 0.001%
硫酸盐: ≤ 0.004 %
重金属(以铅计): ≤ 0.0005 %
Ca(钙): ≤ 0.001 %
Fe(铁): ≤ 0.001 %
K(钾): ≤ 0.001 %
Mg(镁): ≤ 0.0005%
Na(钠): ≤ 0.001%
符合ACS试剂 Ph Eur

法律信息

EMSURE is a registered trademark of Merck KGaA, Darmstadt, Germany

储存分类代码

11 - Combustible Solids

WGK

WGK 1

闪点(°F)

Not applicable

闪点(°C)

Not applicable


分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Questions

1–3 of 3 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  3. Is original manufacturer information available for product number 1.01207? I don't see a dossier for it on the website.

    1 answer
    1. Product No. 1.01207 (di-Ammonium hydrogen phosphate, for analysis EMSURE® ACS,Reag. Ph Eur) is manufactured by Merck KGaA, Darmstadt, Germany under the Supelco® analytical products portfolio.

      Additional information on EMSURE® Inorganics and Solvents can be found under the "More Documents" section of the product details page for 1.01207: https://www.sigmaaldrich.com/product/mm/101207#product-documentation