跳转至内容
Merck

429252

Sigma-Aldrich

聚(对苯二甲酸)

granular

别名:

PET

登录查看公司和协议定价


About This Item

线性分子式:
(C10H8O4)n
CAS号:
MDL號碼:
分類程式碼代碼:
12162002
PubChem物質ID:
NACRES:
NA.23

耐磨強度

30 mg (Taber, CS-17 wheel, 1kg, 50% RH, 1,000 cycles)

品質等級

描述

30% glass fiber to enhance hardness and strength

形狀

granular

硬度

120 (Rockwell R, ASTM D 785)

mp

250-255 °C

密度

1.68 g/mL at 25 °C

SMILES 字串

OCCO.OC(=O)c1ccc(cc1)C(O)=O

InChI

1S/C8H6O4.C2H6O2/c9-7(10)5-1-2-6(4-3-5)8(11)12;3-1-2-4/h1-4H,(H,9,10)(H,11,12);3-4H,1-2H2

正在寻找类似产品? 访问 产品对比指南

應用

用于电气部件,包括继电器底座和灯座、泵壳、齿轮、链轮、椅子扶手、脚轮和家具部件。

特點和優勢

平衡的强度、刚度和韧性,优异的电气性能、表面外观和耐化学性。

儲存類別代碼

11 - Combustible Solids

水污染物質分類(WGK)

WGK 3

閃點(°F)

Not applicable

閃點(°C)

Not applicable

個人防護裝備

Eyeshields, Gloves, type N95 (US)


历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Leonardo Pantoja Munoz et al.
Environmental science and pollution research international, 25(20), 20268-20279 (2018-06-28)
The introduction to the market of wet wipes, advertised and labelled as "flushable", has been the subject of controversy due to their perceived potential to block sewer systems as observed with other non-woven cloths such as traditional non-flushable wipes. Non-woven
A Abdollahi et al.
Hernia : the journal of hernias and abdominal wall surgery, 14(6), 569-573 (2010-08-10)
The use of prosthetic materials has become the standard of care in the management of incisional hernias because of its association with a low rate of recurrence. In this paper, the results of the treatment of incisional hernias is reported.
J M C Brown et al.
Journal of environmental radioactivity, 102(10), 901-905 (2010-10-29)
An energy discriminate CR-39(®) nuclear track etch dosimeter for use in a (220)Rn and (222)Rn gas monitor has been developed and experimentally assessed. It utilises a thin film of Mylar(®) C to attenuate the alpha particle energies to allow only
Andrew J Stein et al.
Techniques in hand & upper extremity surgery, 15(1), 12-15 (2011-03-02)
Many surgical procedures have been described for the treatment of thumb basilar joint osteoarthritis. Augmentation of the standard ligament reconstruction tendon interposition procedure with the use of a Mersilene suture tape suspension-plasty, to recreate the stability provided by the anterior
Jonathan M Holmes et al.
Journal of AAPOS : the official publication of the American Association for Pediatric Ophthalmology and Strabismus, 14(2), 132-136 (2010-05-11)
Some authors have suggested that a posterior fixation suture on the lateral rectus muscle is ineffective because of the muscle's long arc of contact with the globe. We report a small case series of patients successfully treated using a lateral

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门