Przejdź do zawartości
Merck

D0405

Sigma-Aldrich

Dialysis tubing, high retention seamless cellulose tubing

avg. flat width 23 mm (0.9 in.), MWCO 14000, 99.99% retention

Synonim(y):

Dialysis tubing

Zaloguj sięWyświetlanie cen organizacyjnych i kontraktowych


About This Item

Kod UNSPSC:
41123100
NACRES:
NB.22

średnia śr.

15 mm , when full

średnia szerokość na płasko

23 mm (0.9 in.)

pojemność

~50 mL/ft

wielkość porów

14000 MWCO, 99.99% retention

Szukasz podobnych produktów? Odwiedź Przewodnik dotyczący porównywania produktów

Opis ogólny

Retains >99% of cytochrome c (M.W. 12,400) in solution over a 10-hour period.

Opakowanie

Supplied in rolls, dry

Jakość

May contain glycerin and sulfur compounds in more than trace amounts; washing instructions are included.

Uwaga dotycząca przygotowania

Removal of glycerol included as a humectant can be accomplished by washing the tubing in running water for 3-4 hours. Removal of sulfur compounds can be accomplished by treating the tubing with a 0.3% (w/v) solution of sodium sulfide at 80°C for 1 minute. Wash with hot water (60°C) for 2 minutes, followed by acidification with a 0.2% (v/v) solution of sulfuric acid, then rinse with hot water to remove the acid. This tubing will retain most proteins of molecular weight 12,000 or greater.

Certyfikaty analizy (CoA)

Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.

Masz już ten produkt?

Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.

Odwiedź Bibliotekę dokumentów

Inge Pietersen et al.
Pathogens (Basel, Switzerland), 9(12) (2020-12-03)
Vaccine efficacy requires the production of neutralising antibodies which offer protection against the native virus. The current gold standard for determining the presence of neutralising antibodies is the pseudovirion-based neutralisation assay (PBNA). PBNAs utilise pseudovirions (PsVs), structures which mimic native
Ahmet Dogrul et al.
Journal of microencapsulation, 31(5), 448-460 (2014-04-05)
The purpose of this study was to develop a water/oil microemulsion containing lidocaine hydrochloride (4%) and to compare its local anaesthetic efficacy with commercial products. A pseudoternary diagram (Km:1/1 or 1/2) was constructed using lecithin/ethanol/oil/water. The droplet size, viscosity and
Mojgan Allahyari et al.
Journal of immunological methods, 416, 157-166 (2014-12-02)
Recombinant antigens are increasingly applied to replace native antigens in serological tests. Surface antigen 1 (SAG1) is a highly immunogenic antigen and probably represents the most explored and used antigen of Toxoplasma gondii for development of serological test kits. The

Powiązane treści

Przewody do dializy

Dialysis Tubing

Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.

Skontaktuj się z zespołem ds. pomocy technicznej