Przejdź do zawartości
Merck

GF41812286

Lead

foil, 1m coil, thickness 0.15mm, as rolled, 99.95%

Synonim(y):

Lead, PB000350

Zaloguj sięWyświetlanie cen organizacyjnych i kontraktowych


About This Item

Wzór empiryczny (zapis Hilla):
Pb
Numer CAS:
Masa cząsteczkowa:
207.20
Numer MDL:
Kod UNSPSC:
12141723
Identyfikator substancji w PubChem:
NACRES:
NA.23

Próba

99.95%

Postać

foil

producent / nazwa handlowa

Goodfellow 418-122-86

rezystywność

20.65 μΩ-cm

dł. × grubość

1 m × 0.15 mm

tw

1740 °C (lit.)

mp

327.4 °C (lit.)

ciąg SMILES

[Pb]

InChI

1S/Pb

Klucz InChI

WABPQHHGFIMREM-UHFFFAOYSA-N

Powiązane kategorie

Opis ogólny

For updated SDS information please visit www.goodfellow.com.

Informacje prawne

Product of Goodfellow

Piktogramy

Health hazardEnvironment

Hasło ostrzegawcze

Danger

Zwroty wskazujące rodzaj zagrożenia

Zwroty wskazujące środki ostrożności

Klasyfikacja zagrożeń

Aquatic Acute 1 - Aquatic Chronic 1 - Lact. - Repr. 1A - STOT RE 1 Oral

Organy docelowe

Central nervous system,Blood,Immune system,Kidney

Kod klasy składowania

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

Klasa zagrożenia wodnego (WGK)

nwg

Temperatura zapłonu (°F)

Not applicable

Temperatura zapłonu (°C)

Not applicable


Certyfikaty analizy (CoA)

Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.

Masz już ten produkt?

Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.

Odwiedź Bibliotekę dokumentów

M Bourgeois et al.
Health physics, 62(6), 546-552 (1992-06-01)
A significant amount of radiation escapes the rear of an image receptor in conventional dental radiographic procedures despite the placement of a lead-containing backing at the rear of the film pack. The purpose of this investigation was to place additional
Motoaki Kato et al.
Nihon Hoshasen Gijutsu Gakkai zasshi, 61(8), 1158-1169 (2005-09-01)
In projection radiography, stationary grids are indispensable accessories to the improvement of diagnostic imaging. On the other hand, they are becoming one of the issues facing digital image processing. The lead foil that composes the grid can produce moiré on
D W Rogers
Medical physics, 26(4), 533-537 (1999-05-05)
Data are presented to allow the photon beam quality specifier being used in the new AAPM TG-51 protocol, %dd(10)x, to be extracted from depth-dose data measured with a 1 mm lead foil either 50 cm or 30 cm from the
X A Li et al.
Medical physics, 26(7), 1245-1251 (1999-08-06)
The purpose of this work is to study the dose enhancement by a thin foil (thickness of 0.2-4 mm) of high-Z material in a water phantom, irradiated by high-energy photon beams. EGS4 Monte Carlo technique was used. Perturbations on the
A Janhom et al.
Dento maxillo facial radiology, 29(1), 20-27 (2000-02-02)
To determine the interaction between image noise and file compression, with special emphasis on the accuracy of caries diagnosis. Fifty-nine bitewing radiographs of patients were taken simultaneously with Ektaspeed Plus (Eastman-Kodak, Rochester, NY, USA) film without lead foil and the

Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.

Skontaktuj się z zespołem ds. pomocy technicznej