Saltar al contenido
Merck
Todas las fotos(1)

Documentos clave

25467

Supelco

Columna capilar para GC Carboxen®-1010 PLOT

Carboxen®-1010 PLOT Capillary GC Column

L × I.D. 30 m × 0.53 mm, average thickness 30 μm

Sinónimos:

Carboxen® 1010 PLOT Column, 30m x 0.53mm

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Número CE:
Código UNSPSC:
41115710
eCl@ss:
32119290
En este momento no podemos mostrarle ni los precios ni la disponibilidad

Materiales

fused silica

Agency

ASTM® D3612-96

descripción

PLOT = Porous Layer Open Tubular

fabricante / nombre comercial

Carboxen®

Parámetros

≤25-250 °C temperature (isothermal or programmed)

grosor promedio

30 μm

df

30 μm

técnicas

gas chromatography (GC): suitable

L × D.I.

30 m × 0.53 mm

grupo activo de la matriz

Carbon molecular sieve phase

aplicaciones

chemicals and industrial polymers
food and beverages

tipo de columna

capillary PLOT

¿Está buscando productos similares? Visita Guía de comparación de productos

Descripción general

Application: This column is ideal for the separation of all major components in permanent gas (helium, hydrogen, oxygen, nitrogen, carbon monoxide, methane, and carbon dioxide) and light hydrocarbons (C2-C3) in the same analysis. It is the only column commercially available that is able to separate all major components in permanent gas. This column can also separate oxygen from nitrogen at subambient temperatures.
USP Code: None
Phase:
  • Carbon molecular sieve
Temp. Limits:
  • Subambient to 250 °C (isothermal or programmed)
Carboxen® Adsorbent is ideally used for solid-phase microextraction (SPME)[1] and does highly efficient extraction of small polar molecules from aqueous solution.[2] Porous-layer open-tubular (PLOT) columns are a powerful tool employed in gas chromatography during analysis of fixed gases, light hydrocarbons and volatile solvents. They are mostly preferred over traditional packed columns.[3]

Otras notas

We offer a variety of chromatography accessories including analytical syringes

Información legal

ASTM is a registered trademark of American Society for Testing and Materials
Carboxen is a registered trademark of Merck KGaA, Darmstadt, Germany

Aplicación

Referencia del producto
Descripción
Precios

Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Los clientes también vieron

Applications of Solid Phase Microextraction
Pawliszyn J.
Applications of Solid Phase Microextraction, 64-65 (1999)
Porous layer open-tubular capillary columns: preparations, applications and future directions.
Zhenghua Ji
Journal of Chromatography A, 842 (1), 115-142 (1999)
B D Page et al.
Journal of chromatography. A, 873(1), 79-94 (2000-04-11)
The headspace solid-phase microextraction (HS-SPME) efficiencies from vegetable oil of the recently available Carboxen-poly(dimethylsiloxane) (PDMS) and divinylbenzene-Carboxen-PDMS fibres were found to be much greater than those of the PDMS fibre for a number of volatile contaminants. Using these Carboxen-based fibres
Dawn M Chapman et al.
Journal of agricultural and food chemistry, 52(17), 5431-5435 (2004-08-19)
A rapid and automated solid phase microextraction (SPME) stable isotope dilution gas chromatography/mass spectrometry (GC-MS) method for 2-methoxy-3-isobutylpyrazine (MIBP) quantification in red wine was developed. Wines with 30% (w/v) NaCl and 2-methoxy-(2)H(3)-3-isobutylpyrazine internal standard were sampled with a 2 cm
Lucia Giordano et al.
Journal of chromatography. A, 1017(1-2), 141-149 (2003-10-31)
A new method was developed for the determination of 2-furfural (2-F) and 5-methylfurfural (5-MF), two products of Maillard reaction in vinegar, with head-space solid-phase microextraction (HS-SPME) coupled to gas chromatography-mass spectrometry (GC-MS). A divinylbenzene (DVB)/carboxen (CAR)/polydimethylsiloxane (PDMS) fibre was used

Questions

1–9 of 9 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  3. What are the specific functional groups that may affect the separation and the carbon saturated/unsaturated ratio of the material used in the Carboxen 1010 PLOT capillary column?

    1 answer
    1. The material used in the Carboxen 1010 PLOT capillary column does not retain any functional groups after the synthesis process due to the high temperatures involved. The carbon surface consists mainly of carbon and hydrogen, with very few exceptions.

      Helpful?

  4. Are there specific installation instructions available for the Carboxen-1010 plot column 24246, particularly regarding whether it needs to be baked out before use?

    1 answer
    1. The installation of capillary columns can differ based on the gas chromatography brand, detector type, injection port, and insertion distance. It's advisable to consult the GC manual for column insertion distance information and any special adapters required before installation.

      Helpful?

  5. Is the Carboxen 1010 PLOT column, Product 25467, GC/MS compatible?

    1 answer
    1. Yes, the particles are very strongly adhered to the surface of the column and would be compatible with mass spec detection.

      Helpful?

  6. What is the film thickness of the Carboxen™-1010 PLOT Capillary GC Column, Product 25467?

    1 answer
    1. The film thickness for this column is 30um.  The term "film" is somewhat of a misnomer because it is actually a layer of solid carboxen particles adhered to the fused silica tubing.

      Helpful?

  7. How can I purchase a column that is packed with this material?

    1 answer
    1. Most packed column are custom made and require that you obtain a quotation. Please contact our Customer & Sales Services group at phone number (800)-247-6628, fax number (800)-447-3044 or email [email protected] for additional information.

      Helpful?

  8. What types of compounds would be suitable for analysis on the Carboxen™-1010 PLOT Capillary GC Column, Product 25467?

    1 answer
    1. This column is designed for the analysis of permanent gases and light hydrocarbons up to a maximum of 3 carbon units.

      Helpful?

  9. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?

Reviews

Active Filters

  1. Sydney, Australia
    • Review 1
    • Votes 0
    5 out of 5 stars.

    Carboxen®-1010 PLOT Capillary GC Column

    Having used another similar column (different manufacturer) for the separation of H2, CO, CO2 and ethylene, I find this column to exhibit very good stability and reliability. Certainly, the high operational temperature rating is most welcomed.

    Helpful?

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico