Saltar al contenido
Merck

MSMLS

Sigma-Aldrich

Banco de metabolitos para espectrometría de masa

Supplied by IROA Technologies

Sinónimos:

Banco de metabolitos, Banco metabólico, MSMLS, Mass Spectrometry Metabolite Libarary de patrones

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

UNSPSC Code:
41116107
NACRES:
NA.25
En este momento no podemos mostrarle ni los precios ni la disponibilidad

packaging

pkg of 7 plates

manufacturer/tradename

IROA Technologies

plate size

96 wells

suitability

suitable for mass spectrometry

application(s)

lipidomics
metabolomics
microbiology

shipped in

dry ice

storage temp.

−20°C

¿Está buscando productos similares? Visita Guía de comparación de productos

General description

Los compuestos MSMLS se proporcionan cómodamente en 5μg por pocillo, suficiente para múltiples inyecciones. Son compuestos de gran pureza (>95 %) suministrados en un formato económico y fácil de utilizar. Los compuestos están organizados en 7 gradillas de polipropileno. Los descriptores de los metabolitos suministrados con el producto son: Nombre, CID del progenitor, fórmula molecular, peso molecular, CAS, ChEBI, ID HMDB, ID de compuesto y de sustancia PubChem.

MSMLS (Mass Spectrometry Metabolite Library) es una colección de moléculas bioquímicas pequeñas de gran calidad utilizadas para aplicaciones de espectrometría de masas en metabolómica, y proporciona una amplia representación del metabolismo primario.

Application

Mass Spectrometry Metabolite Library se utiliza con mucha más frecuencia para proporcionar tiempos de retención y espectros de compuestos metabólicos fundamentales, contribuir a optimizar los protocolos analíticos de la espectrometría de masas y cualificar y cuantificar la sensibilidad y el límite de detección de la espectrometría de masas.[1][2]

Features and Benefits

Más de 600 metabolitos de pequeño tamaño organizados en un formato de 96 pocillos Si desea ver una lista completa de los compuestos de la biblioteca para lotes recientes, descargue los mapas de placas siguientes:

  • MSMLS-LOT-230-23
  • MSMLS-LOT-230-16
  • MSMLS-LOT-230-13

    Al descargar el software se suministra el mapa de placas completo con nombre, CID del progenitor, fórmula molecular, peso molecular, CAS, ChEBI, ID HMDB, ID de compuesto y de sustancia PubChem.

    Amplio espectro de metabolitos, metabolitos primarios e intermediarios fundamentales que abarcan las principales vías metabólicas, incluidas los siguientes clases de compuestos:
  • Ácidos carboxílicos, aminoácidos
  • Aminas biógenas, poliaminas
  • Nucleótidos, coenzimas y vitaminas
  • Monosacáridos y disacáridos
  • Ácidos grasos, lípidos, esteroides y hormonas

Suitability

Adecuado para secuencias de trabajo manuales y automatizadas.

Preparation Note

Los compuestos MSMLS se proporcionan cómodamente en 5μg por pocillo, suficiente para múltiples inyecciones. Los compuestos pueden utilizarse como patrones e inyectarse individualmente, o puede emplearse una estrategia para combinar los compuestos por filas para permitir el análisis de mezclas múltiples por inyección. Para más información sobre MSMLS, solubilización y notas de preparación, consulte la ficha de información del producto en la parte superior de la página.

Other Notes

Para descargar el paquete de software, pulse aquí - software MLSDiscovery.




Para ver el vídeo MLSDiscovery, visite: MLSDiscovery Tutorial Video.
Si desea más información sobre nuestra gama de productos bioquímicos, cumplimente este formulario.

Recommended products

Un nuevo kit de colección de metabolitos que contará con más de 500 metabolitos únicos de pequeño tamaño. Contiene 1 mg de cada metabolito. Esta colección de patrones se utiliza con más frecuencia para la cualificación y la cuantificación de los metabolitos por MS y NMR, análisis funcionales celulares y cribado fenotípico. Pulse aquí si desea más información.

Legal Information

MLSDiscovery is a trademark of IROA Technologies LLC
MSMLS is a trademark of IROA Technologies LLC

related product

Referencia del producto
Descripción
Precios

signalword

Danger

Hazard Classifications

Acute Tox. 1 Dermal - Acute Tox. 2 Inhalation - Acute Tox. 4 Oral - Aquatic Acute 1 - Aquatic Chronic 1 - Carc. 1B - Eye Dam. 1 - Lact. - Muta. 2 - Repr. 1A - Resp. Sens. 1 - Skin Corr. 1 - Skin Sens. 1 - STOT RE 1 - STOT RE 2 - STOT RE 2 Oral - STOT SE 2 - STOT SE 3

target_organs

Blood, Immune system, Respiratory system, Thyroid,Cardio-vascular system,Kidney

Storage Class

6.1A - Combustible acute toxic Cat. 1 and 2 / very toxic hazardous materials

flash_point_f

-40.0 °F

flash_point_c

-40 °C


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

A three-minute method for high-throughput quantitative metabolomics and quantitative tracing experiments of central carbon and nitrogen pathways.
Nemkov T, et al.
Rapid Communications in Mass Spectrometry, 31(8), 663-673 (2017)
Grégory Pimentel et al.
The Journal of nutrition, 148(6), 851-860 (2018-05-23)
Fermentation is a widely used method of natural food preservation that has consequences on the nutritional value of the transformed food. Fermented dairy products are increasingly investigated in view of their ability to exert health benefits beyond their nutritional qualities.
Matthieu Bergé et al.
eLife, 9 (2020-03-10)
Proliferating cells must coordinate central metabolism with the cell cycle. How central energy metabolism regulates bacterial cell cycle functions is not well understood. Our forward genetic selection unearthed the Krebs cycle enzyme citrate synthase (CitA) as a checkpoint regulator controlling
Pradeep Narayanaswamy et al.
Molecular omics, 16(5), 436-447 (2020-06-11)
We have developed MetaboKit, a comprehensive software package for compound identification and relative quantification in mass spectrometry-based untargeted metabolomics analysis. In data dependent acquisition (DDA) analysis, MetaboKit constructs a customized spectral library with compound identities from reference spectral libraries, adducts
Federica Fiorini et al.
Marine drugs, 18(6) (2020-06-18)
Pseudo-nitzschia multistriata is a planktonic marine diatom with a diplontic life cycle comprising a short sexual phase, during which gametes are produced following the encounter of two diploid cells of opposite mating type (MT). Gene expression studies have highlighted the

Protocolos

MSMLS™ offers high-purity small biochemical molecules for broad primary metabolism studies in an economical, ready-to-use format.

MSMLS™ offers high-purity small biochemical molecules for broad primary metabolism studies in an economical, ready-to-use format.

MSMLS™ offers high-purity small biochemical molecules for broad primary metabolism studies in an economical, ready-to-use format.

MSMLS™ offers high-purity small biochemical molecules for broad primary metabolism studies in an economical, ready-to-use format.

Contenido relacionado

We provide small molecule metabolite libraries and kits with a comprehensive range of primary metabolite compounds covering key metabolic pathways for your metabolomics research.

We provide small molecule metabolite libraries and kits with a comprehensive range of primary metabolite compounds covering key metabolic pathways for your metabolomics research.

We provide small molecule metabolite libraries and kits with a comprehensive range of primary metabolite compounds covering key metabolic pathways for your metabolomics research.

Ofrecemos kits y colecciones de metabolitos de pequeño tamaño con una completa gama de metabolitos primarios que cubren las vías metabólicas clave para su investigación en metabolómica.

Ver todo

Questions

1–3 of 3 Questions  
  1. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  3. Is it possible to dissolve the chemicals in pure water for the cell-free system in order to avoid the inclusion of other toxic solvents in the reaction when studying gene expression effects?

    1 answer
    1. The compounds are soluble in water and/or ethanol, although some, like cholesterol oleate, are not. In vitro experiments are generally not affected by adding a small amount of ethanol. Researchers interested in cell-based assays typically purchase the LSMLS.

      Helpful?

Reviews

No rating value

Active Filters

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico