UFC5003

Millipore

Filtro de ultracentrífuga Amicon®, MWCO 3 kDa

sample volume 0.5 mL, regenerated cellulose membrane, MWCO 3 kDa

Sinónimos:

Concentrador para centrífuga, MWCO de 3 kDa, volumen de muestra de 0,5 ml

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

UNSPSC Code:
41104916
eCl@ss:
36100101
NACRES:
NB.24
En este momento no podemos mostrarle ni los precios ni la disponibilidad

material

polypropylene cap
polypropylene tube
regenerated cellulose membrane
styrene-butadiene housing

Quality Level

sterility

non-sterile

product line

Amicon®

manufacturer/tradename

Amicon® Ultra

parameter

0.5 mL sample volume

technique(s)

protein extraction: suitable
protein purification: suitable

L

4.99 cm (1.96 in.)

diam.

10.8 mm

filtration area

1 cm2

volume

0.5 mL

pore size

3 kDa MWCO

shipped in

ambient

General description

Las unidades de filtración mediante centrífuga Amicon® Ultra-0,5 proporcionan una ultrafiltración rápida, con la capacidad de altos factores de concentración y una fácil recuperación de los concentrados de las matrices de muestras diluidas y complejas. Por ejemplo, el citocromo C (12,4 kDa) a una concentración inicial de 0,25 mg/ml es retenido normalmente al >95 %.

El diseño vertical y la superficie de membrana disponible proporcionan un procesamiento rápido de la muestra, una elevada recuperación de la muestra (normalmente superior al 90 % de la disolución inicial diluida) y la capacidad de concentración de 30 veces. La polarización del soluto y el consiguiente ensuciamiento de la membrana se reducen al mínimo gracias al diseño vertical, y un bloqueo físico del filtro evita la centrifugación hasta la sequedad y la posible pérdida de muestra. La recuperación eficiente de la muestra concentrada (especies retenidas) se consigue mediante una cómoda etapa de espín inverso después de recoger el filtrado.

Las unidades Amicon® Ultra-0,5 se suministran sin esterilizar y son para un solo uso. Con su diseño de membrana vertical y espín inverso, los filtros Amicon® Ultra de 0,5 ml ofrecen un gran rendimiento y menores tiempos de centrifugado.

Application

  • Ultrafiltración con membrana Ultracel® de corte de peso molecular de 3 000 dalton
  • Concentración de muestras biológicas que contienen antígenos, anticuerpos, enzimas, ácidos nucleicos o microorganismos
  • Purificación de los componentes macromoleculares que se encuentran en extractos de cultivo tisular o lisados celulares, eliminación de cebadores, conectores o etiquetas macromoleculares de una mezcla de reacción y eliminación de las proteínas antes de la HPLC
  • Desalación, cambio de la disolución tampón y diálisis de proteínas

Features and Benefits

  • La membrana de celulosa regenerada Ultracel® con un NMWCO de 3 kDa proporciona una recuperación del retenido superior al 90 %
  • Concentra desde 500 μl hasta 15 μl.
  • Factor de concentración 25x a 30x
  • Elevada recuperación de la muestra (superior al 90 % de la disolución diluida inicial)
  • Tiempo de procesamiento rápido: 10 a 30 minutos
  • La capacidad de espín inverso proporciona recuperaciones uniformes

Physical form

Código de colores: Transparente

Legal Information

Amicon is a registered trademark of Merck KGaA, Darmstadt, Germany
ULTRACEL is a registered trademark of Merck KGaA, Darmstadt, Germany

Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Artículos

Commercially available protein labeling kits provide researchers with the flexibility to customize their own immunoassay detection panels.

Protein purification is simpler with Amicon Pro. The device delivers consistent sample preparation for more reliable recovery, uncompromised purity and easier data generation.

Filtration methods and membrane filter selection in nanoparticle purification and production.

Filtration methods and membrane filter selection in nanoparticle purification and production.

Ver todo

Protocolos

If an antibody must be purified from a small sample volume (0.5-10 mL), then the Amicon® Pro Purification System is recommended.

Detergents are frequently used to solubilize proteins and nucleic acids during purification, but the presence of detergents may interfere with downstream analyses.

Contenido relacionado

Concentrate protein, don’t lose it. Recover protein reliably when you concentrate with Amicon® Ultra filters.

Questions

1–7 of 7 Questions  
  1. What is the margin of error for the MWCO? I read somewhere the RECOMMENDATION is to use a MWCO 2-3x smaller than your target. But I was wondering what’s the standard deviation from 3 kDa?

    1 answer
    1. For most membranes, the nominal molecular weight limit, also referred to as the molecular weight cut-off, is determined experimentally under a standard set of operating conditions. These analyses typically employ purified globular proteins to serve as markers or indicators of the retention characteristics of an ultrafiltration membrane. An ultrafiltration membrane with a stated nominal molecular weight limit should retain (reject) at least 90% of a globular solute of that molecular weight in daltons. However, for a wider safety margin, the selected cut-off should be well below the molecular weight of the solute to be retained. It is recommended to use a cut-off 2-3 times smaller than the molecular weight of the protein to be concentrated.

      Helpful?

  2. Is this product compatible with organic solvents, such as DMSO or DMF?

    1 answer
    1. The Amicon Ultra products are suitable for use with samples containing up to 10% DMSO and 10% DMF. Exposure to 100% DMSO is not recommended. Unfortunately, the compatibility of these devices with 100% DMF has not been determined.

      Helpful?

  3. Can I order the filter only, coming with no tube part?

    1 answer
    1. Unfortunately, no, this product is not available as a stand alone item. The tubes are available separately under the product UFC50VL96.

      Helpful?

  4. Is the 0.5 ml 3KDa Amicon device (UFC5003) compatible with a solution containing 5% SDS (Sodium Dodecyl Sulfate)?

    1 answer
    1. The Amicon® Ultra centrifugal devices are designed for processing biological fluids and aqueous solutions. Amicon® Ultra Filter Devices are compatible with concentrations of Sodium dodecyl sulfate (SDS)of 0.1% or less. Prior to use, it is important to verify the chemical compatibility of the sample with the device.

      Helpful?

  5. Hi, Do these filters come with expiry dates? If so where would I be able to find them on the product?

    1 answer
    1. This product is not assigned an expiration date or recommended retest date. Products with no expiration date or recommended retest date should be routinely inspected by customers to ensure they perform as expected. These products are also subject to a one year warranty from the date of shipment. For more information you may access the "Product Dating Information" document under "ADDITIONAL USEFUL DOCUMENTS ABOUT OUR PRODUCTS" at the bottom of the Quality Services page with this link: https://www.sigmaaldrich.com/life-science/quality-and-regulatory-management/quality-services.

      Helpful?

  6. How long should I centrifugate at 14.000 g and how long for the reverse spin at 1000 g?

    1 answer
    1. Typical concentration time for the 3kD membrane device is approximately 30 minutes. However, spin times may need to be adjusted to either a shorter or longer time depending on the sample starting volume, initial concentration, composition, and desired minimum volume. The reverse spin is 1000g for 2 minutes. Please review the product user guide at the link below:
      https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/271/340/pr05485-rev0219.pdf

      Helpful?

  7. Hi, how many g's can be used for the ultracell-3K #UFC500396 product?

    1 answer
    1. The recommended speed with a 35 degree fixed angle rotor is 14,000 g with a reverse spin of 1000 g. This information can be found at this link: https://www.sigmaaldrich.com/products/protein-biology/protein-sample-prep/amicon-centrifugals#ultracentrifugal

      Helpful?

Reviews

No rating value

Active Filters

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico