Acerca de este artículo
material
polyethersulfone filter
Quality Segment
packaging
pkg of 1 unit
manufacturer/tradename
Millipak®
pore size
0.22 μm pore size
compatibility
for use with Milli-Q® EQ 7000, for use with Milli-Q® EQ 7008, for use with Milli-Q® EQ 7016, for use with Milli-Q® IX 7003, for use with Milli-Q® IX 7005, for use with Milli-Q® IX 7010, for use with Milli-Q® IX 7015, for use with Milli-Q® IQ 7000, for use with Milli-Q® IQ 7003, for use with Milli-Q® IQ 7005, for use with Milli-Q® IQ 7010, for use with Milli-Q® IQ 7015
shipped in
ambient
General description
El filtro está diseñado con una membrana de filtración asimétrica de PES (polietersulfona) de 0,22μm termosellada en una carcasa de estireno-acrilonitrilo que sirve para reducir al mínimo la liberación de extraíbles orgánicos e inorgánicos.
Application
Features and Benefits
- Cada filtro Millipak® de 0,22μm se prueba individualmente, se precinta herméticamente y se entrega con un certificado de calidad.
- Validado para el suministro de agua exenta de bacterias (<0.01cfu/mL when installed and used in a laminar flow hood).
- Carefree maintenance: Easily installed and replaced.
- Redesigned bottom-tip for a secured installation of the protection bell.
- Validated to deliver particulate-free water (no particles with size >0,22 μm)
- La etiqueta e-Sure para conexión RFID con el dispensador E-POD® o Q-POD® permite una trazabilidad completa (gestión de datos) y una supervisión automática del estado de los fungibles en la interfaz táctil del POD.
Other Notes
- Retención de organismos: microorganismos
- Modo de acción: filtración
- Aplicación: Análisis generales de laboratorio
- Indicaciones de uso: Purificación del agua
- Indicaciones de uso: Este artículo proporciona agua filtrada a través de membranas de grado esterilizante de 0,22 m. Consulte la sección «Utilización del sistema» de la guía del usuario del equipo (disponible en la memoria USB que encontrará en la caja del sistema)
- Condiciones de almacenamiento: Guardar en un lugar seco
- Consideraciones de eliminación: desechar de acuerdo con la normativa federal, estatal y local correspondiente.
Legal Information
1 of 1
Este artículo | |||
|---|---|---|---|
| compatibility for use with Milli-Q® EQ 7000, for use with Milli-Q® EQ 7016, for use with Milli-Q® IX 7005, for use with Milli-Q® IX 7015, for use with Milli-Q® IQ 7003, for use with Milli-Q® IQ 7010, for use with Milli-Q® IX 7003, for use with Milli-Q® IQ 7000, for use with Milli-Q® IQ 7015, for use with Milli-Q® IX 7010, for use with Milli-Q® EQ 7008, for use with Milli-Q® IQ 7005 | compatibility for use with Milli-Q® EQ 7008, for use with Milli-Q® EQ 7016, for use with Milli-Q® IX 7003, for use with Milli-Q® IX 7005, for use with Milli-Q® IX 7010, for use with Milli-Q® IX 7015, for use with Milli-Q® IQ 7003, for use with Milli-Q® IQ 7005, for use with Milli-Q® IQ 7010, for use with Milli-Q® IQ 7015 | compatibility for use with Milli-Q® EQ 7000, for use with Milli-Q® EQ 7008, for use with Milli-Q® EQ 7016, for use with Milli-Q® IX 7003, for use with Milli-Q® IX 7005, for use with Milli-Q® IX 7010, for use with Milli-Q® IX 7015, for use with Milli-Q® IQ 7000, for use with Milli-Q® IQ 7003, for use with Milli-Q® IQ 7005, for use with Milli-Q® IQ 7010, for use with Milli-Q® IQ 7015 | compatibility for use with Milli-Q® EQ 7008, for use with Milli-Q® EQ 7016, for use with Milli-Q® IX 7003, for use with Milli-Q® IX 7005, for use with Milli-Q® IX 7010, for use with Milli-Q® IX 7015, for use with Milli-Q® IQ 7003, for use with Milli-Q® IQ 7005, for use with Milli-Q® IQ 7010, for use with Milli-Q® IQ 7015 |
| pore size 0.22 μm pore size | pore size 0.45 μm pore size | pore size - | pore size - |
| manufacturer/tradename Millipak® | manufacturer/tradename - | manufacturer/tradename BioPak® | manufacturer/tradename - |
| packaging pkg of 1 unit | packaging pkg of 1 unit | packaging pkg of 1 unit | packaging pkg of 1 unit |
| Quality Level 300 | Quality Level 300 | Quality Level 300 | Quality Level - |
| shipped in ambient | shipped in ambient | shipped in ambient | shipped in - |
Still not finding the right product?
Explore all of our products under Filtro Millipak® de 0,22 μm
Certificados de análisis (COA)
Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
-
Where can I find information on proper disposal and recycling of Milli-Q consumables (e.g. millipak filters)?
1 answer-
Helpful?
-
-
What are the storage conditions for this product?
1 answer-
Recommended storage conditions: temperatures from 5 to 30°C; humidity between 10 and 80%. The original sealed bag (if provided) must be kept intact before the first use to protect the purification element from foreign matter.
Helpful?
-
-
How are consumables changed?
1 answer-
To help you to change your system's consumables, several video tutorials are available on our YouTube channel: https://youtube.com/playlist?list=PL2TUriaAaEA_IXDCnPbDk6OmrwptjwOHD. For high-flow systems, please keep in mind that all consumable changes must be approved by a 3-digit code that only the person in charge of the system knows.
Helpful?
-
-
How can I know which consumables can be used with my system?
1 answer-
To know which consumables can be used on your system, you can see in the user manual of your system or see all the consumables for each system listed on https://www.sigmaaldrich.com/products/water-purification/milli-q-consumables.
Helpful?
-
-
What steps are you taking towards improved sustainability?
1 answer-
Sustainability is at the heart of our innovations. From reducing water and energy consumption, to minimizing plastic and chemical waste, our dedicated water system engineers are constantly working on new ways to reduce the ecological footprint of our products to better support the sustainability goals we're all striving towards. For more information, we invite you to review the following brochure and infographic which highlight our efforts and achievements: https://www.sigmaaldrich.com/life-science/milliq#sus. Do not hesitate to contact your local representative or sales contact (https://www.sigmaaldrich.com/collections/offices) for further information.
Helpful?
-
-
Can I arrange to have my consumables automatically ordered and delivered once a year?
1 answer-
It's possible to place only one consumable order per year with a specific contract called "Consumable Supply Agreement (CSA)" (https://www.sigmaaldrich.com/US/en/products/water-purification/milli-q-consumables#csa). For further information, contact your local representative or sales contact (https://www.sigmaaldrich.com/US/en/collections/offices).
Helpful?
-
-
Can consumables be opened and refilled?
1 answer-
Unfortunately, this is not possible because of safety issues and the need to guarantee the quality of consumables and their interior purification components. Our consumables are manufactured in an ISO 9001-certified facility France in agreement with high quality standards.
Helpful?
-
-
Where can I find data sheets, Certificates of Origin, Certificates of Analysis, and Certificates of Quality?
1 answer-
Documents and certificates are available in the "Documentation" section on this page. Do not hesitate to contact us if you require further information.
Helpful?
-
-
What is the consumables delivery time?
1 answer-
Refer to the consumable's Product page for a first estimation of its expected delivery time and contact customer service for more information.
Helpful?
-
-
How frequently do the various consumables need to be changed?
1 answer-
The frequency that consumables must be changed depends on the system's usage (treated water volume) and on the consumables themselves (time of usage). In order to ensure the quality of water and your results, the consumables should be replaced when the system alerts you.
Helpful?
-