If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf
1.00519
Perchloric acid
70-72%, for analysis EMSURE® ACS,ISO,Reag. Ph Eur
Sinónimos:
Ácido perclórico, PCA
About This Item
Productos recomendados
Nombre del producto
Ácido perclórico al 70-72 %, for analysis EMSURE® ACS,ISO,Reag. Ph Eur
grado
ACS reagent
Nivel de calidad
Agency
reag. ISO
reag. Ph. Eur.
Línea del producto
EMSURE®
Formulario
liquid
concentración
70.0-72.0% HClO4
impurezas
≤0.02 ppm Ba (Barium)
≤0.02 ppm Be (Beryllium)
≤0.02 ppm Li (Lithium)
≤0.02 ppm Mn (Manganese)
≤0.02 ppm Sr (Strontium)
≤0.05 ppm Al (Aluminium)
≤0.05 ppm As (Arsenic)
≤0.05 ppm Cd (Cadmium)
≤0.05 ppm Co (Cobalt)
≤0.05 ppm Ge (Germanium)
≤0.05 ppm Mo (Molybdenum)
≤0.05 ppm Pb (Lead)
≤0.05 ppm Tl (Thallium)
≤0.05 ppm V (Vanadium)
≤0.1 ppm Ag (Silver)
≤0.1 ppm Bi (Bismuth)
≤0.1 ppm Cu (Copper)
≤0.1 ppm K (Potassium)
≤0.1 ppm Ni (Nickel)
≤0.1 ppm Ti (Titanium)
≤0.1 ppm Zn (Zinc)
≤0.1 ppm Zr (Zirconium)
≤0.5 ppm Ca (Calcium)
≤0.5 ppm Free chlorine (Cl)
≤0.5 ppm Mg (Magnesium)
≤0.5 ppm Na (Sodium)
≤1 ppm Heavy metals (as Pb)
≤1.0 ppm Fe (Iron)
≤10 ppm Chlorate (ClO3)
≤10 ppm Sulfate (SO4)
≤10 ppm Total nitrogen (N)
≤3 ppm Chloride (Cl)
≤5 ppm Phosphate and Silicate (as SiO2)
residuo de ign.
≤0.003% (as sulfate)
color
APHA: ≤10
cadena SMILES
OCl(=O)(=O)=O
bp
198.7 °C/1013 hPa
mp
-18 °C
solubilidad
water: soluble
densidad
1.68 g/cm3 at 20 °C
temp. de almacenamiento
15-25°C
InChI
1S/ClHO4/c2-1(3,4)5/h(H,2,3,4,5)
Clave InChI
VLTRZXGMWDSKGL-UHFFFAOYSA-N
¿Está buscando productos similares? Visita Guía de comparación de productos
Categorías relacionadas
Aplicación
- Optimización de la modificación por selenilación del polisacárido de ajo en función de su actividad inmunopotenciadora: en este estudio se exploró el proceso de optimización de la selenilación de polisacáridos de ajo, con el objetivo de mejorar sus propiedades inmunopotenciadoras. El ácido perclórico desempeñó un papel en la fase de preparación, facilitando la modificación de los polisacáridos para lograr una mejor bioactividad (Gao et al., 2016).
- Síntesis y caracterización de isodifenilfluorindona e isodifenilfluorindinona: la investigación se centró en la síntesis de nuevos compuestos fluorados, donde se utilizó ácido perclórico como catalizador para promover la formación de estas moléculas complejas, destacando su utilidad en la química orgánica sintética (Zissimou et al., 2018).
- Cocristalización de complejos energéticos fotosensibles de perclorato de cobre(II): se estudió el potencial de los derivados del ácido perclórico para crear materiales fotosensibles estables adecuados para aplicaciones energéticas, demostrando la versatilidad del ácido en la ciencia de los materiales (Evers et al., 2014).
- Biomarcadores moleculares tempranos de estrés oxidativo de penumbra isquémica en el accidente cerebrovascular agudo: en el estudio se utiliza ácido perclórico en la extracción y estabilización de biomarcadores de muestras biológicas, esenciales para el diagnóstico y el tratamiento precisos del accidente cerebrovascular (Lorenzano et al., 2019).
- Ensayo de gran eficacia mejorado para evaluar la actividad anticolinérgica sérica: se desarrolló un nuevo método de análisis utilizando ácido perclórico para extraer y cuantificar la actividad anticolinérgica de muestras de suero, ofreciendo avances para los estudios farmacológicos (Nobrega et al., 2017).
Nota de análisis
Identidad: pasa la prueba
Densidad (d 20/20): aprox. 1,7
Color: ≤ 10 Hazen
Cloratos (ClO₃): ≤ 10 ppm
Cloruros (Cl): ≤ 3 ppm
Cloro libre (Cl): ≤ 0,5 ppm
Fosfatos y silicatos (como SiO₂): ≤ 5 ppm
Sulfatos (SO₄): ≤ 10 ppm
Nitrógeno total (N): ≤ 10 ppm
Metales pesados (como Pb): ≤ 1 ppm
Ag (Plata): ≤ 0,1 ppm
Al (Aluminio): ≤ 0,05 ppm
As(Arsénico): ≤ 0,05 ppm
Ba (Bario): ≤ 0,02 ppm
Be (Berilio): ≤ 0,02 ppm
Bi (Bismuto): ≤ 0,1 ppm
Ca (Calcio): ≤ 0,5 ppm
Cd (Cadmio): ≤ 0,05 ppm
Co (Cobalto): ≤ 0,05 ppm
Cu (Cobre): ≤ 0,1 ppm
Fe (Hierro): ≤ 1,0 ppm
Ge (Germanio): ≤ 0,05 ppm
K (Potasio): ≤ 0,1 ppm
Li (Litio): ≤ 0,02 ppm
Mg (Magnesio): ≤ 0,5 ppm
Mn (Manganeso): ≤ 0,02 ppm
Mo (Molibdeno): ≤ 0,05 ppm
Na (Sodio): ≤ 0,5 ppm
Ni (Níquel): ≤ 0,1 ppm
Pb (Plomo): ≤ 0,05 ppm
Sr (Estroncio): ≤ 0,02 ppm
Ti (Titanio): ≤ 0,1 ppm
Tl (Talio): ≤ 0,05 ppm
V (Vanadio): ≤ 0,05 ppm
Zn (Cinc): ≤ 0,1 ppm
Zr (Circonio): ≤ 0,1 ppm
Residuos tras ignición (como sulfatos): ≤ 0,003 %
Conforme a ACS ACS, ISO, React. Ph Eur
Información legal
Palabra de señalización
Danger
Frases de peligro
Consejos de prudencia
Clasificaciones de peligro
Acute Tox. 4 Oral - Eye Dam. 1 - Met. Corr. 1 - Ox. Liq. 1 - Skin Corr. 1A - STOT RE 2
Órganos de actuación
Thyroid
Código de clase de almacenamiento
5.1A - Strongly oxidizing hazardous materials
Clase de riesgo para el agua (WGK)
WGK 1
Punto de inflamabilidad (°F)
Not applicable
Punto de inflamabilidad (°C)
Not applicable
Certificados de análisis (COA)
Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Los clientes también vieron
Artículos
EMSURE® Grade Inorganic Solvents and Reagents offer exceptional purity and quality control, ensuring reliable, compliant results for regulated analyses.
EMSURE® Grade Inorganic Solvents and Reagents offer exceptional purity and quality control, ensuring reliable, compliant results for regulated analyses.
Protocolos
El ensayo de hierro permite cuantificar los iones de hierro en varios tipos de agua. Los iones de hierro se reducen a iones de hierro (II) que reaccionan con un derivado de la triazina para formar un complejo rojo-violeta que se mide mediante fotometría.
Photometric determination subsequent to acid mineralisation
El ensayo de hierro permite cuantificar los iones de hierro en varios tipos de agua. Los iones de hierro se reducen a iones de hierro (II) que reaccionan con un derivado de la triazina para formar un complejo rojo-violeta que se mide mediante fotometría.
El ensayo de hierro permite cuantificar los iones de hierro en varios tipos de agua. Los iones de hierro se reducen a iones de hierro (II) que reaccionan con un derivado de la triazina para formar un complejo rojo-violeta que se mide mediante fotometría.
Contenido relacionado
Glass bottles are ideal for storing acids because they are inert and offer a long shelf life.
Glass bottles are ideal for storing acids because they are inert and offer a long shelf life.
Glass bottles are ideal for storing acids because they are inert and offer a long shelf life.
Glass bottles are ideal for storing acids because they are inert and offer a long shelf life.
-
How can I determine the shelf life / expiration / retest date of this product?
1 answer-
Helpful?
-
-
How is shipping temperature determined? And how is it related to the product storage temperature?
1 answer-
Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf
Helpful?
-
-
Buongiorno, chiedo se questo prodotto ha una purezza adatta allla preparazione di campioni per l'analisi ICP-OES. Grazie, Matteo
1 answer-
This product may not be suitable for ICP analysis. Please consider product PX0398 for ICP-OES analysis. Please see the link below to review this product option:
https://www.sigmaaldrich.com/US/en/product/mm/px0398Helpful?
-
Active Filters
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico