Saltar al contenido
Merck
Todas las fotos(1)

Documentos clave

40346

Supelco

Dichlorodifluoromethane solution

5000 μg/mL in methanol, certified reference material

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Fórmula empírica (notación de Hill):
CCl2F2
Número de CAS:
Peso molecular:
120.91
Número MDL:
Código UNSPSC:
41116105

grado

certified reference material

Nivel de calidad

CofA

current certificate can be downloaded

envase

ampule of 1 mL

concentración

5000 μg/mL in methanol

técnicas

HPLC: suitable
gas chromatography (GC): suitable

aplicaciones

environmental

Formato

single component solution

temp. de almacenamiento

2-8°C

cadena SMILES

FC(F)(Cl)Cl

InChI

1S/CCl2F2/c2-1(3,4)5

Clave InChI

PXBRQCKWGAHEHS-UHFFFAOYSA-N

¿Está buscando productos similares? Visita Guía de comparación de productos

Aplicación

Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.

Palabra de señalización

Danger

Clasificaciones de peligro

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - Ozone 1 - STOT SE 1

Órganos de actuación

Eyes

Código de clase de almacenamiento

3 - Flammable liquids

Clase de riesgo para el agua (WGK)

WGK 1

Punto de inflamabilidad (°F)

51.8 °F - closed cup

Punto de inflamabilidad (°C)

11 °C - closed cup

Equipo de protección personal

Eyeshields, Faceshields, Gloves


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documentos section.

Si necesita más asistencia, póngase en contacto con Atención al cliente

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Md Azhar Uddin et al.
Chemosphere, 53(9), 1189-1191 (2003-09-27)
Gas-phase reaction of CFC-12 (CCl2F2) with methane was carried out in a plug flow reactor over the temperature range of 873-1123 K. The major organic halocarbons formed during the reaction were C2F4, C2H2F2, CHClF2, CH3Cl, C3H2F6 and CCl3F. The formation
G D Ritchie et al.
Neurotoxicology, 22(2), 233-248 (2001-06-19)
1,1,1,2-Tetrafluoroethane (HFC 134a), a chlorine-free hydrofluoroalkane, is internationally replacing billions of pounds of dichlorodifluoromethane (CFC 12) for coolant, refrigerant and aerosol propellant applications. The ALC50 for HFC 134a in rats is 567,000 ppm for 4 h; its potential for cardiac
Jeong-Myeong Ha et al.
Journal of environmental science and health. Part A, Toxic/hazardous substances & environmental engineering, 46(9), 989-996 (2011-08-19)
The hydrodechlorination of chlorodifluoromethane (HCFC-22) was performed by a catalytic reaction and noncatalytic thermal decomposition at high temperatures of 400-800 °C. After 47 h of time-on-stream on a supported palladium (Pd) catalyst, the gas phase composition of difluoromethane (HFC-32) is
D Chen et al.
Guang pu xue yu guang pu fen xi = Guang pu, 18(3), 319-324 (2005-04-07)
For the management of refractory hazardous wastes, an innovative technology emerging recently is the application of ultra high temperature plasma. The preliminary study on destruction of Freon 12 by ICP (1-2kW) under a joint program between Xiamen Univ. and Hong
Martín González et al.
The Review of scientific instruments, 80(11), 113106-113106 (2009-12-02)
We introduce a beam profiler of pulsed lasers based on the photoacoustic technique. The method assumes that the initial pressure distribution inside the acoustic cell follows the laser intensity pattern if absorbed energy relaxes rapidly. This initial pressure condition can

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico