Saltar al contenido
Merck

25461

Supelco

Columna capilar para GC Carboxen®-1006 PLOT

L × I.D. 30 m × 0.53 mm, average thickness 30 μm

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

UNSPSC Code:
41115710

material

fused silica

description

PLOT = Porous Layer Open Tubular

manufacturer/tradename

Carboxen®

parameter

≤25-250 °C temperature (isothermal or programmed)

average thickness

30 μm

df

30 μm

technique(s)

gas chromatography (GC): suitable

L × I.D.

30 m × 0.53 mm

matrix active group

Carbon molecular sieve phase

application(s)

chemicals and industrial polymers
food and beverages

column type

capillary PLOT

¿Está buscando productos similares? Visita Guía de comparación de productos

General description

El adsorbente Carboxen® se utiliza idealmente para microextracción en fase sólida (SPME) y permite una extracción eficiente de moléculas polares pequeñas de una disolución acuosa. Las columnas tubulares abiertas de capa porosa (PLOT) son una potente herramienta que se utiliza para analizar gases fijados, hidrocarburos ligeros y disolventes volátiles en métodos de cromatografía de gases. En su mayoría, se prefieren a las columnas rellenas tradicionales.
Aplicación: Esta columna es ideal para la separación de muchos componentes gaseosos permanentes (como helio, hidrógeno, nitrógeno, monóxido de carbono, metano y dióxido de carbono) e hidrocarburos ligeros (C2-C3) en el mismo análisis. Es ideal para resolver mezclas de formaldehído/agua/metanol (formol) y controlar las impurezas en etileno. Esta columna se puede utilizar con caudales elevados y programas de temperatura rápidos para garantizar separaciones excelentes y rápidas.
Código USP: Ninguna
Fase:
  • Tamiz molecular de carbono
Temperatura Límites:
  • Desde debajo de la temperatura ambiente hasta 250 °C (isotérmica o programada)

Other Notes

Ofrecemos una gran variedad de accesorios para cromatografía, entre ellos jeringas analíticas

Legal Information

Carboxen is a registered trademark of Merck KGaA, Darmstadt, Germany

Storage Class

11 - Combustible Solids

wgk_germany

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Los clientes también vieron

Slide 1 of 1

1 of 1

Applications of Solid Phase Microextraction
Pawliszyn J.
Applications of Solid Phase Microextraction, 64-65 (1999)
Porous layer open-tubular capillary columns: preparations, applications and future directions.
Zhenghua Ji
Journal of Chromatography A, 842 (1), 115-142 (1999)
Louise Urruty et al.
Journal of agricultural and food chemistry, 50(11), 3129-3136 (2002-05-16)
To provide an efficient and running analytical tool to strawberry plant breeders who have to characterize and compare the aromatic properties of new cultivars to those already known, a HS-SPME/GC-MS analysis method has been coupled with a statistical treatment method
Noushin Rastkari et al.
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 877(14-15), 1568-1574 (2009-04-28)
Carbon nanotubes (CNTs) are a kind of new carbon-based nano-materials which have drawn great attention in many application fields. The potential single-walled carbon nanotubes (SWCNTs) as solid-phase microextraction (SPME) adsorbents for the preconcentration of environmental pollutants have been investigated in
Julien Januszkiewicz et al.
Journal of chromatography. A, 1195(1-2), 16-24 (2008-05-23)
A headspace solid-phase microextraction (HS-SPME) combined with gas chromatography-mass spectrometry (GC/MS) method was developed using experimental designs to quantify the flavor of commercial Cheddar cheese and enzyme-modified Cheddar cheese (EMCC). Seven target compounds (dimethyl disulfide, hexanal, hexanol, 2-heptanone, ethyl hexanoate

Protocolos

Separation of Methane; Acetylene; Carbon monoxide; Water; Nitrogen; Carbon dioxide; Ethane; Ethylene

Contenido relacionado

Complete offer for petrochemical testing including environmental and industrial hygiene monitoring solutions.

Complete offer for petrochemical testing including environmental and industrial hygiene monitoring solutions.

Complete offer for petrochemical testing including environmental and industrial hygiene monitoring solutions.

Complete offer for petrochemical testing including environmental and industrial hygiene monitoring solutions.

Chromatograms

suitable for GC

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico