Saltar al contenido
Merck

FITC1

Sigma-Aldrich

FluoroTag FITC Conjugation Kit

Sinónimos:

FITC

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

UNSPSC Code:
12352200
NACRES:
NA.32
En este momento no podemos mostrarle ni los precios ni la disponibilidad

packaging

pkg of (Kit contains reagents for 5 conjugations.)

Quality Level

fluorescence

λex 495 nm; λem 525 nm

storage temp.

2-8°C

Application

The Flourotag FITC Conjugation Kit can be used for Immunohistochemisty and Immunocytochemistry using Flow Cytometry. It is also be used for the conjugation of FITC to peptide hormones, cytokines, growth factors and proteins.

Features and Benefits

  • Suitable for both small (1 mg) and large (5 mg) scale conjugations
  • Completely aqueous procedure - no DMF needed
  • Fast gel filtration separation of conjugate from excess FITC
  • Complete protocols for conjugation and F/P ratio determination
  • Sufficient reagents for at least 5 conjugations of 5 mg protein each and for optimization of F/P ratio before scale-up
  • References for applications and protocols

Principle

Sigma offers a convenient kit for preparing FITC-labeled antibodies. Fluorescein isothiocyanate (FITC), Isomer 1, is a widely used fluorophore, popular because of its high quantum efficiency and stability when conjugated. FITC is yellow-orange in color with an absorption maximum at 495 nm. Upon excitation it emits a yellow-green color with an emission maximum at 525 nm. Conjugation occurs through free amino groups of proteins or peptides, forming a stable thiourea bond (see reaction). FITC conjugates of antibodies, lectins, hormones, and growth factors have been used in a variety of immunohistochemical and flow cytometry applications. The protocols have been optimized for antibodies, but may be adapted to other proteins by the end user.

Analysis Note

Procedure
1. Dissolve protein and FITC in carbonate-bicarbonate buffer.
2. Slowly add FITC to protein with stirring. Cover with foil and stir 2 hours at room temperature.
3. Separate conjugate from free FITC on G-25 column. Collect fractions.
4. Pool fractions containing conjugate.
5. Determine F/P ratio of conjugate spectrophotometrically.
6. Stabilize with 1% bovine serum albumin and 0.1% sodium azide and store at 0-5 °C.

Legal Information

FluoroTag is a trademark of Sigma-Aldrich Co. LLC

Solo componentes del kit

Referencia del producto
Descripción

  • Sephadex G-25 column, 3.5 mL 1

  • Sephadex G-25 column, 9.1 mL 1

  • Fluorescein isothiocyanate isomer I - F7250KC-2MG 2 mg

Los componentes del kit también están disponibles por separado

Referencia del producto
Descripción
SDS

  • P3813Phosphate buffered saline, powder, pH 7.4, for preparing 1 L solutions 5 pkgSDS

related product

Referencia del producto
Descripción
Precios

pictograms

Exclamation mark

signalword

Warning

hcodes

Hazard Classifications

Eye Irrit. 2

Storage Class

10 - Combustible liquids

flash_point_f

Not applicable

flash_point_c

Not applicable


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

P F Blackmore
Steroids, 64(1-2), 149-156 (1999-05-14)
Progesterone rapidly increased intracellular free calcium ([Ca2+]i) in human sperm, removal of extracellular Ca2+ prevented the increase in [Ca2+]i. The Ca2+ influx was not blocked by the T-type Ca2+ channel blocker mibefradil. However T-type calcium channels do appear to be
Sunali Bhatnagar et al.
Journal of controlled release : official journal of the Controlled Release Society, 238, 22-30 (2016-07-16)
Inertial cavitation mediated by ultrasound has been previously shown to enable skin permeabilisation for transdermal drug and vaccine delivery, by sequentially applying the ultrasound then the therapeutic in liquid form on the skin surface. Using a novel hydrogel dosage form
R F Mullins et al.
Ophthalmology, 104(2), 288-294 (1997-02-01)
Drusen are extracellular deposits that accumulate between the basal lamina of the retinal pigment epithelium and the elastic lamina of Bruch membrane in aging human eyes. Although specific types of drusen are recognized as significant risk factors for the development
H Hidaka et al.
Journal of lipid research, 40(6), 1131-1139 (1999-06-05)
We previously reported the identity and purification of two HDL3-binding proteins in rat liver plasma membranes. As these proteins are candidate high density lipoprotein (HDL) receptors and probably multifunctional, including a role in HDL metabolism, we have considerable interest in
Erhao Zhang et al.
Journal of hematology & oncology, 11(1), 44-44 (2018-03-22)
Chimeric antigen receptors (CARs) presented on T cell surfaces enable redirection of T cell specificity, which has enormous promise in antitumor therapy. However, excessive activity and poor control over such engineered T cells cause significant safety challenges, such as cytokine

Questions

1–6 of 6 Questions  
  1. I would like to inquire about the sensitivity, limit of detection (LOD), and limit of quantification (LOQ) for the FluoroTag™ FITC Conjugation Kit. Thank you.

    1 answer
    1. Conjugation with FITC occurs through free amino groups of proteins or peptides. The F/P molar ratio of the conjugate, as well as the limit of detection, will vary from one protein to another and must be determined empirically by the end user. Please access the Product Information Sheet in the DOCUMENTATION section of the Product Detail Page under the 'Product Information Sheet' tab for further details.

      Helpful?

  2. Can Product FITC1, FluoroTag™ FITC Conjugation Kit, be used with antibodies at concentrations less than 5 mg/mL?

    1 answer
    1. You can scale down the reaction for labeling.  A possible problem occurs in using the column to remove the free FITC.  If the volume is too small, the column cannot be used.  We would recommend using dialysis to remove the free (unconjugated) FITC.

      Helpful?

  3. My antibody is in solution containing azide.  Can I use the antibody directly in the reaction when using Product FITC1, FluoroTag™ FITC Conjugation Kit?

    1 answer
    1. It is not recommended to have azide in the reaction mix. If the buffer contains amines or sodium azide, dialyze protein solution (1 mL) against PBS, pH 7.4 (approximately 1000 mL), overnight at 2-8 °C.

      Helpful?

  4. When using Product FITC1, FluoroTag™ FITC Conjugation Kit, should I adjust the dye:protein ratio for the size of the protein being labeled?

    1 answer
    1. Adjustments for dye/protein ratios should only be made for very small proteins, i.e. < 25 kDa. Here, you should use less protein per dye portion. In many cases, this weight amount of protein is IgG with MW 150 kDa, and the kit would provide a molar excess of dye to provide attachment of a few dyes per IgG. If one wants to attempt labeling of a very small protein using the same weight ratio, there is a good chance there would not be enough dye/protein.

      Helpful?

  5. Can the columns in Product FITC1, FluoroTag™ FITC Conjugation Kit, be reused?

    1 answer
    1. Wash the column with 35 ml (10 X column volumes) of PBS to remove unbound fluorophore. This is sufficient to regenerate the column.  For prolonged storage, wash the column with 10 mL of PBS containing 0.05% sodium azide and store capped at 2-8 °C, with about 1 mL buffer above the gel.

      Helpful?

  6. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?

Reviews

No rating value

Active Filters

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico