Saltar al contenido
Merck
Todas las fotos(1)

Key Documents

SCT280

Sigma-Aldrich

BioTracker Far Red Live Cell Cycle Assay Solution

Human

Sinónimos:

cell cycle dye, cell cycle indicator, cell cycle probe, live cell probe

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

UNSPSC Code:
41106514
NACRES:
NA.47

product name

BioTracker Far Red Live Cell Cycle Assay Solution,

biological source

human

Quality Level

packaging

vial of 50 tests

manufacturer/tradename

Millipore

technique(s)

cell culture | stem cell: suitable
flow cytometry: suitable

shipped in

dry ice

storage temp.

−20°C

General description

Propidium iodide (PI) is often used for cell cycle analysis by flow cytometry. Compared to this analysis method, the BioTracker Far Red Live Cell Cycle Assay Solution does not require cell fixation or permeabilization, and is permeable in live cells. Use 5 uL of probe solution in 500 uL PBS for each sample. Vial contains enough for 50 tests.The far red probe uses the 633 laser, enabling multiplexing with shorter wavelength probes by freeing the 488 laser for probes that emit in the green range of the spectrum. IMPORTANT APPLICATION NOTES:*Wash cells thoroughly to remove trypsin. Residual trypsin can confound analysis of flow cytometry populations.*Adjust gates after cells are stained with probe SPECTRAL PROPERTIESExcitation: 633 - 647 nmEmission: 695 LP or 780/60 BP.A filter set for APC-Cy7 is suitable.

Features and Benefits

Far red fluorescence probe for analysis of cell cycle by flow cytometry.

Target description

The control system of the cell cycle is closely linked to cell proliferation. Cell division in which one cell produces two daughter cells occurs as part of the cell cycle. The cell cycle can be assessed by analyzing cells stained for DNA using flow cytometry, followed by analysis of the proportion of stained nuclei in cell cycle phase. The cell cycle is classified into two major phases: interphase and the mitotic (M) phase. Interphase is composed of G1 phase (preparation for DNA synthesis which occurs prior to cell division), S phase (DNA synthesis and replication), and G2 phase (a single cell with duplicated chromosomes). M phase involves mitosis and cytokinesis. Cell cycle progression is regulated by cyclins and cyclin-dependent kinases. To determine the action of anticancer drugs and others, it is important to analyze the mechanism of cell-cycle checkpoint.

Storage and Stability

Store BioTracker Far Red Live Cell Cycle Assay Solution at -20 °C, protected from light.

Other Notes

Live cell probe for fluorescent cell cycle analysis. Unlike propidium iodide, this probe is membrane permeable and highly specific for DNA, which makes it possible to analyze the cell cycle by simply adding the reagent to a cell suspension.

Legal Information

BioTracker is a trademark of Merck KGaA, Darmstadt, Germany

Disclaimer

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

pictograms

CorrosionEnvironment

signalword

Danger

hcodes

Hazard Classifications

Aquatic Chronic 2 - Eye Dam. 1

Storage Class

10 - Combustible liquids

wgk_germany

WGK 3


Certificados de análisis (COA)

Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico