1.52270
Chromolith® WP 300 RP-18 (monolithic) HPLC Columns
L × I.D. 100 mm x 4.6 mm HPLC Column
Sinónimos:
Chromolith® WP 300 RP-18 100-4.6 HPLC column
About This Item
Productos recomendados
product name
Chromolith® WP 300 RP-18, L × I.D. 100 mm x 4.6 mm HPLC column
material
PEEK column
Quality Level
agency
suitable for USP L1
product line
Chromolith®
feature
endcapped: no
endcapped: no
packaging
1 ea of
extent of labeling
18% Carbon loading
18% loading
parameter
200 bar pressure
200 bar pressure
60 °C max. temp.
60 °C max. temp.
technique(s)
HPLC: suitable
HPLC: suitable
LC/MS: suitable
mass spectrometry (MS): suitable (High)
mass spectrometry (MS): suitable
column L × I.D.
10 cm × 4.6 mm
surface area
300 m2/g
matrix
monolithic silica
monolithic silica
matrix active group
C18 bonding phase
C18 bonding phase
pore size
2 μm macroporosity
2 μm macroporosity
30 mm mesoporosity
30 nm mesoporosity
operating pH range
1.5-7.5
2-7.5
separation technique
reversed phase
storage temp.
no temp limit
¿Está buscando productos similares? Visita Guía de comparación de productos
Categorías relacionadas
General description
Accurate analysis of proteins, antibodies, and large peptides requires columns with good permeability, along with better mass transfer and selectivity. In order for size-exclusion not to influence the separation, the pore size should be approximately ten times larger than the molecule being analyzed.
Chromolith columns have shown great potential and superiority in comparison to standard silica. Chromolith® WP 300 columns are made of monolithic silica with a characteristic bimodal pore structure.
Chromolith® WP 300 RP-18 columns have macropores with 2 μm diameter, giving a column efficiency exceeding 80,000 plates/meter. The mesopores are 30 nm (300 Å), and the surface modification is Octadecylsilane.
Chromolith® WP 300 RP-18 columns fall under the USP L1 Classification. The column efficiency is comparable to a 5 μm particle size fully porous particulate column. Chromolith® WP 300 RP-18 columns are suitable for LC-MS applications.The column dimension of 100 mm in length and 4.6 mm I.D. is the best choice for fast separations of Biomolecules on any HPLC System.Chromolith® WP 300 RP-18 100-4.6 HPLC columns enable:
- Completely bioinert column hardware and high biorecovery
- High-speed separations at very low column back-pressure
- High matrix tolerance, allowing time and cost savings with simplified workflows
- Cost savings due to extended column lifetimes
- Connection of columns, flow gradients, and the use of mobile phases with higher viscosity
Legal Information
Certificados de análisis (COA)
Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Contenido relacionado
La cromatografía de líquidos de alta resolución (HPLC) puede utilizarse para separar e identificar diferentes biomoléculas grandes, como proteínas y péptidos, en una muestra. Se basa en el bombeo de una muestra con un disolvente (fase móvil) a través de una columna rellena con material absorbente (fase estacionaria) a una presión elevada.
La cromatografía de líquidos de alta resolución (HPLC) puede utilizarse para separar e identificar diferentes biomoléculas grandes, como proteínas y péptidos, en una muestra. Se basa en el bombeo de una muestra con un disolvente (fase móvil) a través de una columna rellena con material absorbente (fase estacionaria) a una presión elevada.
HPLC separates and identifies large biomolecules like proteins and peptides by pumping the sample through a sorbent-packed column.
HPLC separates and identifies large biomolecules like proteins and peptides by pumping the sample through a sorbent-packed column.
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico